PubMed Health⌕ Search

Biomedical subjects

A Amann

Publications and source records attributed to A Amann.

At least 19 recordsLinked to original sources

Synchronization in dynamical networks: evolution along commutative graphs.

Starting from an initial wiring of connections, we show that the synchronizability of a network can be significantly improved by evolving the graph along a time dependent connectivity matrix. We consider the case of connectivity matrices that commute at all times, and compare several approaches to engineer the corresponding commutative graphs. In particular, we show that synchronization in a dynamical network can be achieved even in the case in which each individual commutative graphs does not give rise to synchronized behavior.

Journal Article↗

Noise-induced front motion: signature of a global bifurcation.

We show that front motion can be induced by noise in a spatially extended excitable system with a global constraint. Our model system is a semiconductor superlattice exhibiting complex dynamics of electron accumulation and depletion fronts. The presence of noise induces a global change in the dynamics of the system forcing stationary fronts to move through the entire device. We demonstrate the effect of coherence resonance in our model; i.e., there is an optimal level of noise at which the regularity of front motion is enhanced. Physical insight is provided by relating the space-time dynamics of the fronts with a phase-space analysis.

Journal Article↗

[Women, age and mobility in traffic].

The observation that the topic "older women in traffic" does not hold a prominent position within existing literature in this field is the starting-point of this paper. Apart from a mere numerical deficiency of respective contributions, we assume in addition the existence of a conceptual weakness in the scientific discourse. Therefore we try to develop a general concept of mobility along age-relevant and gender-related dimensions, present afterwards-as an empirical supplement-some selected examples from focus group and in-depth interviews, and finally outline a proposition for a concept of mobility of older women (and men), which is intended to provide some practical reference for operationalization in empirical research. The frame of this concept is constituted by the assumption that outdoor mobility is rooted in social structures and their change, as they are represented in a certain historical time, and simultaneously, by purposeful action of the individuals involved, from which these structures finally emanate.

Accidents, Traffic↗

Synchronizing weighted complex networks.

Real networks often consist of local units, which interact with each other via asymmetric and heterogeneous connections. In this work, we explore the constructive role played by such a directed and weighted wiring for the synchronization of networks of coupled dynamical systems. The stability condition for the synchronous state is obtained from the spectrum of the respective coupling matrices. In particular, we consider a coupling scheme in which the relative importance of a link depends on the number of shortest paths through it. We illustrate our findings for networks with different topologies: scale free, small world, and random wirings.

Action Potentials↗

Synchronization is enhanced in weighted complex networks.

The propensity for synchronization of complex networks with directed and weighted links is considered. We show that a weighting procedure based upon the global structure of network pathways enhances complete synchronization of identical dynamical units in scale-free networks. Furthermore, we numerically show that very similar conditions hold also for phase synchronization of nonidentical chaotic oscillators.

Biophysics↗

Synchronization in complex networks with age ordering.

The propensity for synchronization is studied in a complex network of asymmetrically coupled units, where the asymmetry in a given link is determined by the relative age of the involved nodes. In growing scale-free networks, synchronization is enhanced when couplings from older to younger nodes are dominant. We describe the requirements for such an effect in a more general context and compare with the situations in nongrowing random networks with and without a degree ordering.

Computer Systems↗

[Transthoracic defibrillation. Physiologic and pathophysiologic principles and their role in the outcome of resuscitation].

As one major link in the chain of survival, early transthoracic (external) cardiac defibrillation is aimed at the termination of ventricular flutter and ventricular fibrillation. Most important to the success of defibrillation is the passage of a defined amount of current through a critical mass of heart muscle. Different transthoracic resistances reduce the effective density of the current within the heart. As for other therapeutic intervention procedures, recommendations for the optimal strength of current to be applied to the fibrillating heart need to be evaluated and defined for therapeutical defibrillation too. Unnecessarily high current density causes damage to the heart and should be prevented. By using biphasic waveforms in contrast to monophasic impulses, the amount of current can be reduced but the same or even higher efficacy is attained. Therefore possible myocardial damage might be clearly reduced. Even with individually altered thoracic impedance effective conversion of cardiac rhythm can be achieved by device-controlled compensation and biphasic waveforms. According to their different mechanisms or origin (electrically induced or spontaneously caused by organic heart disease) the probability of successful conversion of the cardiac rhythm by one single electrical impulse varies. The optimum point in time for defibrillation during resuscitation needs to be redefined. In order to improve comparability, further studies should use standardized definitions for successful defibrillation relating to the resulting cardiac rhythm.

Cardiopulmonary Resuscitation↗

Self-stabilization of high-frequency oscillations in semiconductor superlattices by time-delay autosynchronization.

We present a scheme to stabilize high-frequency domain oscillations in semiconductor superlattices by a time-delayed feedback loop. Applying concepts from chaos control theory we propose to control the spatiotemporal dynamics of fronts of accumulation and depletion layers which are generated at the emitter and may collide and annihilate during their transit, and thereby suppress chaos. The proposed method only requires the feedback of internal global electrical variables, viz., current and voltage, which makes the practical implementation very easy.

