PubMed Health⌕ Search

Biomedical subjects

A Berthemy

Publications and source records attributed to A Berthemy.

2 recordsLinked to original sources

Quantitative determination of an extremely polar compound allantoin in human urine by LC-MS/MS based on the separation on a polymeric amino column.

Quantitative determination of allantoin in biological matrix poses a challenge to bioanalysis due to the extreme polarity of allantoin. The molecule exhibits virtually no retention on any of the available hydrophobic HPLC packing materials. In this study, an assay was developed for the LC-MS/MS quantitation of allantoin in human urine using a polymeric amino column to achieve the necessary separation. The urine samples were prepared by a single-step solid phase extraction (SPE) procedure. The extracted samples were analyzed on a jordi-gel DVB polyamine column (operated under an acetonitrile/water gradient with water as the stronger mobile phase) interfaced with a Finnigan TSQ 7,000 mass spectrometer. Negative electrospray ionization (ESI) was employed as the ionization source. Allantoin and its internal standard (13C1, 15N1-allantoin) were detected by use of single reaction monitoring (SRM) mode. The method was validated in the concentration range of 14.6-213 microg/ml(-1), with within and between run accuracy and precision both < 7%. The method has been successfully applied to clinical sample analysis.

Acetonitriles↗

High throughput liquid chromatography/mass spectrometry bioanalysis using 96-well disk solid phase extraction plate for the sample preparation.

The 96 well solid phase extraction (SPE) operated by robot in the LC/MS/MS bioanalysis offered rapid sample preparation for drugs and metabolites in biological matrices, based on simultaneous extraction of 96 samples. The use of a disk as sorbent in the 96 well plate further improved the performance of SPE and allowed for small elution volumes, making it possible to 'dilute and shoot" after SPE elution. In this study, a 96 well plate (Empore) was developed, characterized and optimized for several pharmaceutical compounds. In addition, a robot (MultiProbe) was modified to automate the 96 well plate operation. Examples were given to illustrate the major differences of using 96 well disk plate SPE in the method development as compared to the traditional SPE. This technology has been successfully used to support many clinical studies. Typically, a batch of 96 samples were prepared in 1-1.5 hours unattended (except for the replacement of a collection plate). Considerable savings in disposable supplies were also noted.

Anti-Asthmatic Agents↗