Simultaneous MRI tagging and through-plane velocity quantification: a three-dimensional myocardial motion tracking algorithm.

A tracking algorithm was developed for calculation of three-dimensional point-specific myocardial motion. The algorithm was designed for images acquired with simultaneous magnetic resonance imaging (MRI) grid tagging and through-plane velocity quantification. The tagging grid provided the in-plane motion while the velocity quantification measured the through-plane motion. In four healthy volunteers, the in vivo performance was evaluated by comparing the systolic through-plane displacement with the displacement of tagging-grid intersections in long-axis images. The correlation coefficient was 0.93 (P < 0.001, N = 183). A t-test for paired samples revealed a small underestimation of the through-plane displacement by 0.04 +/- 0.09 cm (mean +/- SD, P < 0.001) on an average displacement of 0.77 +/- 0.23 cm toward the apex. The authors conclude that three-dimensional point-specific motion tracking based on simultaneous tagging and velocity quantification is competitive with other methods such as tagging in mutually orthogonal image planes or quantification of three orthogonal velocity components.

Algorithms

Morphologic and functional evaluation of coronary artery bypass conduits.

There is clear evidence in the literature that conventional spin-echo and gradient-echo magnetic resonance imaging (MRI) is capable of assessing patency of coronary artery vein grafts. With more recently introduced breath-hold two-dimensional (2D) and contrast-enhanced 3D techniques, the predictive accuracy has further improved, with sensitivities and specificities in the 90% range. Limitations arise with regard to assessing obstructive disease and evaluating distal segments of sequential grafts, due to insufficient spatial resolution, low signal-to-noise ratio, and cardiac motion. Imaging of arterial grafts is complicated by the metallic clip artifacts. Adding information on graft flow patterns and flow reserve using velocity-encoded cine MRI may help to reduce some of the problems. Clinically, these functional measurements may become of use in non-invasive monitoring of gradually increasing graft narrowing. However, apart from a few exceptions, most patients undergo evaluation of their grafts because they are considered for a re-intervention by angioplasty or coronary artery bypass graft surgery. In these cases information on the status of the native coronary arteries is required. A broader clinical use of MRI in the evaluation of patients with coronary artery bypass grafts may therefore only be expected with further improvement in MR techniques for coronary angiography. J. Magn. Reson. Imaging 1999;10:734-740.

Blood Vessel Prosthesis

Recognition of infarct localization by specific changes in intramural myocardial mechanics.

BACKGROUND: After transmural myocardial infarction (MI), changes occur in intramural myocardial function. This has been described in anterior MI only. The aim of this study was to determine the relation between variable infarct locations and intramural deformation in patients with a first MI. METHODS: Forty patients (33 men and 7 women aged 57 +/- 11 years) with different infarct-related coronary arteries (25 left anterior descending, 7 circumflex, and 8 right coronary) were studied 6 +/- 3 days after infarction with magnetic resonance tissue tagging and 2-dimensional finite element analysis of myocardial deformation. Short-axis tagged images were acquired at base, mid, and apical level. Intramural deformation was measured in 6 circumferential segments per level. Results were compared with 9 age-matched healthy controls. RESULTS: Each infarct area demonstrated a significant reduction of intramural deformation. At mid-ventricular level, segments with maximum impaired intramural function were the anteroseptal segment for left anterior descending-related MI (stretch: 16% vs 33% for controls, P <.001), the posterolateral segment for related MI (stretch: 20% vs 34%, P <. 01); and the inferior segment for right coronary artery related MI (stretch: 18% vs 25%, P =.082). In these infarct segments, the intramural regional systolic stretch was more circumferentially oriented compared with radially oriented stretch in the same segments in controls (P <.05). CONCLUSION: The infarct area can be recognized by a specific spatial pattern of intramural deformation. In infarcted compared with noninfarcted myocardium, deformation is significantly reduced and systolic stretch deviates from the radial direction. Left anterior descending related infarcts were found to have larger regional differences in intramural deformation than circumflex or right coronary artery related MI of enzymatically the same size.

Aged

Myocardial perfusion imaging: clinical experience and recent progress in radionuclide scintigraphy and magnetic resonance imaging.

In the past 20 years, radionuclide scintigraphy has proven to be a sensitive clinical tool in the assessment of myocardial perfusion abnormalities. Magnetic resonance imaging may also be used to study myocardial perfusion, but its potential value still has to emerge in the clinical setting. This review addresses the potential and achievements of both methods in clinical cardiology.

Animals

A practical approach to MRI of coronary artery bypass graft patency and flow.

