PubMed Health⌕ Search

Biomedical subjects

A A Mehdirad

Publications and source records attributed to A A Mehdirad.

20 records · Page 2Linked to original sources

Radiofrequency catheter ablation of atrioventricular accessory pathways in 3 dogs with subsequent resolution of tachycardia-induced cardiomyopathy.

Incessant supraventricular tachyarrhythmias are known to result in myocardial dysfunction indistinguishable from idiopathic dilated cardiomyopathy by current testing methods. This tachycardia-induced cardiomyopathy (TICM), however, is uniquely reversible with adequate rhythm control. Two dogs were presented to The Ohio State University for incessant supraventricular tachycardia (SVT) and echocardiographic signs of dilated cardiomyopathy, later proven to be TICM. A 3rd dog presented for frequent paroxysms of SVT and syncope had echocardiographic signs of mild myocardial systolic dysfunction. All 3 dogs had inadequate rhythm control with multiple antiarrhythmic agents, and 1 dog suffered from recurrent left-sided congestive heart failure. Generalized cardiomegaly was found in 1 dog and left-sided dilatation without concurrent right-sided enlargement in 1 dog. Mild-to-severe left ventricular systolic dysfunction was confirmed echocardiographically in all dogs. A total of 4 atrioventricular accessory pathways (APs) were found during invasive electrophysiologic studies in these 3 dogs. All APs were successfully ablated with radiofrequency energy delivered through a thermistor-tipped catheter. Elimination of AP conduction, and thus orthodromic atrioventricular reciprocating tachycardia, resulted in resolution of all clinical and echocardiographic evidence of TICM in these dogs. This result confirms that the cardiomyopathy was, in fact, reversible TICM. All cardiovascular medications were discontinued, and no complications occurred during a 15-25-month follow-up period.

Animals↗

Drug and defibrillator interactions.

We reviewed the interactions of drugs and defibrillators, with emphasis on implantable cardioverter defibrillators. Articles were identified by searching MEDLINE from 1966 to the present; additional sources were identified from reference lists in these articles. Drugs have the potential for both beneficial and harmful interactions with electrical therapy. Beneficial interactions include reductions in the energy required to defibrillate the heart and in the occurrence of arrhythmia resulting in decreased shock frequency, prolonged device longevity, and improved patient comfort. Potentially harmful interactions include altering the detection of ventricular tachycardia; altering the pacing threshold, resulting in interference with bradycardia or antitachycardia pacing; development of incessant ventricular tachycardia; and increasing the energy required to defibrillate the heart. As the use of implantable cardioverter defibrillators increases, pharmacists should be aware of the potential for drug-device interactions.

Animals↗