PubMed Health⌕ Search

Biomedical subjects

A B Ellis

Publications and source records attributed to A B Ellis.

5 recordsLinked to original sources

Guest editorial.

Explore the source record for details and available documents.

Journal Article↗

Mediation of retinal photoisomerization by adduct formation with tris(6,6,7,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedionato)-europium(II).

Several retinal isomers are shown to form adducts in isooctane solution with a lanthanide beta-diketonate complex, tris(6,6,7,8,8,8-heptafluoro-2,2-dimethyl-3,5-octanedionato)europium(III) [Eu(fod)3]. The adducts are characterized by an absorption band whose lambda max at approximately 420 nm is red-shifted by approximately 60 nm from the lowest-energy absorption band in the free retinal isomers. Irradiation into this adduct band leads to photoisomerization. For example, photolysis of a 1 mM all-trans-retinal/3 mM Eu(fod)3 isooctane solution at 514.5 nm leads, with reasonable quantum efficiency (phi greater than or equal to 0.05), to isomeric mixtures that are considerably different from these produced with UV excitation in the absence of Eu(fod)3. Particularly noteworthy for a photolysis conducted in a nonpolar solvent is the presence of an appreciable quantity of 11-cis-retinal in the adduct photolysate.

Europium↗

Comparison of the strength and holding power of 4 pin designs for use with half pin (type I) external skeletal fixation.

The strength and holding power of four pin designs for use with half pin (type I) external skeletal fixation were evaluated. Pins that were tested were fully threaded, nonthreaded, two cortices partially threaded, and one cortex partially threaded. The study involved three parts: (1) resistance of the pins to axial extraction immediately after insertion; (2) resistance of the pins to axial extraction 8 weeks after being inserted into the tibiae of live dogs; and (3) resistance of the pins to bending load. Pins with threads engaging two cortices were more resistant to axial extraction than nonthreaded pins in both the acute (p less than 0.0001) and chronic (p less than 0.0001) studies. Nonthreaded pins were more resistant to bending than fully threaded and two cortices partially threaded pins (p less than 0.0005). One cortex partially threaded pins possessed similar bending strength to nonthreaded pins (p = 0.21) and had 5.3 times more resistance to axial extraction in the acute study (p less than 0.0001) and 6.9 times more in the chronic study (p less than 0.0001). Though one cortex partially threaded pins were not as resistant to axial extraction as pins with threads engaging two cortices (p less than 0.0001), they were more resistant to bending loads (p less than 0.0005). Loss of holding power and pin failure are two of the most serious problems associated with fracture stabilization using external skeletal fixation. The results of this study suggest that one cortex partially threaded pins are better at maintaining holding power and resisting bending and breaking than nonthreaded pins.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