PubMed Health⌕ Search

Biomedical subjects

A Baumbach

Publications and source records attributed to A Baumbach.

At least 19 recordsLinked to original sources

Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.

AIMS: A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS: A total of 102 patients underwent both conventional and MDCT coronary angiography. After intravenous injection of a non-ionic contrast medium the entire heart was scanned within a single breath hold using 1mm slices. All MDCT data sets were reconstructed with retrospective gating at 20% to 80% in increments of 10% relative to the cardiac cycle. Two blinded independent reviewers analysed image quality for segments 1-4 (right coronary artery), 5-8 (left main, left anterior descending), and 11, 12 (left circumflex). These segments were evaluated for the presence or absence of significant (>or=50%) stenoses. The results were compared with those of invasive coronary angiography in a blinded fashion. Overall sensitivity for the detection of significant stenoses (>or=50%) were 0.86 (reader 1) and 0.93 (reader 2), specificity 0.96 (reader 1) and 0.97 (reader 2), negative predictive value 0.98 (reader 1) and 0.99 (reader 2). CONCLUSIONS: High resolution MDCT angiography with retrospective gating permits the non-invasive detection of coronary artery stenoses with high accuracy if image quality is optimized for each of the three major coronary arteries.

Coronary Angiography↗

Virtual coronary angioscopy using multislice computed tomography.

BACKGROUND: With faster image acquisition times and thinner slice widths, multislice detector computed tomography (MSCT) allows visualisation of human coronary arteries with diagnostic image quality. In addition to conventional axial slices, virtual coronary angioscopies (VCA) can be reconstructed using MSCT datasets. OBJECTIVE: To evaluate the feasibility of reconstructing VCA and to determine the clinical value of this new application in detecting atherosclerotic coronary artery lesions. METHODS: Datasets obtained by contrast enhanced non-invasive coronary angiography using MSCT (Somatom VZ) were analysed from 14 consecutive patients. VCA were simulated in 14 coronary arteries (left anterior descending, n = 7; right coronary, n = 7). Lesion detection was undertaken on conventional contrast enhanced axial slices, as well as by VCA. Intracoronary ultrasound (ICUS) was used as the gold standard for in vivo plaque detection. RESULTS: 38 lesions were detected both on ICUS and on axial slices: 14 severe target lesions of > 75% area stenosis (11 calcified, three non-calcified), and 24 intermediate lesions of < or = 75% area stenosis (seven calcified, 17 non-calcified). Using VCA, all severe lesions (n = 14) and all calcified intermediate plaques (n = 7) could clearly be identified. However, non-calcified intermediate lesions (n = 17) could not be accurately distinguished from the vessel wall; they were recognised as vessel wall alterations without significant luminal narrowing. CONCLUSIONS: Current MSCT technology allows reconstruction of VCA with good image quality. Despite a more anatomical view of heart and coronary vessels on three dimensional reconstruction, conventional axial slices were found to be superior for detecting coronary lesions. Thus further technical innovations are required before VCA can become a useful technique in clinical cardiology.

Adult↗

Population need for coronary revascularisation: are national targets for England credible?

OBJECTIVE: To estimate the need for coronary revascularisation, by using an incidence of indications approach, among 45-84 year olds with stable angina, unstable angina, and acute myocardial infarction. DESIGN: Modelling exercise. Six key steps along the pathway of care from initial diagnosis in primary or secondary care to revascularisation were defined and the frequency of indications estimated using routine data from hospital admissions and data from studies in the general population, and primary and secondary care. SETTING AND PATIENTS: Mid-1998 population of England. INTERVENTION: Coronary revascularisation. MAIN OUTCOME MEASURE: Ability to benefit (need), defined by randomised trials, expert panel ratings from the ACRE (appropriateness of coronary revascularisation) study, or by informal consensus. RESULTS: The need for coronary revascularisation was estimated to be 92 000 procedures, equivalent to a rate of 1861 per million population. Overall, the model of need exceeded current provision by 3.3:1, although among people aged 75 years and over the ratio was 7.7:1. A plausible upper estimate of need--obtained by assuming that 90% of patients with stable angina were referred from primary care and that angiography would be performed in 65% of patients with acute myocardial infarction and 75% of patients with unstable angina--was 2626 per million population. CONCLUSIONS: The national target of 1500 revascularisation procedures per million population is credibly related to population need, although upper estimates of need are considerably higher. Better understanding is required of the benefits of referring patients with specific indications from primary care. The greatest relative increase in provision is required for those aged 75 and older, among whom trial evidence of benefit is scant.

