Application of stereophotogrammetry to total body three-dimensional analysis of human tremor.

This work aims at verifying the possibility of investigating joint rotations, with amplitude and frequency ranges typical of pathological human tremor, using commercially available stereophotogrammetric systems together with signal processing techniques. A rotating disk is used as a mechanical tremor simulator to test the ability of the system to track known marker trajectories both in a large and a small calibrated volume. The performances of standard discrete Fourier transform (DFT) and autoregressive techniques are also evaluated and compared in the signal spectrum estimation. Results obtained from a pathological test subject and their dependence on the processing techniques adopted are also presented. The use of stereophotogrammetry and of the proposed signal spectrum estimation technique allow to quantify both frequency and amplitude content of three-dimensional (3-D) rotations of many human joints simultaneously and therefore to isolate the contribution of each joint to the whole body tremor.

Aged↗

[Echography of the shoulder with the patient supine in the diagnosis of rotator cuff rupture].

We report a new method for shoulder sonography (US): the patient lies supine and his/her arm is positioned so as to optimize tendon depiction. The supraspinatus tendon, which is the most frequently involved structure in rotator cuff tears, is studied with the patient's arm dropped, elbow extended and forearm prone. Our series consisted of 49 surgical patients (arthroscopy in 16 and open surgery in 33 patients): US sensitivity in tear depiction was 84.8%, specificity 100% and accuracy 89.8%. Medium-small tears appeared as transonic areas within tendon substance and/or tendon focal thinning. Large tears appeared as: (a) missed or markedly thinned rotator cuff, with deltoid muscle approximation to the humeral head surface, (b) plenty of fluid collected around bulky tear margins. The US images of 36 patients were then reviewed and the details discussed. A new sign was observed in medium-small tears, that is a sharp hyperechoic band encircling the humeral cartilage (the compass sign). In conclusion, we believe that US performed with the patient in supine recumbency is easier to perform and provides a bigger field of view of the supraspinatus tendon; it also permits to keep stretched rotator cuff, with consequent image quality improvement.

Adult↗

Optimization and smoothing techniques in movement analysis.

This paper deals with accurate estimation of the degrees of freedom (DOF) of a body segment, starting from the trajectories of clusters of markers acquired with a suitable measurement system. The most commonly employed estimation procedures involve two sequential steps, a trajectory smoothing algorithm and a DOF reconstruction routine. Three optimized smoothing and reconstruction schemes are described, analyzed and tested and their performances are compared with each other and with those of a more traditional technique which contains no optimization criteria. All three schemes include an iterative, weighted-least-squares DOF reconstruction routine and a self-tuning, zero-phase-shift, 4th-order Butterworth filter. Both routines are extensively described and validated on the basis of numerically-simulated marker trajectories. Test results, analyzed on a statistical basis, show that the use of an optimization routine provides a visible improvement in DOF reconstruction. This performance has also been confirmed using stereophotogrammetric data collected on a subject wearing an external fracture fixation device which provides reference values for the bone DOF. Angular DOF estimated applying the optimized method to skin technical clusters are much closer to the reference values than the non-optimized values. Smoothing of data further improves the reconstruction accuracy while a far less crucial role is played by the order in which smoothing and reconstruction routines are applied.

Algorithms↗

Mechanical validation of whole bone composite femur models.

Composite synthetic models of the human femur have recently become commercially available as substitutes for cadaveric specimens. Their quick diffusion was justified by the advantages they offer as a substitute for real femurs. The present investigation concentrated on an extensive experimental validation of the mechanical behaviour of the whole bone composite model, compared to human fresh-frozen and dried-rehydrated specimens for different loading conditions. First, the viscoelastic behaviour of the models was investigated under simulated single leg stance loading, showing that the little time dependent phenomena observed tend to extinguish within a few minutes of the load application. The behaviour under axial loading was then studied by comparing the vertical displacement of the head as well as the axial strains, by application of a parametric descriptive model of the strain distribution. Finally, a four point bending test and a torsional test were performed to characterize the whole bone stiffness of the femur. In all these tests, the composite femurs were shown to fall well within the range for cadaveric specimens, with no significant differences being detected between the synthetic femurs and the two groups of cadaveric femurs. Moreover, the interfemur variability for the composite femurs was 20-200 times lower than that for the cadaveric specimens, thus allowing smaller differences to be characterized as significant using the same simple size, if the composite femurs are employed.

