PubMed Health⌕ Search

Biomedical subjects

A Agüera

Publications and source records attributed to A Agüera.

18 recordsLinked to original sources

LC-MS analysis and environmental risk of lipid regulators.

This article presents a review of liquid chromatography-mass spectrometric (LC-MS) methods applied to the determination of lipid-regulating agents, "fibrate" and "statin" classes, and some of their metabolites (clofibric acid and fenofibric acid) in environmental samples. Concentration levels of this therapeutical group have been reported in the ppt to ppb range for different compartments (wastewater, surface water and sediments) in several monitoring studies. Part of this article is dedicated to hazard assessment of lipid-regulating agents according to the approaches of the European Union (EU) and Environmental Protection Agency (EPA) for identifying persistent, bioaccumulable and toxic (PBT) substances. The pharmacodynamic and pharmacokinetic activities of these pharmaceuticals are well known and, based on this information, the derivation of the potential long-term effects, which may be induced on eco-organisms at low concentration levels, is discussed. Studies of environmental risk assessment (ERA) for lipid regulators carried out through the framework of the European Agency for the Evaluation of Medicinal Products (EMEA) and Food and Drug Administration (FDA) are presented.

Animals↗

Pilot survey monitoring pharmaceuticals and related compounds in a sewage treatment plant located on the Mediterranean coast.

A one-year monitoring study was performed to evaluate the occurrence, persistence and fate of a group of 14 organic compounds in a sewage treatment plant (STP) located in the south of Spain. These results are part of a more extensive study, financed by the Spanish Ministry of Research with the aim to evaluate the traceability of new pollutants on the Mediterranean coast and to determine the removal efficiency of sewage treatment plants (STP) for these pollutants. The compounds which have been analyzed include pharmaceuticals of various therapeutic categories (ibuprofen, acetaminophen, dipyrone, diclofenac, carbamazepine and codeine), pesticides (chlorfenvinfos and permethrin), caffeine, triclosan, bisphenol A and three of their more relevant metabolites (1,7-dimethylxanthine, carbamazepine 10,11-epoxide and 2,7/2,8-dichlorodibenzo-p-dioxin). An SPE/GC-MS multi-residue analytical method was developed and validated to facilitate simultaneous determination of these compounds in both influent and effluent wastewater. The method provided mean recoveries higher than 75%, with the exception of 2,7/2,8-dichlorodibenzo-p-dioxin, dipyrone and permethrin which exhibited recoveries lower than 22%. The overall variability of the method was below 14%. The method detection limit (LOD) was between 1 and 100 ng l(-1) and precision, which was calculated as relative standard deviation (RSD), ranged from 1.8% to 11.2%. The application of the proposed method has allowed the identification of all the target compounds at mean concentrations which ranged from 0.12 to 134 microg l(-1) in the influent and from 0.09 to 18.0 microg l(-1) in the effluent. The removal efficiencies of the STP for these compounds varied from 20% (carbamazepine) to 99% (acetaminophen), but in all cases resulted insufficient in order to avoid their presence in treated water and subsequently in the environment.

Environmental Monitoring↗

Application of gas chromatography-hybrid chemical ionization mass spectrometry to the analysis of diclofenac in wastewater samples.

Hybrid chemical ionization (HCI), a new and useful alternative to conventional chemical ionization mass spectrometry, has been applied to the analysis of the pharmaceutical diclofenac in wastewater samples. This technique takes advantage of the high versatility of ion trap (IT) spectrometers combined with external ionization sources. In hybrid configuration, reagent ions are generated in the external source through electron ionisation (EI) of a reagent gas. These reagent ions are then drawn into the ion trap and only those selected are allowed to react with analytes eluting from the GC column. These ion-molecule reactions create analyte ions which are held in the ion trap. In this study ion-molecule reactions between C(3)F(5)(+) cations, generated from perfluorotributylamine (FC43), and diclofenac molecules have been investigated. The observed reaction products were [M+C(3)F(5)-H(2)O](+) adduct ions, which result from the initial electrophilic addition of C(3)F(5)(+) cations to the diclofenac molecule followed by the rapid loss of H(2)O. Further fragmentation of these ions by MS/MS yielded enough daughter ions for a reliable identification of diclofenac in complex matrices. The GC-HCI-MS/MS method applied to wastewater samples provided highly enhanced selectivity and sensibility, with a detection limit in real samples of 3.0 ng/L, for a solid-phase extraction (SPE) pre-concentration factor of 400. Other performance characteristics of the method, such as linearity and precision were also satisfactory. Finally, the method was successfully applied to the analysis of wastewater samples taken from the effluent of an urban sewage treatment plant (STP).