Aged↗

Prophylaxis of restenosis with (186)re-labeled stents in a rabbit model.

BACKGROUND: Intraluminal beta-irradiation has been shown to decrease neointimal proliferation after angioplasty in experimental models. The purpose of this study was to test the technical feasibility and biological effects of (186)Re-labeled stents. METHODS AND RESULTS: Thirty-four New Zealand White rabbits were fed a 0.5% cholesterol diet before balloon angioplasty and insertion of Palmaz stents in the infrarenal aorta. The animals were killed 7 weeks after stent implantation. Two of 34 animals died prematurely (aortic leak, pneumonia). Control stents (n=7) were compared with (186)Re stents (2.6 MBq [n=6], 8.1 MBq [n=5], 16.0 MBq [n=6], and 25.3 MBq [n=8]). Stent application was successful in all cases. No thrombus occlusion was observed. After 7 weeks, neointima formation was 2.2+/-0.2 mm(2) in the control group. In the treatment groups, a dose-dependent neointima reduction was detectable (0.5+/-0.5 mm(2) [2.6 MBq], 0.4+/-0.4 mm(2) [8.1 MBq], and 0 mm(2) [16.0 MBq, 25.3 MBq]). No induction of neointimal formation was observed at the edges of the stents. Radiation resulted in delayed reendothelialization. CONCLUSIONS: (186)Re stents were capable of reducing neointima formation in a dose-dependent fashion. (186)Re stents did not cause late thrombosis or neointimal induction at the stent margins in the observation period of 7 weeks.

Animals↗

Noninvasive detection of coronary lesions by multislice computed tomography: results of the New Age pilot trial.

The reliable noninvasive assessment of coronary artery disease would constitute an important step forward in clinical cardiology. The aim of the New Age pilot trial was to evaluate the diagnostic accuracy of multislice computed tomography (MSCT) in determining coronary lesions. As a gold standard for in vivo plaque detection, intracoronary ultrasound (ICUS) was used. Forty plaques were detected by ICUS in 15 target vessels (LAD, n = 8; RCA, n = 7) in patients assigned for ICUS-guided PTCA. Preinterventional MSCT was performed in all patients and the results were compared to ICUS with regard to lesion detection and quantification. According to ICUS results, the 40 plaques were divided into three groups: group I, mild lesions < 50% (n = 14; 44.36% +/- 5.77%); group II, intermediate lesions 50%-75% (n = 12; 59.18% +/- 9.39%); and group III, severe lesions > 75% (n = 14; 91.47% +/- 3.68%). All MSCT scans showed sufficient image quality for analysis. Thirty of 40 (75%) plaques were detected by MSCT in a first blinded session. After unblinding the ICUS results, the remaining 10 (25%) plaques could be identified. Lesion severity was classified correctly in 34 of 40 (85%) plaques. Plaque calcifications were diagnosed correctly in 16 of 19 (84.2%) plaques. Quantification of vessel size revealed a good correlation to the ICUS results (r(2) 0.68; P = 0.004). Noninvasive MSCT angiography showed good diagnostic accuracy with regard to lesion detection and quantification of vessel size. The overall good image quality, makes this new technology a promising modality, which might become an alternative diagnostic approach in patients with known or suspected coronary artery disease. Cathet Cardiovasc Intervent 2001;53:352-358.

Adult↗

Local delivery of paclitaxel using the double-balloon perfusion catheter before stenting in the porcine coronary artery.

Paclitaxel is a new cancer chemotherapeutic agent that has been approved for clinical use in patients with a variety of different cancers. Paclitaxel inhibits cell proliferation by an action on microtubules. The aim of this study was to evaluate the safety and efficacy of locally delivered paclitaxel after coronary stent implantation. A novel double-balloon perfusion catheter was used to deliver the drug locally in the pig coronary artery. Twenty-seven domestic pigs underwent stent implantation of the left anterior descending artery. In the treatment group (n = 11), paclitaxel (10 ml; 10 micromol/l) was delivered using the double-balloon perfusion catheter prior to stent implantation. The control group received stent implantation only (n = 16). The animals were sacrificed 4 weeks later. Vessels were perfusion-fixed and morphometric analysis was performed using conventional techniques. In addition, the extent of injury was determined at each stent-strut area. Correlation of local injury and neointimal thickness was evaluated by linear regression. Neointimal thickness (paclitaxel 1.0 +/- 0.4 vs. control 0.7 +/- 0.3 mm), neointimal area (paclitaxel 4.1 +/- 2.2 vs. control 2.4 +/- 1.1 mm(2)), and the lumen area (paclitaxel 2.1 +/- 1.9 vs. control 2.5 +/- 0.9 mm(2)) did not show significant differences between both groups. Medial area (3.3 +/- 2.3 vs. 1.6 +/- 0.4 mm(2)) was larger in the vessels treated with paclitaxel (P < 0.05). Linear regression failed to show any difference in the response to injury between the two groups. Local delivery of paclitaxel with the double-balloon-perfusion catheter did not reduce neointima formation following stent implantation in native pig coronary arteries.

