PubMed Health⌕ Search

Biomedical subjects

A Bonafé

Publications and source records attributed to A Bonafé.

At least 19 recordsLinked to original sources

In vitro evaluation of 2D-digital subtraction angiography versus 3D-time-of-flight in assessment of intracranial cerebral aneurysm filling after endovascular therapy.

BACKGROUND AND PURPOSE: The aim of this study was to evaluate 2D-digital subtraction angiographic (DSA) and 3D-time-of-flight (TOF) MR imaging in assessment of aneurysmal residue by using a pulsating silicon aneurysm model. For each imaging system, we studied intra- and interobserver reproducibility and the agreement between interpretations and reference measurements. We also examined how each imaging technique affected the operator's therapeutic decision. METHODS: Two silicon aneurysm models depicting subarachnoidal aneurysms were used, one with a wide neck and one with a narrow neck. Each aneurysm model was placed in series on a pulsed flow circuit and was filled with Guglielmi detachable coils to simulate a clinical case. Each aneurysm was then gradually filled with silicon gel in increments of 10%, up to 100% to simulate different levels of occlusion (residual neck or dog ear, partial, complete) at each filling level. For each level of filling, we performed conventional 2D-DSA and 3D-TOF MR imaging. We submitted the images for examination by 2 senior medical staff with 2 readings per image. A combined reading of the 2 images was submitted to each expert to determine whether the 2 examinations were complementary. RESULTS: The 2D-DSA analysis showed good reproducibility (k = 0.8 and k = 0.57) and agreement (k = 0.71) in describing "complete" treatments. The distinction between a "residual neck" and "partial treatment," however, was not reliable. The 2D-DSA provided a good description of the coil and silicon protrusion into the parent artery. The 3D-TOF analysis of the residual aneurysm, however, was not reproducible, though it was more effective than the 2D-DSA in evaluation of partially wide-necked aneurysms (k = 0.68 MR imaging vs k = 0.041 2D-DSA; P = .018). At the same filling level, the 2D-DSA analysis indicated repeat treatment more often than 3D-TOF analysis (P = .059). CONCLUSION: The 2D-DSA remains the gold standard, but MR imaging is more effective in evaluating a "partial treatment." The 2D-DSA analysis indicated repeat treatment more often than the 3D-TOF for the same occlusion level. The distinction between "partial treatment" and a "residual neck" was not reliable with either method of evaluation.

Angiography, Digital Subtraction↗

Multicenter evaluation of a self-expanding carotid stent system with distal protection in the treatment of carotid stenosis.

PURPOSE: Carotid artery stent placement may be limited by the embolization of atheromatous material. We evaluated the safety and feasibility of the Medtronic Self-Expanding Carotid Stent (Exponent) in combination with the Medtronic Interceptor Carotid Filter System for the treatment of carotid stenosis among patients at high risk for carotid endarterectomy. METHODS: Patients at high risk for carotid endarterectomy but amenable to percutaneous treatment with stent placement were enrolled. Clinical follow-up was performed at 30 days and 6 and 12 months postprocedure. The National Institutes of Health Stroke Scale was assessed before and within 3 days postprocedure and at 30 days and 6 months postprocedure. Angiography was performed pre- and postprocedure, and carotid duplex scans were performed at baseline and at 30 days and 6 months. RESULTS: Fifty-two carotid procedures were performed in 51 patients (mean age, 69 years; 84% of patients were men). The major adverse event (MAE) rate (death, stroke, and myocardial infarction [MI]) at 30 days was 5.9%: 2 strokes and a single death from periprocedural MI. MAE rates after 6 and 12 months were 5.9% and 11.8%, respectively. The delivery success rate was 94.2% (49/52) for the Interceptor Filter System and 95.9% (47/49) for the Exponent Stent. The mean diameter stenosis of the target lesion was reduced from 62.4% preprocedure to 21.2% postprocedure. CONCLUSION: High delivery success rates were achieved with a low rate of MAE (death, stroke, or MI) in a high-risk population. Treatment of carotid artery disease with the Exponent Carotid Stent combined with distal protection from the Interceptor Filter System is effective and safe.

Aged↗

Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry.