Biomechanical Phenomena↗

A minimal parametric model of the femur to describe axial elastic strain in response to loads.

Evaluating the state of stress/strain for a given geometry and load in femurs can be done both experimentally, measuring strain at a limited number of locations, and theoretically with finite element models. Another approach is to describe the state of strain with a few synthetic indices. For this purpose the reverse elastic problem (i.e. bone parameters are estimated given the strain distribution and loads) needs to be solved as opposed to the finite element direct problem. Such reverse models can be then used: (1) to describe simply the strain distribution by means of few synthetic indices; (2) to explain the state of strain; and (3) to predict the strain distribution under different loading conditions. Various linear models, characterized by two to five bone related parameters, were tested on (1) 12 femurs, (2) a finite element model, and (3) data taken from the literature, for a total of 43 loading cases. Three and four-parameter models were able to fit the experimental strain distributions with mean squared residuals smaller than 5% of the strain range. The consistency of the model was proved by the repeatability of the parameters estimate for identical femurs. Furthermore, the bone-related coefficients were able to detect the stiffening effect of the implantation of an uncemented stem. Finally, the model can be used for predictive purposes if the parameter estimates are used with different loading conditions.

Biomechanical Phenomena↗

Analytic solution of the Variable-Volume Double-Pool urea kinetics model applied to parameter estimation in hemodialysis.

An analytic solution of the Variable-Volume Double-Pool urea kinetics model and its application to the estimation of clinically relevant parameters of the patient-machine system, are presented. These include the urea distribution volume and generation rate and the mean dialyzer clearance. The estimation of these parameters is based on the assumption of constant values for the diffusion coefficient between the two pools and the intra-extracellular volume ratio. Results obtained by computer simulations show that the effect of a +/- 50% variation of these parameters influences the estimates less than standard measurement errors. Starting from these results, four methods to in vivo estimate the urea distribution volume and generation rate from blood samples are compared. Two methods are based on the analytic solution of the double-pool model using seven samples (reference method) or three samples (new clinical method). The remaining methods are based on urea mass-balance and are largely used in the clinical practice. These last techniques differ from each other for the blood sample taken at the end of the treatment or 30 min later. The results obtained from hemofiltration sessions show that the urea generation rate is accurately estimated by all methods. The total distribution volume is still accurately estimated by the new clinical method while it is systematically underestimated by the urea mass-balance when the blood sample at the end of dialysis is used. Instead, a high overcompensation results using the blood sample taken 30 min after the end of dialysis. Finally, the new clinical method also provides reliable estimates for the dialyzer clearance starting from only three blood samples all taken during dialysis.

Algorithms↗

Sensitivity analysis for estimating urea kinetics parameters during hemodialysis.

In this paper a time-varying volume, double-pool urea kinetics model is considered and a sensitivity analysis is carried out to determine those patient parameters that have greater influence on the time course of blood urea nitrogen concentration (BUN) during and between dialysis treatment. The model parameters include the urea generation rate, the initial distribution volume of the urea, the ratio between intracellular and extracellular volumes, and the mass transfer coefficient between the two pools. The analysis demonstrates that BUN is highly sensitive to the urea generation rate and total distribution volume whereas it is influenced by the remaining parameters to a much lesser extent. In addition, the location of the absolute maxima of BUN sensitivity functions suggests the rational placement of a reduced number of blood samples that may still allow sufficiently accurate estimates for the parameters of clinical interest, such as the urea generation rate, total distribution volume, and the ratio between intracellular and extracellular volumes. This conclusion has been confirmed by simulation studies where parameter estimation has been performed with a varying number of observation points.

Blood Urea Nitrogen↗

Two new algorithms for tracking arterial parameters in nonstationary noise conditions.

