PubMed Health⌕ Search

Biomedical subjects

A Bertsch

Publications and source records attributed to A Bertsch.

8 recordsLinked to original sources

The sensing contact lens.

A novel contact lens with embedded sensors is being developed for continuous monitoring of the intraocular pressure in glaucoma patients. Its mode of operation and capabilities are described.

Biosensing Techniques↗

A biotechnological process for treatment and recycling poultry feathers as a feed ingredient.

A strain of Kocuria rosea with keratinolytic capacity was cultured aerobically on submerged feathers to obtain a fermented feather meal (FFM). This FFM enriched with cells of K. rosea mainly contains crude protein (71%). The pepsin digestibility of the fermented product (88%) was similar to the value of the commercial feather meal and more than 70% greater that untreated feathers. The bacterial biomass improved the content of amino acids lysine (3.46%), histidine (0.94%) and methionine (0.69%). Additionally, the amino acid availability tested by in vivo assay was greater than commercial feather meal. The microbial cells also supplied carotenoid pigments to FFM (68 ppm). These results suggest that feather meal enriched with K. rosea may be useful in animal feeding as protein and pigment source.

Amino Acids↗

Determination of carbonyl compounds in pool water with O-(2,3,4,5,6-pentafluorobenzyl)hydroxyamine hydrochloride and gas chromatographic-tandem mass spectrometric analysis.

To avoid microbiological decay pool water is disinfected, a procedure which results into a lot of disinfection by-products, like carbonyl compounds, as well as a large number of others. The carbonyl compounds dissolved in pool water were derivatisized with O-(2,3,4,5,6-pentafluorobenzyl)hydroxyamine hydrochloride (PFBHA) and extracted using n-hexane. Measuring with the help of GC-electron-capture detection is hardly possible because of interferents like halogenated organics. Another method to detect the PFBHA derivates is the use of tandem mass spectrometry. Calibration ranges and precision are applicable and sufficient to determine carbonyl compounds in pool water.

Gas Chromatography-Mass Spectrometry↗

Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity.

The study of intracellular communication requires devices that can not only monitor the bioelectric activity, but also control and observe the biochemical environment at the cellular level. This paper reports on the development and characterisation of implantable polyimide microprobes that allow simultaneous, selective chemical delivery/probing and multi-channel recording/stimulation of bioelectric activity. The key component of the system is a flexible polyimide substrate with embedded microchannels that is batch-fabricated combining polyimide micromachining and a lamination technique. The devices provide platinum microelectrodes on both sides of the polyimide substrate with an active surface between 20 microm x 20 microm and 50 microm x 50 microm. The embedded microchannels permit highly localised drug delivery or probing at the tip of the device via channel outlets adjacent to the microelectrodes. The microelectrodes were characterised by electrical impedance spectroscopy and the microchannels were studied in microflow experiments. Two different fluid delivery schemes were explored in two different designs. The first device type consists of a simple combination of microchannels and microelectrodes on one substrate. Liquids are ejected at the tip of the device by pressure injection techniques. The second device was inspired by the so-called U-tube concept allowing for highly localised delivery of controlled amounts of liquids in the picoliters range. Thus, the influence of chemical compounds on the electrical activity of cells can be studied with high temporal and spatial resolution. The flexible, implantable devices can be used for studying the chemical and electrical information exchange and communication of cells in in vivo and in vitro experiments.

Biosensing Techniques↗

Polyimide and SU-8 microfluidic devices manufactured by heat-depolymerizable sacrificial material technique.

The following paper describes a sacrificial layer method for the manufacturing of microfluidic devices in polyimide and SU-8. The technique uses heat-depolymerizable polycarbonates embedded in polyimide or SU-8 for the generation of microchannels and sealed cavities. The volatile decomposition products originating from thermolysis of the sacrificial material escape out of the embedding material by diffusion through the cover layer. The fabrication process was studied experimentally and theoretically with a focus on the decomposition of the sacrificial materials and their diffusion through the polyimide or SU-8 cover layer. It is demonstrated that the sacrificial material removal process is independent of the actual channel geometry and advances linearly with time unlike conventional sacrificial layer techniques. The fabrication method provides a versatile and fast technique for the manufacturing of microfluidic devices for applications in the field of microTAS and Lab-on-a-Chip.

Coated Materials, Biocompatible↗

Static micromixers based on large-scale industrial mixer geometry.

Mixing liquids at the micro-scale is difficult because the low Reynolds numbers in microchannels and in microreactors prohibit the use of conventional mixing techniques based on mechanical actuators and induce turbulence. Static mixers can be used to solve this mixing problem. This paper presents micromixers with geometries very close to conventional large-scale static mixers used in the chemical and food-processing industry. Two kinds of geometries have been studied. The first type is composed of a series of stationary rigid elements that form intersecting channels to split, rearrange and combine component streams. The second type is composed of a series of short helix elements arranged in pairs, each pair comprised of a right-handed and left-handed element arranged alternately in a pipe. Micromixers of both types have been designed by CAD and manufactured with the integral microstereolithography process, a new microfabrication technique that allows the manufacturing of complex three-dimensional objects in polymers. The realized mixers have been tested experimentally. Numerical simulations of these micromixers using the computational fluid dynamics (CFD) program FLUENT are used to evaluate the mixing efficiency. With a low pressure drop and good mixing efficiency these truly three-dimensional micromixers can be used for mixing of reactants or liquids containing cells in many microTAS applications.

Journal Article↗

Evidence for a NO synthase in porcine platelets which is stimulated during activation/aggregation.

We tried to characterize the porcine platelet nitric oxide (NO) synthase and its L-arginine (L-arg)/NO metabolism. Using RT-PCR we could show a constitutive endothelial NOS (ecNOS) and an inducible NOS (iNOS) similar mRNA in platelets. The NOS protein could be evidenced by an ecNOS specific antibody which also bound in platelets. This finding could be confirmed by Western blot showing an ecNOS in the membrane but not the cytosolic fraction; iNOS protein could not be detected. Using NADPH-diaphorase staining we could show NO synthase in preactivated platelets but not in resting platelets, indicating that the platelet NOS may be activated during platelet activation/aggregation. Porcine L-arg plasma levels (9.31 x 10(-5) mol/l +/- 10%) could be shown to be in the same range as human plasma levels. Moreover, we could show that the NO precursor L-arg and hydroxy-L-arginine (OHarg) concentration dependently inhibited collagen induced platelet aggregation. Summarizing these results confirm the existence of and further characterize porcine platelet NO synthases.

Animals↗