Chromatography, Gas↗

Application of time-of-flight mass spectrometry to the analysis of phototransformation products of diclofenac in water under natural sunlight.

Exact mass capabilities of time-of-flight (TOF) mass spectrometry along with other mass spectrometric techniques have been evaluated to elucidate a complete range of dichlofenac phototransformation products. Photolysis experiments with diclofenac in water under direct solar irradiation were performed to characterise the main phototransformation products generated and to determine their stability. Photolysis experiments were performed in both demineralised water and reconstructed standard freshwater. Samples were extracted before analysis by solid phase extraction (SPE) with Oasis HLB and MAX cartridges. Separation and identification of the transformation products were accomplished by the combined use of gas chromatography-mass spectrometry (GC/MS) and liquid chromatography coupled with time-of-flight mass spectrometry (LC/TOFMS). Both techniques provided complementary information that enabled the identification of 13 phototransformation products. Six of them were identified by GC/MS through the structural information provided by the full scan mass spectra obtained under electron impact (EI) ionisation and the confirmation of the molecular mass provided by positive chemical ionisation (PCI) analyses. Accurate mass measurements obtained by LC/TOFMS provided the elucidation of seven polar transformation products. The low mass error observed (<2 ppm) enabled the assignment of highly probable empirical formulas as well as identification of a process dimerisation route. The photoproducts identified demonstrated that photolysis of diclofenac occurs by two main routes. One is the consequence of the initial photocyclisation of diclofenac into carbazole derivatives. The other route goes through the initial decarboxilation of diclofenac and further oxidation of the alkyl-chain, which are typical photolytic process reactions. The main photoproduct identified was 8-chloro-9H-carbazole-1yl-acetic acid.

Anti-Inflammatory Agents, Non-Steroidal↗

Comparative study of analytical methods involving gas chromatography-mass spectrometry after derivatization and gas chromatography-tandem mass spectrometry for the determination of selected endocrine disrupting compounds in wastewaters.

Two GC-MS methods, based on the application of N,O-bis(trimethylsilyl)trifluoroacetamide-derivatization-GC-MS (selected-ion monitoring) and GC-MS-MS without derivatization, respectively, were optimised and applied to the determination of a group of five selected endocrine disrupting compounds (EDCs) in wastewaters. Both methods included solid-phase extraction with Oasis HLB cartridges allowing an enrichment factor for wastewater samples of 100-fold. The investigated EDCs were estrone, 17beta-estradiol, 17alpha-ethynylestradiol, 4-tert-octylphenol and bisphenol A. Results obtained from the validation studies yielded comparable results in both cases. Recoveries in spiked wastewaters at 50 ng/l were higher than 90% for all the compounds, except for 4-tert-octylphenol (75%). Repeatability and reproducibility were adequate, varying from 1.6 to 14%, except for estrone which reproducibility was 28% when the derivatization-GC-MS method was applied. Limits of detection calculated ranged from 2.5 to 27.5 ng/l with differences between both methods from 1.1 (estrone) to 10.4 (bisphenol A) times. Both methods were successfully applied to the analysis of the target compounds in sewage treatment plant influents and effluents. Traces of bisphenol A, 4-tert-octylphenol, estrone and 17beta-estradiol were detected at concentration levels ranging from 13.3 to 1105.2 ng/l.

Endocrine Glands↗

Photocatalytic treatment of diuron by solar photocatalysis: evaluation of main intermediates and toxicity.

The technical feasibility, mechanisms, and performance of degradation of aqueous diuron (22 mg/L) have been studied at pilot scale in two well-defined photocatalytic systems of special interest because natural UV light can be used: heterogeneous photocatalysis with titanium dioxide and homogeneous photocatalysis by photo-Fenton. Equivalent pilot-scale (made up of Compound Parabolic Collectors (CPCs) specially designed for solar photocatalytic applications) and field conditions used for both allowed adequate comparison of the degree of mineralization and toxicity achieved as well as the transformation products generated en route to mineralization by both systems. Total disappearance of diuron is attained by both phototreatments in 45 min. 100% of chlorine was recovered as chloride, but total recovery of nitrogen as inorganic ions was not attained. 90% of mineralization was reached after 200 min of photocatalytic treatment, but toxicity measured by two different bioassays (Daphnia magna and a Microalga) was reduced to below the threshold (EC50%) in a shorter time. Transformation products evaluated by LC-IT-MS by direct injection of the samples were the same in both cases. The main differences between the two processes were in the amount of transformation products (DPs) generated, not in the DPs detected, which were always the same.

