PubMed Health⌕ Search

Biomedical subjects

A Brunick

Publications and source records attributed to A Brunick.

5 recordsLinked to original sources

Determination of the viremia threshold for dental cross-infection in a mouse model.

An animal model of dental virus transmission was developed using the lactate dehydrogenase-elevating virus (LDV) of mice to study cross infection. Mouse-to-mouse cross-infection was carried out by scaling the teeth of LDV-infected donor mice with dental instruments, immediately prior to using the contaminated instruments on the teeth of recipient indicator mice. The level of donor viremia was found to correlate with the rate of virus cross-infection, with a viremia threshold level of 10(7.5) ID50/ml observed for dental cross-infection. The blood volume transferred during dental cross-infection was approximately 10(-4) to 10(-5) ml, demonstrating the inefficiency of virus cross-infection, since deposition of about 1000 virions on dental instruments was associated with the threshold limit. Virus transferred during dental cross-infection rapidly entered the blood circulation, showing that dental cross-infection was not dependent on an oral infection. The results from these model studies predict the general inefficiency of dental instrument virus cross-infection, and a further reduced likelihood of dental cross-infection with appropriately cleaned instruments.

Animals↗

Effectiveness of ultrasonic cleaning of dental instruments.

PURPOSE: To quantitate blood contamination present on dental instruments used for routine prophylaxis and to assess the effectiveness of ultrasonic decontamination in reducing blood and virus contamination on dental instruments. MATERIALS AND METHODS: Human blood contamination present on dental instruments obtained after routine prophylaxis was analyzed using IgG as a blood marker. RESULTS: The estimated contaminating blood volume was found to normally range between 1.4 x 10(-6) to 2.0 x 10(-4) ml. Attempts to saturate the instruments with blood contamination suggested that the maximum possible retained blood volume was about 10-fold higher than the normal levels of contamination. Hand scrubbing of contaminated instruments was both relatively ineffective and inconsistent in removing blood contamination. Decontamination in an ultrasonic cleaner was more effective than hand washing, resulting in greater than a 100-fold reduction of blood contamination. Using a mouse model virus (lactate dehydrogenase-elevating virus, LDV), high levels of virus contamination of dental instruments and dental handpieces were achieved, as determined by assay of residual virus. Ultrasonic treatment reduced the level of virus contamination present on dental instruments by one million-fold, and virus contamination present in dental handpieces was reduced by one thousand-fold. These results provide quantitative estimations of the infection threat and its reduction by ultrasonication, posed by human-exposed dental instruments.

Animals↗

The cutting edge.

Explore the source record for details and available documents.

Dental Instruments↗