Angioplasty, Balloon↗

Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound.

The reliable non-invasive detection of coronary artery disease (CAD) is a prime goal for future developments in clinical cardiology. In addition to the documentation of high-grade stenoses, the detection of vulnerable plaques is of major importance for risk stratification and early treatment to prevent plaque rupture. Recently, a new generation of fast spiral CT has been introduced using a multi-slice technique (MSCT), which is the first real quantum leap in CT since the introduction of spiral CT in the early 1990s. We report on non-invasive differentiation of coronary plaque morphology by MSCT in patients with lesions in the proximal left anterior descending artery (LAD). The results were compared with the findings of intracoronary ultrasound (ICUS). The ICUS and MSCT scans were analysed in 6 patients scheduled for ICUS-guided PTCA. One target lesion was selected in each patient. On ICUS, two lesions were classified as soft, two as intermediate and two as calcified according to established criteria based on echogenicity. By multislice CT, density measurements (expressed in Hounsfield Units, HU) were performed at 16 randomly selected areas within the plaques. The two soft plaques showed a mean density of 6+/-28 and -5+/-25 HU, the two intermediate plaques of 83+/-17 and 51+/-19 HU, and the two calcified plaques of 489+/-372 and 423+/-111 HU. To our knowledge, this is the first report on non-invasive characterisation of coronary lesions by MSCT. Plaque composition could be clearly differentiated and classified according to the ICUS results by determining tissue density within the lesions. Thus, this new technology holds promise for non-invasive risk assessment in patients with known or suspected CAD since also rupture-prone soft coronary lesions can be detected by use of this new technique.

Aged↗

Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography.

OBJECTIVES: The aim of the present study was to evaluate the accuracy in determining coronary lesion configuration by multislice computed tomography (MSCT). The results were compared with the findings of intracoronary ultrasound (ICUS). BACKGROUND: The risk of acute coronary syndromes caused by plaque disruption and thrombosis depends on plaque composition rather than stenosis severity. Thus, the reliable noninvasive assessment of plaque configuration would constitute an important step forward for risk stratification in patients with known or suspected coronary artery disease. Just recently, MSCT scanners became available for general purpose scanning. Due to improved spatial and temporal resolution, this new technology holds promise to allow for differentiation of coronary lesion configuration. METHODS: The ICUS and MSCT scans (Somatom Volume Zoom, Siemens, Forchheim, Germany) were performed in 15 patients. Plaque composition was analyzed according to ICUS (plaque echogenity: soft, intermediate, calcified) and MSCT criteria (plaque density expressed by Hounsfield units [HU]). RESULTS: Thirty-four plaques were analyzed. With ICUS, the plaques were classified as soft (n = 12), intermediate (n = 5) and calcified (n = 17). Using MSCT, soft plaques had a density of 14 +/- 26 HU (range -42 to +47 HU), intermediate plaques of 91 +/- 21 HU (61 to 112 HU) and calcified plaques of 419 +/- 194 HU (126 to 736 HU). Nonparametric Kruskal-Wallis test revealed a significant difference of plaque density among the three groups (p < 0.0001). CONCLUSIONS: Our results indicate that coronary lesion configuration might be correctly differentiated by MSCT. Since also rupture-prone soft plaques can be detected by MSCT, this noninvasive method might become an important diagnostic tool for risk stratification in the near future.

Adult↗

Self-rated health and clinical status after PTCA: results of a 4-year follow-up in 500 patients.

