PubMed Health⌕ Search

Biomedical subjects

A Anne

Publications and source records attributed to A Anne.

11 recordsLinked to original sources

Elastic bounded diffusion and electron propagation: dynamics of the wiring of a self-assembly of immunoglobulins bearing terminally attached ferrocene poly(ethylene glycol) chains according to a spatially controlled organization.

Molecular monolayers of immunoglobulins bearing terminally attached ferrocene poly(ethylene glycol) chains (IgG-PEG-Fc) were self-assembled at an electrode surface in a step-by-step manner involving antigen-antibody recognition reactions. The total number N of assembled IgG-PEG-Fc monolayers and the number of spacers n(i) separating two successive IgG-PEG-Fc monolayers were controlled and varied. Electron transport through the protein assembly involves the dynamics of the terminally attached PEG chains and isotopic electron exchange between ferrocene heads belonging to successive IgG-PEG-Fc monolayers. The model of elastic bounded diffusion enabled us to analyze quantitatively the dependence of the rate of electron transport on N, n(i), and the rate constant (k(e)) of isotopic electron exchange. Wiring of a molecular monolayer of redox enzyme is also quantitatively characterized.

Algorithms↗

Electrochemical approach to the dynamics of molecular recognition of redox enzyme sites by artificial cosubstrates in solution and in integrated systems.

Application of antigen-antibody technology allows the attachment to an electrode surface of an enzyme monolayer structure to which both the enzyme and the mediator are bound. As illustrated with the example of glucose oxidase and a ferrocene mediator, the enzyme preserves its full activity in such structures, which may be easily reproduced. In spite of their fixation to the structure, the mobility of the ferrocene heads is sufficient to ensure that its transport to the enzyme prosthetic group is not rate determining. The reaction is rather controlled by the prior formation of a complex between the ferrocenium ion and the flavin required for electron transfer to occur. The efficiency of this step is affected by steric hindrance and the various observations made with free-moving and attached ferrocene-ended poly(ethylene glycol) chains may be rationalized by the interplay of factors controlling their distribution and shape. Analyzing the dynamics of this system, in comparison with previous systems, was thus an occasion to shed further light on the recognition phenomenon. The enzyme monolayer integrated system is a good starting point for the step-by-step construction of spatially ordered multilayered assemblies with strong catalytic efficiencies. Fast responding systems are expected both in terms of electron transport and electron transfer between the mediator and the enzyme. The spatial order resulting from the step-by-step construction should allow a much more precise analysis of electron transport and electron transfer than in conventional assemblies of redox centers. Mastering both the construction and the functioning of such systems should help the design of more complex systems, integrating additional functionalities electrically controlled by means of their electron transport/electron transfer connection to the electrode surface.

Antigen-Antibody Complex↗

Can the combination of electrochemical regeneration of NAD+, selectivity of L-alpha-amino-acid dehydrogenase, and reductive amination of alpha-keto-acid be applied to the inversion of configuration of a L-alpha-amino-acid?

The inversion of configuration of L-alanine can be carried out by combining its selective oxidation in the presence of NAD+ and L-alanine dehydrogenase, electrochemical regeneration of the NAD+ at a carbon felt anode, and reductive amination of pyruvate, i.e., reduction of its imino derivative at a mercury cathode, the reaction mixture being buffered with concentrated ammonium/ammonia (1.28M / 1. 28M). The dehydrogenase exhibits astonishing activity and stability under such extreme conditions of pH and ionic strength. The main drawback of the process is its slowness. At best, the complete inversion of a 10 mM solution of L-alanine requires 140 h. A careful and detailed quantitative analysis of each of the key steps involved shows that the enzyme catalyzed oxidation is so thermodynamically uphill that it can be driven efficiently to completion only when both the coenzyme regeneration and the pyruvate reduction are very effective. The first condition is easily fulfilled. Under the best conditions, it is the rate of the chemical reaction producing the imine which controls the whole process kinetically. Copyright 1999 John Wiley & Sons, Inc.

Journal Article↗

Accuracy of the conductance catheter for measurement of ventricular volumes seen clinically: effects of electric field homogeneity and parallel conductance.

The conductance-volume method is an important clinical tool which allows the assessment of left ventricular function in vivo. However, the accuracy of this method is limited by the homogeneity of electric field the conductance catheter produces and the parallel conductance of surrounding structures. This paper examines these sources of error in volumes seen clinically. The characteristics of electric field within a chamber were examined using computer simulation. Nonconductive and conductive models were constructed and experimental measurements obtained using both single-field (SF) and dual-field (DF) excitation. Results from computer simulations and in vitro measurements were compared to validate the purposed theoretical model of conductance-volume method. The effects of field homogeneity and significance of parallel conductance in volume measurement were then determined. The results of this study show that DF provide a more accurate measure of intraventricular volume than SF, especially at larger volumes. However, both significantly underestimate true volume at larger volumes. In addition, the parallel conductance due to the chamber wall is significant at small volumes, but diminishes at larger volumes. Furthermore, the effect of parallel conductance beyond the chamber wall may be negligible. This study demonstrates the limitations in applying current conductance technology to patients with dilated hearts.

