PubMed Health⌕ Search

Biomedical subjects

A Annerberg

Publications and source records attributed to A Annerberg.

5 recordsLinked to original sources

A new approach to evaluate regression models during validation of bioanalytical assays.

The quality of bioanalytical data is highly dependent on using an appropriate regression model for calibration curves. Non-weighted linear regression has traditionally been used but is not necessarily the optimal model. Bioanalytical assays generally benefit from using either data transformation and/or weighting since variance normally increases with concentration. A data set with calibrators ranging from 9 to 10000 ng/mL was used to compare a new approach with the traditional approach for selecting an optimal regression model. The new approach used a combination of relative residuals at each calibration level together with precision and accuracy of independent quality control samples over 4 days to select and justify the best regression model. The results showed that log-log transformation without weighting was the simplest model to fit the calibration data and ensure good predictability for this data set.

Algorithms↗

Development and validation of an automated solid phase extraction and liquid chromatographic method for the determination of piperaquine in urine.

A sensitive and specific bioanalytical method for determination of piperaquine in urine by automated solid-phase extraction (SPE) and liquid chromatography (LC) has been developed and validated. Buffered urine samples (containing internal standard) were loaded onto mixed phase (cation-exchange and octylsilica) SPE columns using an ASPEC XL SPE robot. Chromatographic separation was achieved on a Chromolith Performance RP-18e (100 mm x 4.6 mm I.D.) LC column with phosphate buffer (pH 2.5; 0.1 mol/L)-acetonitrile (92:8, v/v). Piperaquine was analysed at a flow rate of 3 mL/min with UV detection at 347 nm. A linear regression model on log-log transformed data was used for quantification. Within-day precision for piperaquine was 1.3% at 5000 ng/mL and 6.6% at 50 ng/mL. Between-day precision for piperaquine was 3.7% at 5000 ng/mL and 7.2% at 50 ng/mL. Total-assay precision for piperaquine over 4 days using five replicates each day (n = 20) was 4.0%, 5.2% and 9.8% at 5000, 500 and 50 ng/mL, respectively. The lower limit of quantification (LLOQ) was set to 3 ng/mL using 1 mL of urine, which could be lowered to 0.33 ng/mL when using 9 mL of urine and an increased injection volume.

Animals↗

High throughput assay for the determination of lumefantrine in plasma.

A high throughput bioanalytical assay for the determination of lumefantrine in plasma has been developed and validated extensively. The within-day precisions for lumefantrine were 5.2, 3.5 and 2.5% at 200, 2000 and 15000 ng/mL, respectively. The between-day precisions were 4.0, 2.8 and 3.1% at 200, 2000 and 15000 ng/mL, respectively. The lower limits of quantification (LLOQ) and the limits of detection (LOD) were 25 and 10 ng/mL, respectively using 0.250 mL plasma. The average recovery of lumefantrine was 85% and independent upon concentration. The use of 96-well plate format and short chromatographic run has increased the daily sample throughput four times. The assay is particularly suitable for large therapeutic drug monitoring studies using day 7 sampling.

Antimalarials↗

Development and validation of a bioanalytical method using automated solid-phase extraction and LC-UV for the simultaneous determination of lumefantrine and its desbutyl metabolite in plasma.

A bioanalytical method for the determination of lumefantrine (LF) and its metabolite desbutyl-lumefantrine (DLF) in plasma by solid-phase extraction (SPE) and liquid chromatography has been developed. Plasma proteins were precipitated with acetonitrile:acetic acid (99:1, v/v) containing a DLF analogue internal standard before being loaded onto a octylsilica (3 M Empore) SPE column. Two different DLF analogues were evaluated as internal standards. The compounds were analysed by liquid chromatography UV detection on a SB-CN (250 mm x 4.6 mm) column with a mobile phase containing acetonitrile-sodium phosphate buffer pH (2.0; 0.1 M) (55:45, v/v) and sodium perchlorate 0.05 M. Different SPE columns were evaluated during method development to optimise reproducibility and recovery for LF, DLF and the two different DLF analogues. The within-day precisions for LF were 6.6 and 2.1% at 0.042 and 8.02 microg/mL, respectively, and for DLF 4.5 and 1.5% at 0.039 and 0.777 microg/mL, respectively. The between-day precisions for LF were 12.0 and 2.9% at 0.042 and 8.02 microg/mL, respectively, while for DLF 0.7 and 1.2% at 0.039 and 0.777 microg/mL, respectively. The limit of quantification was 0.024 and 0.021 microg/mL for LF and DLF, respectively. Different amounts of lipids in plasma did not affect the absolute recovery of LF or DLF.

Chromatography, Liquid↗

Development and validation of a solid-phase extraction-liquid chromatographic method for determination of amoxicillin in plasma.

A bioanalytic method for the determination of amoxicillin in plasma by hydrophilic interaction solid-phase extraction and liquid chromatography has been developed and validated. Plasma was precipitated with acetonitrile before samples were loaded onto a zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) solid-phase extraction column. Amoxicillin was analyzed by liquid chromatography on an Aquasil (150 x 4.6 mm) LC column with mobile-phase acetonitrile: phosphate buffer (pH 2.5; 0.1 mol/L) (7:93, v/v) and UV detection at 230 nm. A regression model using 1/concentration weighting was found the most appropriate for quantification. The intraassay precision for plasma was 3.3% at 15.0 microg/mL and 10.9% at 0.200 microg/mL. The interassay precision for plasma was 1.8% at 15.0 microg/mL and 7.5% at 0.200 microg/mL. The total-assay precision for plasma over 4 days using a total of 20 replicates was 13.2%, 5.5%, and 3.8% at 0.200 microg/mL, 3.00 microg/mL, and 15.0 microg/mL, respectively. The lower limit of quantification and the limit of detection were 0.050 microg/mL and 0.025 microg/mL, respectively, for 100 microL plasma. Long-term storage stability studies of amoxicillin in plasma indicate that a temperature of -80 degrees C is necessary to prevent degradation of amoxicillin.

Amoxicillin↗