Direct visualization of coronary artery bypass grafts can be obtained non-invasively by magnetic resonance imaging. Several studies demonstrated a high sensitivity and somewhat lower specificity for detection of vein-graft patency, using the conventional spin-echo and gradient-echo techniques. In addition, the true functional status can be assessed by determining the flowrate within the graft using phase velocity mapping. Important limitations of the previously applied techniques include the inability to accurately evaluate the different segments of jump grafts and the presence of graft stenoses. Further improvement is to be expected from the recent introduction of breath-hold imaging sequences and the forthcoming introduction of bloodpool-avid contrast agents.

Coronary Artery Bypass

Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease.

AIMS: The accuracy of magnetic resonance angiography in detecting proximal coronary artery stenoses is unclear. We postulated that fast magnetic resonance angiography is capable of (1) imaging proximal coronary arteries, and (2) detecting stenoses of > or = 50% of their luminal diameter. METHODS AND RESULTS: Thirty-five patients, referred for analysis of angina pectoris, underwent both conventional angiography and magnetic resonance angiography of coronary arteries. A fast k-space segmented gradient-echo technique was used during breath-holds. Two observers, blinded to the results of conventional angiography, independently analysed the magnetic resonance studies for (1) length of visualized segments, and (2) presence of signal voids indicative of stenoses. From 140 proximal arteries, 15 (11%) were excluded because of incomplete imaging or degraded image quality. Mean length of the visualized segments was 9 +/- 4 mm for the left main, 62 +/- 16 mm for the left anterior descending, 21 +/- 9 mm for the left circumflex and 89 +/- 32 mm for the right coronary artery. Sensitivity for detecting > or = 50% luminal diameter stenoses was 0.00 for the left circumflex, 0.53 for the left anterior descending coronary artery, 0.71 for the RCA and 1.00 for the left main artery. Specificity varied from 0.73 for the left anterior descending coronary artery to 0.96 for the left circumflex. Inter-observer agreement was 0.90. CONCLUSION: Thus, segmented magnetic resonance angiography is capable of non-invasive imaging of proximal coronary anatomy. Its good accuracy in detecting left main coronary artery disease, intermediate accuracy in detecting right coronary artery and left anterior descending coronary artery stenoses, and low accuracy in detecting left circumflex lesions fit within a range of sensitivities and specificities found by others. Further technical advances are necessary to make the technique clinically robust.

Coronary Angiography

Value of magnetic resonance imaging in assessing patency and function of coronary artery bypass grafts. An angiographically controlled study.

BACKGROUND: Previous studies have demonstrated the high sensitivity and moderate specificity of standard magnetic resonance (MR) spin-echo (SE) and gradient-echo (GE) techniques in predicting the patency of coronary artery bypass grafts. These techniques, however, do not provide quantitative information. Therefore, the objectives of this study were first to investigate whether MR cine GE images, performed in addition to standard SE images, have additional value for the assessment of graft patency and second to assess the graft function by measuring the flow pattern and flow rate with MR phase velocity imaging. METHODS AND RESULTS: Forty-seven patients with previous histories of coronary artery bypass grafting underwent angiography and MR SE and cine GE phase velocity imaging. SE and GE images were evaluated by three independent observers blinded to the angiographic results. The spatial mean velocity and volume flow were measured and repeated for each image at consecutive 50-millisecond intervals throughout the cardiac cycle. The 47 patients had 98 proximal aortotomies, of which 60 were single and 38 sequential grafts. Seventy-three grafts were patent; 25 were occluded. Eighty-four grafts (86%) were eligible for comparison of the results of SE and GE images. Assessment of patency was inconclusive on SE images in 7 grafts (5 occluded by angiography) and on GE images in 7 grafts (2 occluded). A comparison of the results of contrast angiography and SE and GE MR imaging techniques showed that both techniques had a high sensitivity (both 98%) and somewhat lower specificity (85% and 88%, respectively) for graft patency. Combined analysis of the SE and GE images did not improve the accuracy. The strength of the interobserver agreement on GE images was good (kappa = 0.66), whereas on SE images the agreement was moderate (kappa = 0.51). Adequate MR phase velocity profiles were obtained in 62 (85%) of the 73 angiographically patent grafts. Graft flow was characterized by a balanced biphasic forward flow pattern. The volume flow of sequential grafts to 3 regions (136 +/- 106 mL/min) was significantly higher than in single grafts (63 +/- 41 mL/min, P < .01). CONCLUSIONS: Considering the good interobserver agreement and the 85% success rate of quantitative flow measurements, cine GE phase velocity mapping is a promising clinical tool in the noninvasive assessment of graft patency and function.