Journal Article↗

Time-delay autosynchronization of the spatiotemporal dynamics in resonant tunneling diodes.

The double barrier resonant tunneling diode exhibits complex spatiotemporal patterns including low-dimensional chaos when operated in an active external circuit. We demonstrate how autosynchronization by time-delayed feedback control can be used to select and stabilize specific current density patterns in a noninvasive way. We compare the efficiency of different control schemes involving feedback in either local spatial or global degrees of freedom. The numerically obtained Floquet exponents are explained by analytical results from linear stability analysis.

Journal Article↗

Hybrid model for chaotic front dynamics: from semiconductors to water tanks.

We present a general method for studying front propagation in nonlinear systems with a global constraint in the language of hybrid tank models. The method is illustrated in the case of semiconductor superlattices, where the dynamics of the electron accumulation and depletion fronts shows complex spatiotemporal patterns, including chaos. We show that this behavior may be elegantly explained by a tank model, for which analytical results on the emergence of chaos are available. In particular, for the case of three tanks the bifurcation scenario is characterized by a modified version of the one-dimensional iterated tent map.

Journal Article↗

[Analysis of ventricular fibrillation signals for the evaluation of defibrillation success in the treatment of ventricular fibrillation].

OBJECTIVE: Precise detection of ventricular fibrillation (VF), reliable prediction of defibrillation success and adjustment of the discharge waveform to the patient's transthoracic impedance may contribute to a reduction of electricity-associated myocardial injury caused by unnecessary counter shocks. Specifically, asystole thresholds distinguish between VF and asystole, and thus prevent unnecessary defibrillation attempts. We reviewed various studies and manufacturer characteristics regarding the parameters and algorithms for analyzing arrhythmia ECG signals. METHODS: Asystole threshold values of several defibrillator manufacturers were collected and a literature review was performed including the following parameters: amplitude, frequency, bispectral analysis, amplitude spectrum area, wavelets, nonlinear dynamics, N(alpha)histograms, and combinations of various parameters. RESULTS: The manufacturer dependent asystole thresholds vary substantially. We show ways to optimize an ECG-based analysis for the next technological generation of defibrillators. During advanced cardiac life support (ACLS) the probability of defibrillation success should be estimated. Optimal defibrillation waveform, depending on transthoracic resistance, should be individually determined. In case of prolonged VF with a low ECG amplitude defibrillation should not be attempted unless coronary perfusion has been improved by further measures of ACLS. The combined evaluation of VF amplitude and frequency is effective in predicting defibrillation success. Estimation of further parameters is potentially useful for guiding optimal timing of defibrillation. At present, the implementation of most parameters in out-of-hospital cardiopulmonary resuscitation (CPR) is limited by the lack of technical feasibility of online computing. CONCLUSION: Analysis of VF ECG signals should allow adequate VF detection as well as prediction of defibrillation success. Suitable asystole thresholds for analysis of ECG signals have to be determined, and the adverse effects of CPR associated artefacts on data analysis have to be reduced. Analysis of VF ECG signals is a precondition of individually optimized defibrillation and may contribute substantially to an increased quality of CPR.

Algorithms↗

Comparison of time-delayed feedback schemes for spatiotemporal control of chaos in a reaction-diffusion system with global coupling.

Time-delayed feedback control for stabilizing time periodic spatial patterns is investigated in a generic reaction-diffusion system with global coupling. We focus on the case of low-dimensional chaos where unstable patterns admit only a single unstable mode. Spatial degrees of freedom are taken into account to define different control schemes. The efficiency of these schemes is discussed, where control forces are motivated by physical requirements as well as by the possibility of obtaining analytically exact results. We find that control schemes that contain the full feedback of the inhibitor variable may finally destroy the control performance. Thus schemes that omit the inhibitor might be more efficient. Our numerical findings are explained in terms of Floquet spectra and compared with analytical solutions of particular coupling schemes.

Journal Article↗

Monitoring pollution by proton-transfer-reaction mass spectrometry during paediatric anaesthesia with positive pressure ventilation via the laryngeal mask airway or uncuffed tracheal tube.

