Development of a creatinine ELISA and an amperometric antibody-based creatine sensor with a detection limit in the nanomolar range.

Creatinine-specific antibodies have been generated and used for highly sensitive and specific immunochemical creatinine determinations. Creatinine was derivatized at N3 and coupled to KLH carrier protein. On the basis of this immunogen, monoclonal antibodies were developed by hybridoma technology. Antibodies from various clones have been characterized with BIAcore 2000 with respect to the dissociation constant and specificity. Antibodies of clone B90-AH5 exhibited the lowest dissociation constant (0.74 microM) and the highest specificity for creatinine and were chosen for the development of a competitive ELISA and an amperometric creatinine sensor. The creatinine sensor was constructed by fixing a creatinine-modified membrane on the top of a platinum working electrode which was then incorporated into a stirred electrochemical measuring cell. For creatinine determination the creatinine-containing sample was incubated with B90-AH5 and anti-IgG(mouse)-glucose oxidase conjugate and applied to the measuring cell. After a washing step glucose was added and the produced hydrogen peroxide was registered at Eappl = +600 mV vs Ag/AgCl. The measuring range was 0.01-10 microg/mL. The highest sensitivity for creatinine was achieved at 330 ng/mL (3 microM) and the lower detection limit at 4.5 ng/mL (40 nM). This is far below the relevant clinical range, which is 5-17 microg/mL (44-150 microM) and allows a reliable determination of very low creatinine concentrations in serum, where standard methods cannot be applied. After each measurement the sensor was regenerated with 10 mM HCl without any loss in binding activity.

Antibodies, Monoclonal↗

Enzyme kinetic assays with surface plasmon resonance (BIAcore) based on competition between enzyme and creatinine antibody.

A procedure is described which allows the characterization of enzyme by a hybrid approach using an enzyme and an antibody. The presented method is related to the affinity determination of antibodies by the 'affinity in solution' procedure for BlAcore. The antibody is used as an indicator for the concentration of substrate, which is also the antigen. A mixture of enzyme, substrate and antibody is incubated, and an aliquot of this solution is injected periodically into a flowcell containing immobilized substrate, which is bound by the antibody, but not cleaved by the enzyme. The chosen initial concentration of substrate inhibits the binding of antibody to the immobilized substrate by 90%. During the enzymatic reaction, increased amounts of antibody bind to the surface, as the substrate concentration is decreased. With this method, the cleavage of creatinine with creatinine iminohydrolase (6 mU/ml) was monitored for up to 11 h. A recently developed monoclonal antibody against creatinine was used as the indicating protein. For the calculation of enzyme activity, the signals were compared with a calibration curve for inhibition of antibody binding to the chip by creatinine in solution.

Aminohydrolases↗

Electrochemical immunoassays.

Immunoassays (IA) use the specific antigen antibody complexation for analytical purposes. Radioimmunoassays (RIA), fluorescence immunoassays (FIA) and enzyme immunoassays (EIA) are well established in clinical diagnostics. For the development of hand-held devices which can be used for point of care measurements, electrochemical immunoassays are promising alternatives to existing immunochemical tests. Moreover, for opaque or optically dense matrices electrochemical methods are superior. Potentiometric, capacitive and amperometric transducers have been applied for direct and indirect electrochemical immunoassays. However, due to their fast detection, broad linear range and low detection limit, amperometric transducers are preferred. Competitive and noncompetitive amperometric immunoassays have been developed with redox compounds or enzymes as labels. This review will give an overview of the most frequently applied principles in electrochemical immunoassays. The potential of an indirect competitive amperometric immunoassay for the determination of creatinine within nanomolar range and the circumvention of the most serious problem in electrochemical immunoassays, namely regeneration, will be discussed.

Animals↗