PubMed HealthSearch

Biomedical subjects

A C Kotcheff

Publications and source records attributed to A C Kotcheff.

2 recordsLinked to original sources

Model-based interpretation of complex and variable images.

The ultimate goal of machine vision is image understanding-the ability not only to recover image structure but also to know what it represents. By definition, this involves the use of models which describe and label the expected structure of the world. Over the past decade, model-based vision has been applied successfully to images of man-made objects. It has proved much more difficult to develop model-based approaches to the interpretation of images of complex and variable structures such as faces or the internal organs of the human body (as visualized in medical images). In such cases it has been problematic even to recover image structure reliably, without a model to organize the often noisy and incomplete image evidence. The key problem is that of variability. To be useful, a model needs to be specific-that is, to be capable of representing only 'legal' examples of the modelled object(s). It has proved difficult to achieve this whilst allowing for natural variability. Recent developments have overcome this problem; it has been shown that specific patterns of variability in shape and grey-level appearance can be captured by statistical models that can be used directly in image interpretation. The details of the approach are outlined and practical examples from medical image interpretation and face recognition are used to illustrate how previously intractable problems can now be tackled successfully. It is also interesting to ask whether these results provide any possible insights into natural vision; for example, we show that the apparent changes in shape which result from viewing three-dimensional objects from different viewpoints can be modelled quite well in two dimensions; this may lend some support to the 'characteristic views' model of natural vision.

Form Perception

An automated method for assessing routine radiographs of patients with total hip replacements.

This paper describes a new, fully automated method of locating objects on radiographs of patients with total joint replacements (TJRs). A statistical computer model, known as an active shape model, was trained to identify the position of the femur, pelvis, stem and cup marker wire on radiographs of patients with Charnley total hip prostheses. Once trained, the model was able to locate these objects through a process of automatic image searching, despite their appearance depending on the orientation and anatomy of the patient. Experiments were carried out to test the accuracy with which the model was able to fit to previously unseen data and with which reference points could be calculated from the model points. The model was able to locate the femur and stem with a mean error of approximately 0.8 mm and a 95 per cent confidence limit of 1.7 mm. Once the model had successfully located these objects, the midpoint of the stem head could be calculated with a mean error of approximately 0.2 mm. Although the model has been trained on Charnley total hip replacements, the method is generic and so can be applied to radiographs of patients with any TJR. This paper shows that computer models can form the basis of a quick, automatic method of taking measurements from standard clinical radiographs.

Computer Simulation