PubMed Health⌕ Search

Biomedical subjects

A A Wallman

Publications and source records attributed to A A Wallman.

6 recordsLinked to original sources

Rapid diagnosis of pulmonary tuberculosis by using Roche AMPLICOR Mycobacterium tuberculosis PCR test.

A rapid PCR-based test for the diagnosis of pulmonary tuberculosis, the Roche AMPLICOR Mycobacterium tuberculosis test (AMPLICOR MTB), was evaluated. Results from AMPLICOR MTB were compared with culture results and the final clinical diagnosis for each patient. A total of 985 specimens from 372 patients were tested. When AMPLICOR MTB results were compared with resolved results, i.e., a specimen grew M. tuberculosis or was obtained from a patient with a clinical diagnosis of tuberculosis, the sensitivity, specificity, positive predictive value, and negative predictive value for the AMPLICOR MTB test were 66.7, 99.6, 91.7, and 97.7%, respectively. These results were comparable to those obtained from culture. Test results were available approximately 6.5 h after specimen receipt in the laboratory. Our data demonstrate that AMPLICOR MTB will provide rapid, valuable information for the diagnosis and control of tuberculosis.

Bacteriological Techniques↗

Neisseria sicca endocarditis with embolic phenomena.

Two patients with poor oral hygiene developed Neisseria sicca endocarditis, one after probable intravenous drug abuse and Staphylococcus aureus endocarditis and the other after a periodontal surgical procedure. Both experienced significant embolic phenomena and both required 6 or more weeks of intravenous antibiotic therapy. The diagnosis of N. sicca endocarditis must be considered when this organism is isolated from blood cultures in patients with emboli.

Adult↗

Quantitative antimicrobial susceptibility test for Streptococcus pneumoniae using inoculum supplemented with whole defibrinated sheep blood.

The National Committee for Clinical Laboratory Standards recommends the use of lysed horse blood-supplemented Mueller-Hinton broth for determining the quantitative antimicrobial susceptibility of Streptococcus pneumoniae. This procedure may be difficult for laboratories using previously prepared or commercial MIC systems. Therefore, a study was undertaken to determine whether previously prepared microdilution trays containing Mueller-Hinton broth without blood could be used for determining the antimicrobial susceptibility of S. pneumoniae by adding whole defibrinated sheep blood to the bacterial suspension used to inoculate the trays. The presence of alpha-hemolysis was used as an indicator of bacterial growth. One hundred isolates of S. pneumoniae selected to represent a distribution of susceptibility patterns were tested by the National Committee for Clinical Laboratory Standards method and the sheep blood-supplemented-inoculum method. Greater than 94% agreement between the two methods was achieved. The sheep-blood-supplemented-inoculum procedure was highly reproducible and easy to perform and provides an acceptable alternative for determining the MICs for S. pneumoniae for laboratories using previously prepared or commercial microdilution systems.

Culture Media↗

Two fatal cases of type E adult food-borne botulism with early symptoms and terminal neurologic signs.

Type E botulism, one of the least common forms of botulinal intoxication on the East Coast of the United States, is described for two elderly patients with chronic underlying disease. Both patients consumed tainted kapchunka, a salted, ungutted whitefish. Gastrointestinal symptoms and signs were prominent, but neurologic complaints, although noted soon after the consumption of the fish in one patient, did not progress until late in the course of the patient's illness. One patient exhibited both urinary retention, which was reported mainly in one outbreak of type E botulism (M.G. Koenig, A. Spickard, M.A. Cardella, and D.E. Rogers, Medicine [Baltimore] 43:517-545, 1964), and muscular fasciculations, which have been rarely reported.

Animals↗

Evaluation of the BIOGRAM antimicrobial susceptibility test system.

BIOGRAM is an antimicrobial susceptibility test system for the determination of MICs from the standard disk diffusion test zone diameters. The system was challenged with 511 recent clinical isolates of members of the family Enterobacteriaceae, nonfermentative gram-negative bacteria, staphylococci, and enterococci. Results were compared with those obtained with the broth microdilution method. Appropriate control organisms were included with each test series. A total of 10,085 organism-drug combinations were evaluated. BIOGRAM demonstrated an overall correlation of 95.9% with the reference broth microdilution method.

Anti-Bacterial Agents↗