[Physical mechanisms of solid-protein interactions in the interface between amorphous silicon carbide and fibrinogen].

State of the art in biomaterial research and implant design is a compromise between functionality and biocompatibility. Consequently the results often have disadvantages with respect to both aspects. In regard to biocompatibility the activation of the clotting system by alloplastic materials is of great significance, because it necessitates anticoagulant therapy. Further improvements of implant technology require an understanding of the interactions between blood and implants. Therefore a microscopic model of thrombogenesis at alloplastic surfaces will shortly be presented, which relates thrombogenicity of a material to the electronic structure of its surface. The requirements for high hemocompatibility, which result from this model--especially in regard to the density of states and the conductivity at the surface--are fulfilled by an amorphous alloy of silicon and carbon (a-SiC:H). The advantage of amorphous materials is that they do not obey stoichiometric rules. Thus they allow a continuous adjustment of the electronic parameters without fundamental changes of their mechanical and chemical properties. The theoretical results where checked by total internal reflection intrinsic fluorescence spectroscopy (TIRIF) as well as thrombelastography experiments (TEG). In comparison to conventional materials like titanium or LTI carbon the TEG-clotting time of a-SiC:H-coatings is prolonged in excess of 200%. As a consequence a-SiC:H is well suited as a hemocompatible coating material for hybrid structuring of cardiovascular implants.

Biocompatible Materials

Artificial heart valves: improved blood compatibility by PECVD a-SiC:H coating.

Implants are steadily increasing in importance as substitutions for body functions. With the present state of the art, the limitations of the application of cardiovascular implants are due to insufficient performance of biomaterials. Present research in this field is being concentrated on efforts to improve the thrombus resistance of conventional materials by coating with semiconducting materials to actively influence the electrochemical interaction between the condensed matter and blood proteins. Based on an electrochemical model of the interaction of fibrinogen with an artificial surface and the resulting requirements for improving hemocompatibility, a coating of amorphous hydrogenated silicon carbide deposited by plasma-enhanced chemical vapor deposition (PECVD) is presently under evaluation as a special coating material for cardiovascular prostheses and is herein described. In particular, first results are published concerning the optimum deposition parameters in the PECVD process and cell culture tests. Experimental results of comparative partial thromboplastin time studies serve the purpose of proving the validity of the electrochemical reaction model referring the hemocompatibility of implantable materials to their semiconducting surface properties. The aim of this article is to demonstrate a feasible method for an antithrombogenic surface modification based on doped amorphous silicon carbide films that is in full conformance to the above mentioned model.

Biocompatible Materials

[Mechanical aspects of the development of artificial heart valves].

The development of an antithrombogenic coating permits a hybrid design for artificial heart valves. A substrate material optimized for its application is coated to meet the electrochemical requirements of improved hemocompatibility. But future progress in artificial heart valves requires an improvement in design as well as of the material. The basis of both aspects is the determination of such fundamental mechanical properties as the elasticity and plasticity of the valve ring and the deformation and fraction behaviour of the occluder. Analytical and numerical calculations of various different models result in different requirements for the substrate of ring and occluder. A combination of high elastic temper and low resistance to flow requires a ring material with a Young's modulus of 40 GPa or more, and a 0.2% proof stress to (Young's modulus)2/3 ratio of 0.3 MPa1/3. The best occluder materials should have a Young's modulus of more than 50 GPa and a flexural strength of at least 800 MPa. On the basis of these criteria, a heart valve consisting of a TiA15Fe2,5 ring and occluders made partially stabilized zirconia is introduced.