Aged

Transesophageal cardiac pacing during magnetic resonance imaging: feasibility and safety considerations.

The feasibility and safety of transesophageal cardiac pacing during clinical MRI at 1.5 Tesla is considered. An MRI compatible pace catheter was developed. In vitro testing showed a normal performance of the pulse generator, image artifacts that extended less than 11 mm from the catheter, and a less than 5% increase in noise. Cardiac stimulation induced by MRI was not observed and, theoretically, is not expected. Potentially, tissue around the catheter tip may become heated. This heating (delta tau) was monitored. Eight dogs were exposed to MRI during pacing. For low RF radiation exposure, a time-averaged squared B1 field below 0.08 p tau 2 (SAR < 0.03 W/kg), delta tau was below 1 degree C. For high RF radiation exposure, but at normal RF radiation specific absorption rate (0.4 W/kg) delta tau was 5 degrees C. Thus, transesophageal atrial pacing during MRI at low RF exposure seems to be possible to perform cardiac stress studies or to correct unstable heart rates.

Animals

Assessment of flow in the right human coronary artery by magnetic resonance phase contrast velocity measurement: effects of cardiac and respiratory motion.

Flow in the human right coronary artery was determined using magnetic resonance phase contrast velocity quantification. Two methods were applied to reduce respiratory motion: Imaging during breath holding, which is fast, and retrospective respiratory gating, which has a high temporal resolution (32 ms) in the cardiac cycle. Vessel cross-sectional area, through-plane velocity, and volume flow were determined in six healthy subjects. In-plane vessel displacement during the cardiac cycle, caused by cardiac contraction, was about 2-4 mm within a time frame of 32 ms in systole and early diastole. The motion resulted in blurring of images obtained during breath holding caused by the large acquisition time window (126 ms) within the cardiac cycle. Therefore, only with a high temporal resolution correct velocity images over the entire cardiac cycle could be obtained. The time- and cross-sectionally averaged velocity was 7 +/- 2 cm/s, and the volume flow was 30 +/- 10 ml/min.

Adult

Assessment of acute myocardial infarction in man with magnetic resonance imaging and the use of a new paramagnetic contrast agent gadolinium-BOPTA.

To assess the feasibility of and characterize the new paramagnetic contrast agent gadolinium-BOPTA/dimeglumine (Gd-BOPTA) to detect acute myocardial infarctions with MR imaging, 24 patients (53.3 +/- 8.3 yr) were examined 9.3 +/- 3.6 days after a first myocardial infarction. Short-axis T1-weighted and T2-weighted MR imaging was performed at three slice levels. T1-weighted images were obtained before, immediately after, 15, 30, and 45 min after injection. Patients received either 0.05 or 0.1 mmol/kg body weight Gd-BOPTA. Images were qualitatively and quantitatively analyzed. Two patients showed no signs of infarction on T2-weighted images as opposed to contrast-enhanced T1-weighted images. Contrast-to-noise ratio was not affected by the dosage level. Signal intensity (SI) of normal to infarcted myocardium was significantly improved by both dosages (p < .0005) but a dosage of 0.05 mmol/kg produced significantly higher SI inf/norm (1.42 +/- 0.07 vs. 1.34 +/- 0.06, respectively, p = .015). SI of normal and infarcted myocardium enhanced immediately after administration of 0.05 mmol/kg (29.3 +/- 5.1% and 53.8 +/- 9.6% respectively), which decreased thereafter to 5.3 +/- 4.8% and 40.2 +/- 8.5% respectively, at 45 min (p < .002 for normal myocardium). SI enhancement immediately after 0.1 mmol/kg Gd-BOPTA showed no decrease within the first 45 min. Gd-BOPTA enables the detection of myocardial infarction. Optimal infarct delineation is achieved from 15 to 45 min after administration of 0.05 mmol/kg body weight Gd-BOPTA. Gd-BOPTA at 0.05 mmol/kg does improve image quality as measured by contrast-to-noise ratio and SI enhancement as compared to 0.10 mmol/kg.

Adult

Quantification of coronary artery bypass graft flow by magnetic resonance phase velocity mapping.