Two new algorithms with reduced sensitivity to the changing environment are applied to tracking arterial circulation parameters. They are variants of the Least-Squares (LS) algorithm with Variable Forgetting factor (LSVF), and of the Constant Forgetting factor-Covariance Modification (CFCM) LS algorithm, devised to overcome their main practical deficiencies related to noise level sensitivity and the high number of design variables, respectively. To this end, adaptive mechanisms are incorporated to estimate observation noise variance in LSVF and the rate of change for the different parameters in CFCM. Specific computer simulation experiments are presented to compare their effectiveness with the original counterparts and to provide guidelines for their optimal tuning at different noise levels. Moreover, algorithm performance degradation, consequent on changes in the noise level compared to that assumed during the tuning phase, is analyzed. In particular, it is shown that, when the noise level changes with respect to the tuning value, the new LSVF algorithm is much more robust than the original one, whose performance degrades rapidly. The new CFCM algorithm is characterized by a reduced number of design variables with respect to its original counterpart. Nevertheless, it can be preferred only when low noise signals are used for estimation.

Algorithms↗

Influence of flow pattern on the parameter estimates of a simple breathing mechanics model.

The first-order model of breathing mechanics is widely used in clinical practice to assess the viscoelastic properties of the respiratory system. Although simple, this model takes the predominant features of the pressure-flow relationship into account but gives highly systematic residuals between measured and model-predicted variables. To achieve a better fit of the entire data set, an approach hypothesizing deterministic time-variations of model parameters, summarized by information-weighted histograms was recently proposed by Bates and Lauzon. The present study uses flow and pressure data measured in intensive care patients to evaluate the real potential of this approach in clinical practice. Information-weighted histograms of the model parameters, estimated by an on-line identification algorithm, were first constructed by taking into account the parameter percentage standard deviations. Then, the influence of the respiratory flow pattern on the calculated histograms was evaluated by the Kolmogorov-Smirnov statistical test. The results show that the method gives good reproducibility under stable experimental conditions. In addition, for a given airflow waveform, an increase in respiratory frequency shifts the histograms representing time-varying viscous properties strongly versus lower values, whereas it shifts the histograms representing time-varying elastic properties slightly versus higher values. On the other hand, the same histograms were highly dependent on the airflow waveform, especially for the viscous properties. Even in a limited experimental work, in all the conditions considered, the method provides results which agree well with the physiological knowledge of nonlinear and multicompartment behavior of respiratory mechanics.

Algorithms↗

On-line estimation and prediction of urea kinetics during hemodialysis: a simulation approach.

A new method for the on-line estimation of urea kinetic parameters from blood urea concentration (BUN) continuously measured during a dialysis session is proposed. The method, based on the variable-volume double-pool model, is evaluated through a simulation approach in order to easily consider a large set of well-controlled test conditions. The model is characterized by six parameters, knowledge of which enables early prediction of the end dialysis urea concentration and the dose of dialysis. The sensitivity of the model predicted BUN with respect to the parameters was first analyzed to investigate which can be reliably estimated from blood urea measurements taken at a suitable rate. This analysis showed that the model predicted BUN is highly sensitive to the initial blood urea concentration and to the dialyzer clearance, normalized with respect to the total initial distribution volume, while it is scarcely influenced by the normalized ultrafiltration and urea generation rates. The new on-line estimation technique keeps these two last parameters constant and takes advantage of an original analytic solution of the second order urea kinetics. The results of the estimation process on realistic simulated data showed that the proposed method provides early and reliable estimates of the normalized clearance and of the end dialysis concentration. The transcellular mass transfer coefficient and the intra-extra cellular volume ratio can also be estimated, although with less accuracy. Moreover, it was shown that the use of the single-pool model, instead of the double-pool one, provides systematic errors on the estimates.

Algorithms↗

Comparative evaluation of different methods to estimate urea distribution volume and generation rate.

Eight methods to estimate urea distribution volume and generation rate from blood urea samples measured in dialysis patients are reviewed. An analytical solution has been provided for a double-pool variable volume kinetic model to allow for faster and more accurate simulation and identification. The reliable parameter estimates provided by the double-pool kinetic model starting from seven samples, were assumed as references for the estimates obtained by the remaining methods. These include three kinetic models and four methods based on urea mass-balance. In particular, the estimation techniques differ in the number of compartments where urea is assumed distributed (double- and single-pool) or in the number of blood urea samples. Among the methods based on mass-balance, two techniques neglecting the weight loss or the urea generation during dialysis, were also analysed. The results obtained during hemofiltration sessions using three samples, usually available in clinical practice at the beginning and at the end of dialysis, demonstrate that a new method based on double-pool kinetics provides, on average, the most reliable estimates. Moreover, methods belonging to a single pool view and including both weight loss and urea generation during dialysis seem to underestimate by 1 divided by 2 liters the urea distribution volume. However, neglecting the weight loss or the urea generation can overcompensate this error, resulting in a significant overestimation of the distribution volume. Finally, it has been experimentally proved that the single-pool kinetic methods overestimate the urea production rate, while techniques based on mass balance provide more reliable values.

