PubMed Health⌕ Search

Biomedical subjects

A Barty

Publications and source records attributed to A Barty.

5 recordsLinked to original sources

Damped and thermal motion of laser-aligned hydrated macromolecule beams for diffraction.

We consider a monodispersed Rayleigh droplet beam of water droplets doped with proteins. An intense infrared laser is used to align these droplets. The arrangement has been proposed for electron- and x-ray-diffraction studies of proteins which are difficult to crystallize. This paper considers the effect of thermal fluctuations on the angular spread of alignment in thermal equilibrium, and relaxation phenomena, particularly the damping of oscillations excited as the molecules enter the field. The possibility of adiabatic alignment is also considered. We find that damping times in a high-pressure gas cell as used in x-ray-diffraction experiments are short compared with the time taken for molecules to traverse the beam and that a suitably shaped field might be used for electron-diffraction experiments in vacuum to provide adiabatic alignment, thus obviating the need for a damping gas cell.

Chemistry, Physical↗

Quantitative phase-amplitude microscopy. III. The effects of noise.

We explore the effect of noise on images obtained using quantitative phase-amplitude microscopy - a new microscopy technique based on the determination of phase from the intensity evolution of propagating radiation. We compare the predictions with experimental results and also propose an approach that allows good-quality quantitative phase retrieval to be obtained even for very noisy data.

Artifacts↗

Quantitative phase-amplitude microscopy I: optical microscopy.

In this paper, the application of a new optical microscopy method (quantitative phase-amplitude microscopy) to biological imaging is explored, and the issue of resolution and image quality is examined. The paper begins by presenting a theoretical analysis of the method using the optical transfer function formalism of Streibl (1985). The effect of coherence on the formation of the phase image is explored, and it is shown that the resolution of the method is not compromised over that of a conventional bright-field image. It is shown that the signal-to-noise ratio of the phase recovery, however, does depend on the degree of coherence in the illumination. Streibl (1985) notes that partially coherent image formation is a non-linear process because of the intermingling of amplitude and phase information. The work presented here shows that the quantitative phase-amplitude microscopy method acts to linearize the image formation process, and that the phase and amplitude information is properly described using a transfer function analysis. The theoretical conclusions are tested experimentally using an optical microscope and the theoretical deductions are confirmed. Samples for microscopy influence both the phase and amplitude of the light wave and it is demonstrated that the new phase recovery method can separate the amplitude and phase information, something not possible using traditional phase microscopy. In the case of a coherent wave, knowledge of the phase and amplitude constitutes complete information that can be used to emulate other forms of microscopy. This capacity is demonstrated by recovering the phase of a sample and using the data to emulate a differential interference contrast image.

Journal Article↗

Quantitative phase-sensitive imaging in a transmission electron microscope

This paper presents a new technique for forming quantitative phase and amplitude electron images applicable to a conventional transmission electron microscope. With magnetised cobalt microstructures used as a test object, we use electron holography to obtain an independent measurement of the phase shift. After a suitable calibration of the microscope, we obtain quantitative agreement of the phase shift imposed on the 200 keV electrons passing through the sample.

Journal Article↗

Noninterferometric quantitative phase imaging with soft x rays.

We demonstrate quantitative noninterferometric x-ray phase-amplitude measurement. We present results from two experimental geometries. The first geometry uses x rays diverging from a point source to produce high-resolution holograms of submicrometer-sized objects. The measured phase of the projected image agrees with the geometrically determined phase to within +/-7%. The second geometry uses a direct imaging microscope setup that allows the formation of a magnified image with a zone-plate lens. Here a direct measure of the object phase is made and agrees with that of the magnified object to better than +/-10%. In both cases the accuracy of the phase is limited by the pixel resolution.

Journal Article↗