Animals↗

Toxicity assays: a way for evaluating AOPs efficiency.

The technical feasibility and performance of photocatalytic degradation of aqueous methomyl (50 mg/L) have been studied at pilot scale in two well-defined systems of special interest because natural-solar UV light can be used: heterogeneous photocatalysis with titanium dioxide and homogeneous photocatalysis by photo-Fenton. The pilot plant is made up of compound parabolic collectors specially designed for solar photocatalytic applications. Experimental conditions allowed pesticide disappearance, degree of mineralisation and toxicity achieved in the two photocatalytic systems to be compared. Total disappearance of methomyl is attained by photo-Fenton in 60 min and by TiO2 in 100 min. Hundred percent of nitrogen and sulphur are recovered as ammonium and sulphate. By contrast, complete mineralisation of total organic carbon (TOC) is not achieved even after quite a long time (more than 300 min). Three different bioassays (Vibrio fischeri, Daphnia magna and a Microalga) have been used for testing the progress of toxicity during treatment. All remained toxic down to very low-pesticide concentrations and in some bioassays were still toxic after total disappearance of the pesticide. Only if treatment is maintained throughout enough mineralisation (i.e. TOC disappearance), the toxicity is reduced to below the threshold (EC50%).

Animals↗

Determination of traces of five antifouling agents in water by gas chromatography with positive/negative chemical ionisation and tandem mass spectrometric detection.

A highly selective and sensitive gas chromatography-mass spectrometry methodology has been developed for the determination of five antifouling compounds, currently licensed for use in marine antifouling paints. The procedure uses an ion trap mass spectrometer provided with an external ion source that allows the combined use, in the same analysis, of positive (PCI) and negative (NCI) chemical ionisation and tandem mass spectrometric fragmentation (MS-MS). Ionisation and fragmentation processes were optimised individually for each compound, thus, permitting maximum sensitivity and selectivity to be obtained. A complete validation study, including those aspects that affect both correct quantification and unequivocal confirmation, demonstrated the good performance of the proposed method. Detection limits obtained were lower than 0.005 microg l(-1), except for Irgarol 1051 (0.050 microg l(-1)). The method was applied to real seawater samples from different

Fungicides, Industrial↗

Use of porous graphitic carbon coupled with mass detection for the analysis of polar phenolic compounds by liquid chromatography.

Phenolic compounds present in olive mill wastewater (OMW) need to be quantified because of their pollution capacity toward the environment. In the present study, six representative phenolic compounds of OMW were chosen to develop a LC-MS method. The high polarity of the compounds caused problems when using traditional reversed-phase liquid chromatography (RPLC). Consequently, a method was developed on another kind of chromatographic phase: Porous Graphitic Carbon (PGC) involving the use of a tetrahydrofuran (THF) gradient. The influence of THF as mobile phase in LC-MS coupling, which is not common practice, was evaluated. In Atmosperic Pressure Chemical Ionisation (APCI) in the negative ion mode, the presence of THF in the mobile phase did not degrade the MS signal of the target compounds in the conditions studied. On the contrary, an improvement was even observed when the percentage of THF increased. The proposed PGC-LC-MS method was selective and linear for the six phenolic compounds analysed with limits of quantification lower than 5 ppm in all cases. The precision was satisfactory (pooled RSD around 6%). The analyses of OMW matrix spiked sample confirmed the good performance of the proposed method.

Chromatography, Liquid↗

Degradation of imidacloprid in water by photo-Fenton and TiO2 photocatalysis at a solar pilot plant: a comparative study.