Background: Data on the clinical long-term outcome of patients with coronary artery disease in the years following percutaneous interventions are rare. We therefore decided to conduct a study to: (1) analyze the efficiency of a retrospective inquiry using a questionnaire and (2) perform a clinical long-term follow-up of our patients. Methods and results: Some 45+/-7 months after PTCA, a questionnaire was sent to 549 patients who had been treated at our institution from July 1, 1989, to June 30, 1991. The response rate was 91.1%, with 49 patients (8.9%) lost to follow-up. A total of 115/500 patients (23%) had reinterventions due to severe angina (69 patients (13.8%) undergoing re-PTCA and 46 (9.2%) CABG). Sixteen patients (3.2%) had a myocardial infarction and 35 patients (7.0%) died. Multivariate analysis revealed that patients who were asymptomatic 3 months after PTCA were likely to have a good long-term outcome. This was not found when comparing the clinical status immediately after PTCA to follow-up. Medical therapy with beta-blockers/aspirin/lipid-lowering drugs decreased from 75.2/82.2/35.4% at hospital discharge to 54.6/76.7/25.2% at follow-up. Conclusions: The present study provided important quality data for our institution. The response rate to the questionnaire was surprisingly high (91.1%), indicating that retrospective inquiries may also be efficient. The rate of reinterventions during long-term follow-up (23%) was acceptably low. Good self-rated health 3 months after the intervention turned out to be a strong predictor for a good clinical long-term outcome. Furthermore, we observed an underuse of cardiac medication, something that will be the subject of further quality improvement measures.

Journal Article↗

Accuracy and reliability of quantitative measurements in coronary arteries by multi-slice computed tomography: experimental and initial clinical results.

AIM: To evaluate the accuracy of non-invasive measurements within coronary arteries by multi-slice computed tomography (MSCT). We present experimental as well as clinical data. MATERIALS AND METHODS: Silicon tubes simulating coronary arteries (outer diameter 6 mm, lumen diameter within stenotic area 2 mm) were used for experimental studies. Clinical data were derived from 15 patients in whom vessel diameters were assessed by MSCT, intracoronary ultrasound (ICUS) and quantitative coronary angiography (QCA). MSCT were performed in a Somatom Volume Zoom(trade mark)CT system (Siemens, Forchheim, Germany) at 2 collimated slice widths (2.5 mm, 1.0 mm). RESULTS: Outer silicon tube diameters were overestimated by MSCT (6.56 mm +/- 0.32 mm). All measurements revealed significantly better results on 1.0 collimation compared to 2.5 mm collimation (outer diameter: 6.36 mm +/- 0.22 mm vs 6.76 mm +/- 0.27 mm, P < 0.0001; lumen diameters: 1.83 mm +/- 0.14 mm vs 1.51 mm +/- 0.19 mm, P < 0.0001). The comparison of vessel diameters within human coronary arteries revealed comparable results between ICUS and MSCT (4.89 mm +/- 0.67 mm vs 4.91 mm +/- 0.71 mm, P = 0.79, r = 0.79, P < 0.0001). QCA-measurements showed significantly lower results (3.67 +/- 0.71, P < 0.0001, r = 0.62, P < 0.001). CONCLUSIONS: Experimental as well as initial clinical results indicate acceptable reliability and accuracy of quantitative measurements by MSCT, when using thin collimated slice widths. Partial volume effects lead to a systematic overestimation of vessel size. MSCT has the potential to become an important non-invasive diagnostic tool in patients with coronary artery disease.

Coronary Angiography↗

Local intra-arterial drug delivery for prevention of restenosis: comparison of the efficiency of delivery of different radiopharmaceuticals through a porous catheter.

RATIONALE AND OBJECTIVES: Several radiopharmaceuticals were administered through a porous balloon catheter to compare the absolute amount deposited and the retention in the vessel wall. The reported efficiency of local drug delivery ranges from 0.001% to 0.1%, with poor retention after 24 hours. METHODS: An endothelin derivative (n = 6), pertechnetate (n = 6), hexamethylpropylene amineoxime (HMPAO) (n = 5), ethyl cysteinate dimer (ECD) (n = 5), and tin colloid (n = 5) were labeled with 185 MBq/mL 99m-technetium. After balloon denudation of the infrarenal aorta in 27 New Zealand White rabbits, 100 microL of each agent was administered through a porous balloon at a pressure of 4 bar. Dynamic and static whole-body scintigrams were obtained for 24 hours. The infrarenal aorta was excised and the activity calculated in a gamma counter. RESULTS: Apart from their retention in the region of local administration, the radiopharmaceuticals showed different distribution patterns. The highest regional tracer retention was observed with HMPAO. After administration of HMPAO, a significant difference between regional (vessel wall plus surrounding tissue: 14.5% of injected dose [ID]/24 hours) and local (vessel wall: 1.8% ID/24 hours) delivery was found. In contrast, ECD was eliminated quickly (local retention after 24 hours = 0% ID). The retention efficiencies were HMPAO > endothelin derivative > tin colloid > pertechnetate > ECD. CONCLUSIONS: The different physicochemical and pharmacokinetic properties of radiopharmaceuticals resulted in different delivery efficiencies after local application.