Twenty children aged 2-66 months were randomly allocated for airway management with either the laryngeal mask airway or uncuffed tracheal tube using intermittent positive pressure ventilation with a tidal volume of 8 ml.kg-1 and a respiratory rate adjusted to maintain end-expiratory carbon dioxide concentration at 5.3 kPa. Induction was with fentanyl/propofol and maintenance was with sevoflurane 2.5% in oxygen/air. The airway device was removed when the patients were awake and the patients were transferred to the postanaesthesia care unit 10 min later. Air was sampled from a point 1.5 m above the floor at a location remote from the ventilation outlet and analysed using a proton-transfer-reaction mass spectrometer capable of continuous trace gas analysis at the parts per billion volume (ppbv) level. The concentration of sevoflurane was recorded every minute during three consecutive phases: for 5 min before the introduction of sevoflurane (background); after introduction of sevoflurane until removal of the airway device (intra-operative); and every minute after removal until the concentration returned to background levels. Median (interquartile range [range]) intra-operative sevoflurane concentrations were 200-400 times higher than background values for the laryngeal mask airway 1 (1-2 [0-3]) ppbv vs. 404 (278-523 [83-983]) ppbv, respectively, and the tracheal tube 2 (1-3 [0-5]) ppbv vs. 396 (204-589 [107-1735]) ppbv (both p < 0.0001), and returned to background values within 5 min of removal. There were no differences in sevoflurane concentration between devices intra-operatively or after removal. The performance of the proton-transfer-reaction mass spectrometer was identical at the start and end of the 30-day study. We conclude that peri-operative sevoflurane concentration in a modern operating theatre is similar for the laryngeal mask airway and the uncuffed tracheal tube in paediatric patients receiving intermittent positive pressure ventilation. Intra-operative sevoflurane concentrations are five times lower than occupational safety limit requirements, and 1000 times lower 5 min after removal of the airway device with the patient awake. The proton-transfer-reaction mass spectrometer has potential for monitoring air quality in the operating theatre.

Air Pollutants, Occupational↗

Neopterin as a marker of immunostimulation: an investigation in anaesthetic workplaces.

Personnel working in operating theatres and recovery rooms are exposed to a variety of noxious substances. The results of studies of the effects of occupational exposure on immune parameters are conflicting. Neopterin is an acknowledged marker of immunostimulation. Urinary neopterin levels of 58 anaesthetists and anaesthetic nurses were measured over a 3-week period. Neopterin analyses were performed using high performance liquid chromatography. Neopterin levels were within the normal range for all subjects. Younger subjects (aged < or = 35 years) had significantly higher urinary neopterin concentrations than older subjects (aged > 35 years). The present study is the first to investigate the influence of anaesthetic exposure on neopterin levels. No evidence of immunostimulation was found.

Adult↗

Dynamic scenarios of multistable switching in semiconductor superlattices.

We analyze the dynamics of charge distributions in weakly coupled, doped, dc voltage biased semiconductor superlattices subject to voltage steps of different sizes. Qualitatively different current responses to voltage switching processes have been observed experimentally. We explain them by invoking distinct scenarios for electric-field domain formation, validated by numerical simulations. Furthermore, we investigate the transient from an unstable to a stable point in the current-voltage characteristics after a steplike or ramplike increase of the external voltage.

Journal Article↗

Analysis of volatile organic compounds: possible applications in metabolic disorders and cancer screening.

The human breath contains a variety of endogenous volatile organic compounds (VOCs). The origin and pathophysiological importance of these VOCs is poorly investigated. Little is known about the interaction of VOCs from ambient air, such as those produced by plants and exhaust fumes, with the human organism. Gas chromatographic determination of VOC concentrations is tedious. Proton-transfer-mass spectroscopy (PTR-MS), a new technology for the online detection of VOC patterns, is a valuable alternative. We present two interesting molecular species, isoprene and ortho (o)-toluidine, as examples of endogenously produced VOCs. In a case study, breath isoprene reductions during lipid-lowering therapy (36%) were shown to correlate with cholesterol (32%) and LDL concentrations (35%) in blood (p < 0.001) over a period of 15 days. Therefore, isoprene concentrations in human breath (measured by PTR-MS) might serve as an additional parameter to complement invasive tests for controlling lipid-lowering therapy. Furthermore, it may be a useful parameter for lipid disorder screening. Mass-108, which presumably represents o-toluidine in our breath samples, was found in significantly higher concentrations in the breath of patients with different tumors (1.5 +/- 0.8 ppbv) than in age-matched controls (0.24 +/- 0.1 ppbv, p < 0.001). Inflammatory reactions do not seem to alter the pattern of mass-108. Therefore, it appears to be a currently underestimated carcinoma marker that deserves further investigation.

Adult↗

Functional tests for the characterization of surfactant protein B (SP-B) and a fluorescent SP-B analog.

Surfactant protein B (SP-B) enhances lipid insertion into the alveolar air/liquid interface upon inhalation. The aim of this study was (i) to apply a palette of tests for a detailed biochemical and biophysical characterization of SP-B and (ii) to use these tests to compare native SP-B with a fluorescent (Bodipy) SP-B analog. The method of labeling was fast and resulted in a covalent fluorophore-protein bond. The ability of both proteins to spread a surfactant film on top of a buffer surface was determined in a spreading tray using the Wilhelmy plate technique to allow detection of alterations in surface tension and calculation of spreading velocities. In a captive bubble surfactometer surface tensions of spread films were measured. Similar biophysical properties were found for both native and Bodipy-labeled SP-B. It is concluded that the combination of tests used allows detection of small differences in structure and activity between the two proteins.

1,2-Dipalmitoylphosphatidylcholine↗