The technical feasibility, mechanisms, and performance of degradation of aqueous imidacloprid have been studied at pilot scale in two well-defined photocatalytic systems of special interest because natural UV light can be used: heterogeneous photocatalysis with titanium dioxide and homogeneous photocatalysis by photo-Fenton. Equivalent pilot-scale and field conditions used for both allowed adequate comparison of the degree of mineralization and toxicity achieved as well as the transformation products generated in route to mineralization by both systems. Ninety-five percent of mineralization (<2.0 mg/L) was reached after 250 min of photocatalytic treatment with Fenton and 450 min with TiO2, meaning that TOC disappears 2.4 times faster with photo-Fenton photocatalytic treatment than with TiO2. The Daphnia Magna test for final residual TOC does not reveal anytoxic behavior. Transformation products evaluated by GC-MS/AED after two SPE procedures and LC-IC were the same in both cases. The main differences between the two processes are in the amount of transformation products (TPs) generated, not in the TPs detected which were always the same. At the end of both processes low concentration (<0.1 mg/L) of 2 pyrrolidinone (transformation product) remains in the dissolution and around 1 mg/L of formate in the case of photo-Fenton.

Ferric Compounds↗

Gas chromatographic determination of pesticides in vegetable samples by sequential positive and negative chemical ionization and tandem mass spectrometric fragmentation using an ion trap analyser.

A selective and sensitive chromatographic method is described for the determination of nine organochlorine and organophosphorus pesticides in vegetable samples by gas chromatography-mass spectrometry. The proposed method combines the use of positive and negative chemical ionisation and tandem mass spectrometric fragmentation, resulting in a significant increase in selectivity and allowing the simultaneous confirmation and quantification of trace levels of pesticides in complex vegetable matrices. Parameters relative to ionisation and fragmentation processes were optimised to obtain maximum sensitivity. Repeatability and reproducibility studies yielded relative standard deviations lower than 25% in all cases. Identification criteria, such as retention time and relative abundance of characteristic product ions, were also evaluated in order to guarantee the correct identification of the target compounds. The method was applied to real vegetable samples to demonstrate its use in routine analysis.

Gas Chromatography-Mass Spectrometry↗

Multiresidue method for the analysis of five antifouling agents in marine and coastal waters by gas chromatography-mass spectrometry with large-volume injection.

A simple multiresidue method has been developed for the determination of five pesticides, commonly used as active ingredients in antifouling paints, in seawater samples. The pesticides studied were: chlorothalonil (2,4,5,6-tetrachloroisophthalonitrile), dichlofluanid (N-dimethyl-N-phenylsulphamide), Sea-Nine 211 (4,5-dichloro-2-n-octyl-4-isothazolin-3-one), Irgarol 1051 (2-methylthio-4-tert.-butylamino-6-cyclopropylamino-s-triazine) and TCMTB (2-thiocyanomethylthiobenzothiazole). The analytes were extracted from 200 ml water samples, using solid-phase extraction. A copolymer with hydrophilic-lipophilic balance was used as sorbent yielding good recoveries (82-95%) for most compounds except dichlofluanid and Sea-Nine 211 (<60%). Large volume injection (10 microl) gas chromatography and electron impact ionization MS (selected ion monitoring mode) detection enabled these compounds to be identified and quantified at the 1.2-3.0 ng/l level. Analysis of samples performed in three marinas in Almería (Spain) revealed the presence of Irgarol 1051 in all the cases, at concentration levels between 25 and 450 ng/l.

Aniline Compounds↗

Solar photocatalytic mineralization of commercial pesticides: acrinathrin.

A comparative study of the degradation of commercial acrinathrin spiked in water using TiO2 photocatalysis and photolysis under sunlight was performed. Samples were analysed by liquid chromatography-diode array detector (HPLC-DAD) and gas chromatography-ion trap-mass spectrometric detector (GC-ITMS). Additional total organic carbon (TOC) analyses were carried out to evaluate the mineralisation rates. One photoproduct, 2-phenoxy benzaldehyde, was unequivocally identified and evaluated by GC-ITMS during the processes. Although acrinathrin is almost destroyed when exposed to irradiation for more than 400 h, photocatalysis with TiO2 noticeably reduced degradation to a few hours. In this case, with the additional presence of peroxydisulphate, in less than 2 h acrinathrin is completely destroyed. Mineralisation of acrinathrin, without catalyst, was only around 50% after 400 h of irradiation.

Catalysis↗

Splitless large-volume GC-MS injection for the analysis of organophosphorus and organochlorine pesticides in vegetables using a miniaturised ethyl acetate extraction.