BACKGROUND AND PURPOSE: Endovascular treatment of intracranial aneurysms by using detachable coils has become an accepted alternative to surgery. To reduce the rate of aneurysm recanalization after treatment, biologically active polyglycolic/polylactic acid-covered platinum coils have been proposed. A prospective and multicenter registry was conducted in France to evaluate the safety and short-term and long-term efficacy of Matrix detachable coils. This first analysis is focused on the safety and short-term efficacy. METHODS: Two hundred sixty-one patients having ruptured or unruptured aneurysms treated via endovascular approach were included in this registry. Patients with giant aneurysms or in poor clinical condition (Glasgow Coma Scale < 10) were excluded. Because of various protocol violations, clinical analysis was conducted in 236 patients having 244 aneurysms. Technical and clinical complications were systematically recorded. Angiographic analysis was performed by a core laboratory by using the Raymond Grading Scale on 224 patients having 232 aneurysms. RESULTS: Complete occlusion was achieved in 102 aneurysms (44.0%); neck remnant, in 58 aneurysms (25.0%); and aneurysm remnant, in 72 aneurysms (31.0%). Technical and clinical complications related to the procedure were encountered in 43 patients (18.2%). Postoperative modification of the clinical status was observed in 12 patients (5.1%). Two patients died (0.8%), 6 had a permanent deficit (2.5%), and 4 had a transient deficit (1.7%). Treatment-related mortality was 0.8% and permanent morbidity was 2.5%. CONCLUSION: Endovascular treatment of intracranial aneurysms by using Matrix detachable coils is feasible and demonstrated initial angiographic results and overall morbidity and mortality rates that are within the ranges found in the literature in the use of bare platinum coils.

Adolescent↗

[Acutely ruptured intracranial aneurysms treated with GDC coils. Results from a single center over a period of 5 years].

PURPOSE: We prospectively reviewed the clinical results of acutely ruptured cerebral aneurysms treated with GDC over a 5 year period, in order to characterize death and dependency factors. METHODS: Between 1997 and 2002, 229 patients (254 aneurysms treated, 140 females, 89 males; mean age: 51 years) with aneurysmal subarachnoid hemorrhage were treated with GDC (Boston Scientific Neurovascular, Fremont, CA) once the anatomical conditions of feasibility had been achieved. Over 90% of the aneurysms treated (mean size: 5,8 mm) were located in the anterior circulation. The anterior communicating artery complex (87 cases), the posterior aspect of the internal carotid artery (65 cases), and the middle cerebral artery (49 cases) were most commonly treated. RESULTS: At the end of the initial hospitalization period, 14 patients (6.1%) died. Major procedural complications were associated with perforation of the aneurysmal sac in 9 patients (3.9%), thromboembolic events in 10 patients (4.3%) which resulted in 2 deaths (0.8%) and permanent neurologic morbidity in 7 patients (3%). The univariate analysis demonstrated no correlation between death and time-to-treatment, the topography of the aneurysm, or the occurrence of treatment related complications. The results of the logistical regression model demonstrated that the clinical score upon entry, and the occurrence of delayed ischemia were the only independent factors correlated with patient death. The prognostic factors affecting the degree of sequellae identified by the logistical regression model were the clinical score upon admission, age, treatment related complications, and pulmonary complications. CONCLUSIONS: Endovascular treatment of ruptured anterior circulation aneurysms with GDC, including MCA aneurysms, is associated with low morbidity and allows good overall outcomes in patients with subarachnoid hemorrhage. A better understanding of dependency factors associated with endovascular coiling will foster further technical advances in order to improve the treatment of small and medium sized ruptured aneurysms.

Analysis of Variance↗

[Lateral bulbar infarction due to intracranial dissection and subarachnoid haemorrhage].

INTRODUCTION: Intracranial vertebral artery dissecting aneurysms are a recognized cause of subarachnoid hemorrhage and the hemorrhagic recurrence risk after a first rupture of the dissecting aneurysm is high and of poor prognosis. However, when the dissection is discovered in a patient with vertebrobasilar territory ischemia, little is known about the risk of hemorrhagic rupture risk and there is no consensus on management. OBSERVATION: We report the case of a 49-year-old man who developed subarachnoid hemorrhage 48 hours after the occurrence of a latero-bulbar syndrome caused by a spontaneous dissection with occlusion of the right vertebral artery. The subsequent angiography showed a V4 dissecting aneurysm of the right vertebral artery which was treated by stenting and coiling without any complications. CONCLUSION: This case underlines the hemorrhagic risk of an intradural vertebral artery dissection and its possible progression to aneurysm. Subsequent angiographic imaging must be carefully examined to search for aneurysms which may require early specific treatment because of the high risk of recurrent bleeding.

Brain Infarction↗