Animals↗

A new device for percutaneous suture-mediated closure of arterial puncture sites using exteriorized needles: initial experience.

PURPOSE: To assess the feasibility and initial clinical results of Closer (Perclose, Redwood City, California), a new device for percutaneous suture-mediated closure of arterial puncture sites. METHODS: Vascular interventions were performed using 6 and 7 French sheaths in 22 consecutive patients. All patients underwent suture-mediated percutaneous closure with the new device. Patients were followed by physical examination the day after the procedure. RESULTS: Immediate hemostasis was achieved in 20/22 patients (91%). In 3 out of 5 antegrade closures, only one suture was captured. In two cases, this was managed by reinsertion of a second device. In another patient, hemostasis was not achieved by the device due to knot entrapment. No major complications were observed. The overall rate of minor complications was 9% (2/22) due to hematomas without the need for blood transfusions. CONCLUSION: Percutaneous suture with this new device is an acceptably safe and effective method to achieve immediate hemostasis of the arterial access site after interventional procedures with minimized manipulation of the puncture track.

Adult↗

Fibrin specificity and procoagulant effect related to the kallikrein-contact phase system and to plasmin generation with double-bolus reteplase and front-loaded alteplase thrombolysis in acute myocardial infarction.

This study was undertaken to compare the effects of reteplase and alteplase regimens on hemostasis and fibrinolysis in acute myocardial infarction (AMI). Thrombolytic treatment in patients with AMI is hampered by paradoxical procoagulant effects that favor early reocclusion. In vivo data comparing this effect and the fibrin specificity of double-bolus reteplase and front-loaded alteplase regimens are not available. In a prospective, randomized study, 50 patients with AMI were either treated with double bolus (10 + 10 U) reteplase or with front-loaded alteplase (up to 100 mg) within 6 hours of symptom onset. Thirty apparently healthy persons served as controls. Molecular markers of coagulation and fibrinolysis were serially examined for up to 5 days. Paradoxical thrombin activation at 3 hours after initiation of therapy was comparable between reteplase and alteplase. Reteplase (65 +/- 5 U/L) and alteplase (72 +/- 8 U/L) caused significantly elevated kallikrein activity at 3 hours after adminstration (p <0.01 vs controls 30 +/- 1 U/L). Fibrin specificity was less for reteplase (p <0.05) with a decrease in fibrinogen at 3 hours to 122 +/- 27 mg/dl versus 224 +/- 28 mg/dl for alteplase (p <0.01 and p <0.05 vs controls). D-Dimer levels at 3 hours were higher (p <0.05) after reteplase (5,459 +/- 611 ng/ml) versus alteplase (3,445 +/- 679 ng/ml) (both p <0.01 vs controls 243 +/- 17 ng/ml). Plasmin generation (plasmin-antiplasmin complexes) was significantly (p <0.01) increased at 3 hours with both regimens to 27,079 +/- 3,964 microg/L (reteplase) and 19,522 +/- 2,381 microg/L (alteplase). The data from 3 hours after start of thrombolytic therapy proved less marked fibrin specificity of the reteplase regimen (in vivo) compared with front-loaded alteplase. Both regimens have a moderate procoagulant effect without differences in activation of the kallikrein system.

Adult↗

[Results of a survey of 549 patients regarding long-term clinical outcome and quality of life four years after PTCA].