Animals↗

On evolutive systems and the initial evolution of structure and function.

As an instrument for the study of the early stages of evolution, we introduce evolutive systems, defined as systems that have the capacity to evolve given appropriate conditions in their environment. They consist of building blocks (e.g. monomers) that are either stable or in steady supply, and of transient assemblies (e.g. polymers) that are entities of great variety, some of which are capable of function. Evolution leads to the accumulation of structure within the transient assemblies during repeated cycles of disintegration (partial or total) and reassembly, on account of the selective advantages associated with transient assembly functions. Transient assemblies must be either inherently unstable or subject to disintegration by agents in their environment. Evolutive systems must have access to a negentropy input in the form of energy in packets larger than typical thermal energies. Reproduction, although not a prerequisite, greatly affects the capacity of evolutive systems to evolve, and thus can be expected to appear in an evolutive system if at all possible. Similarly, functions that require the expenditure of negentropy (for example mobility, breathing, circulation, sensing, communicating, etc.) are not prerequisites for evolution, but can be expected to become established in evolutive systems during evolution through the selective advantages that they confer. A computer-based evolutive automaton is used to explore possible evolutionary scenarios. In the presence of spatial and temporal inhomogeneities, one can construct a multitude of evolutionary scenarios through which various functions, such as the operation of genetic code, can become established within the evolutive automaton. This variety of possible evolutionary scenarios is all the more remarkable because the automaton does not include many important physical processes that would be present in a real system and would greatly multiply the number of possible evolutionary mechanisms and scenarios. Some evolutionary mechanisms are based on survival related selection, while others are based on generation related selection. Previously explored scenarios for the initiation of life have been based mostly on generation related selection. In this paper, we give particular emphasis to survival related selection which is more general in that it does apply to structures and functions related to reproduction but, unlike generation related selection, it is not limited to them. Some of the most basic features of terrestrial living systems can be seen either as prerequisite features of an evolutive system (such as the mortality of living organisms, instability of biological polymers, imperfect reproduction caused by mutations, and the need for a negentropy input) or as features that one can reasonably expect to become established in an evolutive system (such as reproduction and the multitude of living functions that require expenditure of negentropy). This suggests the possibility that an independent definition of living systems may not be necessary if features of living systems substantially overlap with features that one may expect to find in evolutive systems.

Animals↗

Evaluation of digital image enhancement techniques for liver scintigrams.

Digital image enhancement techniques were employed in an effort to improve the resolution of Anger camera liver images. The premise employed was that methods which improve lesion detectability in liver phantoms should also do so in actual liver scintigrams. The types of image processing evaluated were: contrast enhancement, finite and infinite impulse response, modulation transfer function correction, homomorphic and median filtering. Observers were used to evaluate each method for its ability to improve lesion detectability using a five category rating system. The Localization Receiver Operating Characteristic (LROC) curve was used as the primary rank ordering method. A point system and analysis of variance were used as corroborative methods, incorporating measures of accuracy and consistency of the observers' answers.

Humans↗

Epidemiology of serious burn injuries.

The incidence of serious burn injuries has been determined for the Commonwealth of Virginia during a 21 month period. The data set included all patients with burn injuries who entered the hospital and were considered to be in serious enough condition to require treatment in a hospital. The risk for burn injury was calculated by age, race and sex. Examination of the date revealed large differences in the magnitude of age-specific incidence rates between men and women and the white and nonwhite population. Differences in the economic status of the population may explain a large proportion of the variation in the crude burn rates.

Adolescent↗

Effect of maximal versus submaximal expiratory effort on spirometric values.

Data from flow volume curves suggest that flow measured at the mouth may be lower with maximal effort than with submaximal effort. We consequently studied the effect of maximal vs. submaximal expiratory effort on spirometric values. Significant increases in FVC, FEV1 or FEF25-75% with submaximal effort occurred in 12 of 38 subjects. All subjects who improved spirometric values had peak flows with submaximal efforts that varied from 91 to 65% of peak flow with maximal efforts. We conclude that spirometric values in some subjects are larger with submaximal rather than maximal effort.

Adult↗

Synthesis of the first ferrocene-labeled dideoxynucleotide and its use for 3'-redox end-labeling of 5'-modified single-stranded oligonucleotides.

The target ferrocene-labeled dideoxynucleotide compound 5-[N-(beta-ferrocenyl-propanoyl)3-amino-propyn-1-yl]-2',3'-dideoxyuridine 5'-triphosphate, Fc-ddUTP, was synthesized and tested with terminal deoxynucleotidyl transferase for enzymatic 3'-redox-active end-labeling of 5'-phosphorylated single-stranded oligodeoxynucleotides. Starting from readily available 5-iodouridine and 3-ferrocenylpropanoic acid, the synthetic strategy elaborated here follows a mild multistep route. Each step involves reliable methods, and all ferrocene intermediates can be easily purified. Enzymatic 3'-ferrocene end-labeling of 5'-phosphorylated oligonucleotides is remarkably efficient, and 3'-ferrocene-labeled oligonucleotides can thus be prepared in sufficient amounts for further use in surface modifications.

Animals↗