OBJECTIVES: Determination of the true coronary artery bypass graft function requires quantification of the flow rate within the graft. The purpose of the present study was to assess the feasibility of characterizing and quantifying graft flow by magnetic resonance phase velocity mapping. MATERIALS AND METHODS: Twenty-seven patients with 41 angiographically patent coronary artery bypass grafts underwent electrocardiographically gated magnetic resonance phase velocity mapping. Imaging was performed at 0.6 Tesla using a surface coil. Velocity maps of the bypass grafts were obtained throughout the cardiac cycle with a temporal resolution of 50 ms and a spatial resolution of 1.9 x 1.2 x 5 mm3, allowing calculation of phasic and mean graft flow. RESULTS: Adequate flow measurements were obtained in 84% (41 out of 49) of the grafts. Coronary artery bypass graft flow was characterized by a biphasic pattern with a first peak during systole and a second peak during diastole. Average maximum systolic and diastolic velocities over the cross-section of the grafts were 14 +/- 8 cm/s and 15 +/- 9 cm/s, respectively. Mean coronary artery bypass graft cross-sectional area was 0.28 +/- 0.13 cm2. Mean volume flow was 87 +/- 59 ml/min. CONCLUSION: Flow in coronary artery bypass grafts can be characterized and measured noninvasively by magnetic resonance phase velocity mapping.

Blood Flow Velocity

Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography.

OBJECTIVE: MR coronary angiography is most often performed using two-dimensional techniques. Although three-dimensional (3D) acquisitions do have important advantages, they take too long for a single breath-hold and are thus susceptible to respiratory motion artifacts. The purpose of this study was to investigate the accuracy of a unique respiratory-gated 3D MR angiographic technique in identifying the proximal coronary arteries in patients suspected of having coronary artery disease. In addition, we investigated the capability of this technique to detect proximal stenoses. SUBJECTS AND METHODS: We performed a prospective blinded study in 20 patients who were referred for conventional coronary angiography. A cardiac-gated 3D gradient-echo sequence with fat suppression was used. Retrospective respiratory gating was performed using navigator echoes of the diaphragm position. Using multiplanar reformatting, two independent readers blindly analyzed the data sets for visualization of major coronary arteries, lengths of imaged segments, and detection of significant stenoses (> 50% occlusion of the luminal diameter by conventional angiography). RESULTS: Seventy-seven of 80 (96%) coronary arteries were positively identified. In one patient, an anomalous coronary anatomy was readily identified and confirmed by conventional angiography. The average lengths of the imaged segments of the right, left main, left anterior descending, and left circumflex coronary arteries were 58 +/- 13 mm, 9 +/- 5 mm, 59 +/- 16 mm, and 24 +/- 10 mm, respectively. Overall sensitivity for the detection of stenoses was low (38%), with a specificity of 95%. Interobserver agreement was 0.92, with a kappa value of 0.65. CONCLUSION: Respiratory-gated 3D MR angiography allows accurate identification of proximal coronary arteries and may be valuable for 3D imaging of coronary anomalies. Further technical improvements are required to enhance the value of the technique in detecting stenoses.

Adult

Coronary imaging using MRI.

Without use of ionizing radiation and injection of contrast material magnetic resonance imaging (MRI) can be applied to generate signal from flowing blood and create tomographic images of the bloodstream in coronary arteries, which resemble conventional contrast enhanced X-ray angiograms. The tortuosity, small diameter and motion of the coronary arteries provided technically demanding problems, which had to be solved before MR coronary angiography became realistic. Faster pulse sequences, dedicated radiofrequency receiver coils, cardiac and respiratory gating techniques were introduced and are still in the process of constant development to improve the quality of the images. To date, most clinical experience has been obtained using 2D approaches necessitating repetitive breath-holds to encompass the coronary artery tree. A substantial part of the proximal and middle parts of the coronary arteries can be visualized, which has proven to be accurate in identifying anomalous coronary anatomy and patency of proximal coronary artery bypass grafts. However, the technique is currently not sensitive enough to reliably detect coronary artery stenoses. Another approach is a single acquisition respiratory gated 3D technique which is less operator and patient dependent, requires less imaging time for an entire coronary protocol and is more comfortable for the patient than the 2D breath-hold approach. Initial experience demonstrates the capability to identify the major epicardial coronary vessels. But here too, further development is required to demonstrate coronary stenoses. A unique feature of MR imaging is the feasibility to non-invasively quantitate flow in the coronary arteries. This offers the potential to selectively determine the flow reserve of coronary arteries and to assess the functional and physiological implications of moderately severe stenoses. It can be envisaged that, although currently not apt to replace conventional coronary angiography, MR coronary angiography and flow measurement will become of use in the evaluation of specific, well defined clinical issues in coronary artery disease.

Artifacts

Magnetic resonance angiography of anomalous coronary arteries. A new gold standard for delineating the proximal course?