BACKGROUND: Quality control becomes increasingly important in interventional cardiology. Since in most health care systems, clinical treatment of patients who underwent percutaneous transluminal coronary angioplasty (PTCA) is left to general practitioners, important information on the clinical long-term outcome is lost for the cardiologic centers. Aim of this study was to evaluate the clinical status of these patients 4 years after treatment with a PTCA at our institution. PATIENTS AND METHODS: Inclusion criterion was the treatment with a PTCA within July 1, 1989 to June 30, 1991 (549 patients). A questionnaire was sent to all patients (45 +/- 7 months after PTCA). Four time-points were defined: before PTCA (T1), directly after PTCA (T2), 3 months after PTCA (T3) and actual status (T4). RESULTS: Questionnaires of 500/549 (91.1%) patients could be analyzed. One-hundred and fifteen patients (23%) had to undergo reinterventions: 69 (13.8%) had a re-PTCA and 46 (9.2%) patients an operative revascularization. At T4, 11.2% patients still had disturbing angina. Within the study period 35 patients (7%) died. Two-hundred and nineteen patients attended a rehabilitation institution. At T4, the amount of patients with little angina was not different comparing patients with/without the attendance of a rehabilitation institution (60.7% vs 66.4% p = 0.29). The rate of new pensioners after PTCA (n = 114 [22.8%]) was higher in the group of patients who attended a rehabilitation (68 patients [13.6%] with vs 48 patients [9.2%] without attendance, p = 0.0036). The attendance of a rehabilitation institution, however, had positive effects on changes of the life style and eating habits. CONCLUSIONS: This retrospective inquiry was found to be a useful tool (response rate 91.1%) for quality control in interventional cardiology. Important information concerning the quality of the interventions (low reintervention rate) and the long-term outcome of our patients (low rate with severe angina at T4) could be acquired.

Aged↗

[Paclitaxel: a chemotherapeutic agent for prevention of restenosis? Experimental studies in vitro and in vivo].

Paclitaxel, a potent anti-tumor agent, shifts the cytoskeleton equilibrium towards assembly of altered and extraordinarily stable microtubules. These cellular modifications lead to reduced proliferation, migration, and signal transduction. It is highly lipophilic, which promotes a rapid cellular uptake, and has a long-lasting effect in the cell due to the structural alteration of the cytoskeleton. This makes paclitaxel a promising candidate for local drug delivery intended to address the proliferative and migratory processes involved in restenosis. In this article, results of our in vitro and in vivo studies with paclitaxel are presented. Cell culture experiments with monocultures of human arterial smooth muscle cells as well as co-cultures with human endothelial cells showed that paclitaxel leads to an almost complete growth inhibition within a dose range of 1.0-10.0 mumol/l, even after a short (20 min) single dose application. The comparison of an active, semi-active, and passive delivery system (porous balloon, microporous balloon, and double balloon) favored the double balloon for the following in vivo experiments. Tubulin staining and electron microscopy enabled visualization of paclitaxel-induced vessel wall alterations. In the rabbit model, locally delivered paclitaxel resulted in reduced neointima formation and enlargement in vessel size; in the pig model, however, after stenting, this inhibition was not significant. Both reduced proliferation and enlargement in vessel size contribute to a preservation of vessel shape and are likely to be caused by a structural alteration of the cytoskeleton, which is also supported by vascular contraction force experiments.

Angiogenesis Inhibitors↗

[Use of Abciximab in threatening vascular occlusion after PTCA].

UNLABELLED: The administration of GP IIb/IIIa antagonists has been shown to be effective in reducing myocardial infarction and cardial death when given before PTCA. This prospective study was performed to determine the efficacy of abciximab in a bail-out situation to manage threatened or acute vessel closure. METHODS: Acute or threatened vessel closure was observed in 104 (5.5%) out of 1903 consecutive patients treated with PTCA in our institution. Of the 104 patients 46 (44%) were treated for unstable angina (CCS IV). Abciximab was administered in bail-out situations in a dosage of 0.25 mg/kg given as a bolus, which was followed by an intravenous infusion of 10 micrograms/min over 12 hours. Repeat PTCA was performed shortly after the administration of the abciximab bolus. After the procedure, the sheath was left in place and control angiography was carried out 24 h later. RESULTS: In 100 of the 104 patients TIMI flow III could be restored by abciximab therapy and RePTCA. In 4 patients an additional stent implantation was necessary due to persistent flow limitation. One day post PTCA, early follow-up angiography demonstrated patency of all vessels except two. In-hospital events occurred in 4 patients. Three of these patients underwent emergency CABG due to subacute vessel closure a few hours after PTCA and died during or directly after surgery. Follow-up after one year included clinical status and control angiography of the target vessel. During long-term follow-up, MACE occurred in 15 patients (2 MI, 8 CABG and 5 RePTCA). CONCLUSION: The results of this prospective trial demonstrate the efficacy of abciximab therapy in bail-out situations occurring during or early after PTCA. The use of abciximab in bail-out situations appears clinically beneficial. Further studies have to compare the efficacy of this approach with prophylactic abciximab treatment.

Abciximab↗