PubMed Health⌕ Search

Biomedical subjects

A A Carneiro

Publications and source records attributed to A A Carneiro.

2 recordsLinked to original sources

In vivo tissue characterization using magnetic techniques.

Among the few non-invasive methods to quantify liver iron deposits, magnetic resonance imaging (MRI) and biomagnetic liver susceptometry (BLS) have been considered the best to evaluate iron overload in the body. This diagnosis is necessary for patients who regularly receive red blood cells transfusion and that have a genetic disorder known as hemochromatosis. In this work, we present the evaluation of the clinical usefulness of MRI and BLS of hepatic tissue to quantify iron deposits in non-transfused and transfused patients. Liver iron evaluation by MRI and BLS were performed in a group of 48 patients. The MRI images weighted in T2 were acquired using multi-slice single-spin-echo (SSE) and single-slice multi-spin-echo (MSE), conducted on a 1.5 T whole body scanner. BLS measurements were performed using an ac superconducting susceptometer based on SQUID. Typically MRI is able to evaluate iron overload in liver as high as 30 mg/g(dry tissue) when using MRI scanners provided with specially designed pulse sequences. For higher iron concentrations susceptibility measurement works better than MRI to evaluate higher iron overloads in the liver, because in this case there is saturation of MRI signal.

Adolescent↗

Study of stomach motility using the relaxation of magnetic tracers.

Magnetic tracers can be observed in the interior of the human body to give information about their quantity, position and state of order. With the aim of detecting and studying the degree of disorder of these tracers after they have been previously magnetized inside the stomach, a system composed of magnetization coils and magnetic detectors was developed. Helmholtz coils of diameter 84 cm were used to magnetize the sample and the remanent magnetization (RM) was detected with two first-order gradiometric fluxgate arrays each with a 15 cm base line, sensitivity of 0.5 nT and common mode rejection (CMR) of at least 10. The system allows simultaneous measurement in the anterior and posterior projections of the stomach. Measurements of the time evolution of the RM were performed in vitro and in normal subjects after the ingestion of a test meal labelled with magnetic particles. The data were fitted with an exponential curve and the relaxation time tau was obtained. Initial studies were performed to ascertain the action of a drug that is known to affect the gastric motility, showing that the decay of the remanent magnetization was indeed due to stomach contractions.

Butylscopolammonium Bromide↗