BACKGROUND: The clinical significance of anomalously originating coronary arteries depends on their proximal course. Diagnosis of this course by conventional x-ray coronary angiography alone may be equivocal. We postulated that with fast magnetic resonance (MR) angiography, accurate detection of anomalous coronary arteries and unambiguous delineation of their proximal course is feasible. METHODS AND RESULTS: In a selected group of 38 patients, 19 of them having an anomalously originating coronary artery, a fast MR angiographic technique was used to study the proximal coronary anatomy. Blinded analysis of randomly ordered MR studies was performed independently by two observers. Both origin and proximal course of the coronary arteries were defined. Two cardiologists reviewed all x-ray coronary angiograms. After the separate analyses, a final consensus result was defined for each patient. In 37 patients, successful MR coronary angiography could be performed. Interobserver agreement for determining both origin and proximal course was 100%. An x-ray coronary angiogram was available in 36 patients. In 3 patients (all with an anomalous left main coronary artery originating from the right aortic sinus), there was disagreement about the proximal course between the results of MR and x-ray coronary angiography. Review of these cases demonstrated that MR angiography had unambiguously visualized the proximal coronary artery course, whereas the results of x-ray angiography had been equivocal. Thus, sensitivity and specificity for detecting anomalous coronary arteries and delineating their proximal course were 100%. CONCLUSIONS: These data suggest that fast MR angiography is highly accurate in determining the origin and delineating the proximal course of anomalous coronary arteries, even in those cases in which x-ray coronary angiographic diagnosis is difficult or even erroneous.

Coronary Angiography

In vivo validation of magnetic resonance blood volume flow measurements with limited spatial resolution in small vessels.

The accuracy of magnetic resonance phase contrast volume flow measurements in small blood vessels is expected to be smaller than in large vessels, because of partial volume effects at the vessel boundary. Accuracy was validated in the dog femoral artery, diameter 3.5 +/- 0.7 mm, using an ultrasonic transit-time flowmeter (TT). The number of pixels per vessel diameter (ND) ranged from 1.6 to 4.8. The vessel cross-section was determined using a threshold in the magnitude image. Between the two methods the correlation coefficient was 0.95 (range 10-200 ml/min). The proportional difference (PD), (QTT-QMR)/1/2(QTT+QMR), was 0.8%, showing no systematic difference between the methods. The PDs standard deviation was 27%, and 19% for flow rates above 30 ml/min. Only a significant decrease of the PDs variance was found at the highest ND values, suggesting other sources of error than partial volume effects. It is concluded that with an ND value of about 3, accurate blood volume flow rates can be determined.

Animals

Semiquantitation of regional myocardial blood flow in normal human subjects by first-pass magnetic resonance imaging.

The purpose of this study was to investigate the feasibility of first-pass MR imaging for measurement of regional myocardial blood flow in human beings. The first pass of the contrast agent Gd-DTPA through the myocardium was imaged in 12 normal volunteers with an ECG-gated Turbo-Flash sequence. The MTT of the contrast agent through the myocardium after a bolus injection was derived from curves of SI versus time. The bolus was injected through an intravenous catheter, which was advanced to the central venous position (preferably the right atrium). To investigate myocardial input function, different bolus concentrations and catheter positions were compared. It is concluded that first-pass MR imaging is feasible in human subjects when a central injection of 0.03 mmol/kg of Gd-DTPA is applied. MTT values were similar throughout the myocardium of normal subjects at rest, reflecting normal perfusion. Absolute values of MTT were related to the myocardial input.

Adult

Protocol for two-dimensional magnetic resonance coronary angiography studied in three-dimensional magnetic resonance data sets.

The purpose of this study was to develop a standardized method of 2D MRA of the proximal 50 mm of the major epicardial coronary arteries. Therefore the efficacy of fixed imaging planes (transverse, coronal, sagittal, 30-degree RAO equivalent, and 60-degree LAO equivalent) in imaging coronary arteries was compared to that of oblique planes defined by the operator on a previously obtained image. 3D data sets obtained by a respiratory-gated 3D MRA method in eight patients with a mean age of 57 years were studied by multiplanar reformatting. Efficacy of planes was expressed as an IOE. Fixed transverse imaging planes proved to be equally efficacious as operator-defined planes in imaging the left main (IOE 2.2 +/- 1.0 vs 2.2 +/- 0.9, p = NS) and LAD (IOE 6.0 +/- 1.9 vs 8.2 +/- 2.0, p = NS). Operator-defined planes were superior to fixed imaging planes in imaging the RCA (IOE 6.3 +/- 1.2 vs 3.5 +/- 1.2, p < 0.001) and the LCx (IOE 6.2 +/- 2.3 vs 4.8 < 2.3, p < 0.05). On the basis of these results, a standardized 2D MRA protocol for the proximal coronary arteries was proposed. Pitfalls in interpretation of coronary MRA images were discussed.

Aged