A simple, rapid and sensitive multiresidue method has been developed for the determination of ten organophosphorus and organochlorine pesticides, commonly used in crop protection. The analysis uses a miniaturised extraction with ethyl acetate followed by large volume injection (10 microL) GC-EI-MS analysis in SIM (selective ion monitoring) mode. Sensitivity and selectivity of the method were acceptable with limits of detection (LODs) lower than 0.01 mg kg-1, except for endosulfan alpha and beta (0.05 mg kg-1). Average recoveries of between 63-99% were obtained and good linearity was observed in the range from 0.01 to 1.00 mg kg-1. Repeatability and reproducibility studies yielded relative standard deviations lower than 20% in all the cases. The method was applied to the analysis of 110 tomato, pepper and cucumber samples, as part of the monitoring programme of the Association of Producers and Exporters of Fruits and Vegetables of Almería.

Acetates↗

Comparison of various sample handling and analytical procedures for the monitoring of pesticides and metabolites in ground waters.

Various sample handling techniques such as liquid-liquid extraction off-line and on-line, solid-phase extraction followed by either gas chromatography (GC) with electron-capture, flame photometric or mass spectrometric detection, or liquid chromatography (LC) with diode array detection were applied in the determination of a selected group of insecticides and fungicides in ground water samples at sub-micrograms/l levels. An evaluation of the advantages and drawbacks in the application of the proposed methodologies for water monitoring studies is discussed. For the selected group of pesticides studied, off-line C18 or polymeric cartridges followed by GC-MS using an ion trap analyzer have been revealed as the more powerful technique. But very polar compounds such as methamidophos or acephate have not been recovered with this procedure. On the contrary, on-line C18 LC-DAD offered a few drawbacks for the trace determination of a large group of pesticides as a consequence of many important interferences in the chromatographic traces. Other techniques evaluated were LC-MS and GC-MS using a quadrupole analyzer, which offered complementary information and were useful for a limited range of analytes. An interlaboratory study was performed using all the methodologies evaluated in this work and the results obtained showed a good agreement between all the applied techniques. The various methodologies were for a ground water pilot survey study in Almeria (Spain). Endosulfan was the most ubiquitous pesticide detected in this area.

Chromatography, Gas↗

Determination of imidacloprid in vegetables by high-performance liquid chromatography with diode-array detection.

An HPLC method is described for the determination of imidacloprid residues in vegetables at levels ranging from 0.01 to 0.60 mg/kg. The selection of the extraction and clean-up procedure is discussed. Spectral data obtained with diode-array detection allow the identification of imidacloprid residues. Thermospray mass spectrometric studies were carried out in combination with HPLC. The mean recoveries and standard deviations were 95% and 4.7%, respectively, in the various crops tested. Registration of the analytical results for a control sample in quality control charts demonstrated the performance of the method. Data for incurred residues of imidacloprid in vegetable samples routinely applying the proposed method are also presented.

Chromatography, High Pressure Liquid↗

Determination of imidacloprid and benzimidazole residues in fruits and vegetables by liquid chromatography-mass spectrometry after ethyl acetate multiresidue extraction.

A simple and sensitive method based on liquid chromatography-atmospheric pressure ionization-mass spectrometry is described for the determination of 4 benzimidazole pesticides (carbendazim, thiabendazole, benomyl, and thiophanate-methyl) and imidacloprid in vegetables and fruits. Food samples were typically extracted with ethyl acetate to draw the analytes into the organic phase. No cleanup step was necessary before injection into the liquid chromatographic (LC) system with electrospray mass spectrometric detection. The analytes were separated on a reversed-phase C8LC column. Limits of detection for the compounds were in the microg/L range. Results are reported for validation studies with fortified pear and tomato samples and for residues of the target compounds found in the pesticide residue monitoring program during 1998.

Acetates↗

Extraction of methamidophos residues from vegetables with supercritical fluid carbon dioxide.

A simple supercritical fluid extraction (SFE) method has been developed to efficiently extract incurred residues of methamidophos (a very polar pesticide) from fresh vegetable samples by using commercial SFE equipment and moderate SFE conditions. Vegetable samples were mixed with anhydrous magnesium sulfate and extracted with supercritical carbon dioxide at 300 atm and 50 degrees C with methanol as static modifier and a few milliliters of ethyl acetate as trapping system. Methamidophos recoveries were > 70% from 33 pepper, cucumber, and tomato samples at incurred levels ranging from 0.1 to 2.2 mg/kg. Triplicate analysis from 2 replicates at an incurred level of 0.53 mg/kg gave a coefficient of variation of 14%. Results for incurred residues of chlorpyrifos, endosulfan, and procymidone in some samples show that the SFE technique could be used as a multiresidue method.

Carbon Dioxide↗