Adult↗

Comparison of algorithms for tracking short-term changes in arterial circulation parameters.

Three recursive methods especially suited for identification of systems with rapidly changing parameters are applied to tracking of the viscoelastic properties of the systemic arterial bed. These methods include two least squares (LS) algorithms with constant or variable forgetting factor (RLS and LSVF) and a LS algorithm incorporating both a constant forgetting factor and covariance modification (CFCM). The methods are presented in a unified framework and their sensitivity with respect to the design variables is investigated using noisy data from computer simulations. All analysed methods have shown themselves to be able to satisfactory track rapid changes in peripheral resistance. The LSVF method, which offers slightly better performances than the classical RLS, may be preferred when calculation efficiency is the prime requirement. The CFCM algorithm, although maintaining reasonable simplicity, shows the best tracking ability also on varying of the noise sequence.

Algorithms↗

Real-time tracking of parameters of lung mechanics: emphasis on algorithm tuning.

We consider the problem of tracking rapid changes in the viscous and elastic properties of the respiratory system by using mouth flow and transpulmonary pressure data measured during mechanical ventilation. A recursive least-squares algorithm with adjustable compensator is used for online estimation of an R-C model of the breathing mechanics. Specific simulation experiments are presented to provide guidelines to select suitable values for the key variable, which controls the compromise between tracking ability and noise sensitivity. The results obtained confirm the critical role of the optimum tuning in relation to the noise level. Experimental results obtained from data measured on mechanically-ventilated dogs, in which respiratory distress syndrome was intravenously induced by oleic acid, demonstrate that the tuned algorithm is able to track appropriately both the viscous and elastic properties of lung mechanics. Parameter estimates are consistent with those obtained by standard and robust offline algorithms and their time course is in qualitative agreement with known physiopathological behaviour.

Airway Resistance↗

Sensitivity analysis of the systemic circulation with a view to computer simulation and parameter estimation.

A sensitivity analysis study has been performed on a seven-parameter model of the systemic vascular bed in order to obtain structure reductions appropriate for simulation and estimation. This analysis considers separately the systolic and diastolic transfer functions between arterial and venous pressures in order to divide a non-linear problem in two distinct linear problems. The results obtained refer to nominal parameter values corresponding to normal circulatory conditions in man and supply guide-lines for an application-oriented selection of reduced models. Simple resistance-compliance models are preferred because the inertial effects appear to have only slight influence. In particular, the choice of a five-parameter model seems to be convenient for simulation purposes. An additional structure reduction is suggested to reach reliable results in parameter estimation problems. The resulting model is characterized by three elements: peripheral resistance, arterial compliance and venous compliance.

Blood Circulation↗

Electrical analogs for monitoring vascular properties in artificial heart studies.

The problem of choosing parametric descriptions of the systemic vascular bed suitable for monitoring beat-to-beat changes in peripheral vascular properties is considered. Three simple models with two, three, and five elements are compared, essentially exploiting the Akaike information criterion combined with reasonable requirements for estimate accuracy. Analysis of pressure data, which are either simulated by the five-element model or measured on a mock circulatory system during abrupt changes in peripheral resistance, suggests guidelines for model selection. In particular, the five-element model exhibits very close adherence to physical reality by allowing for reflection, while the classical windkessel model provides the most reproducible estimates.

Cardiovascular Physiological Phenomena↗

Tracking time-varying properties of the systemic vascular bed.

The problem of tracking changes in viscoelastic properties of the systemic arterial bed is considered and a recursive estimation procedure, belonging to the class of output-error algorithms with adjustable compensator, is developed and discussed. By means of computer simulations, suitable values are determined for the key design variable which controls the tradeoff between tracking ability and noise sensitivity of the algorithm. In this way, the algorithm allows on-line estimation of arterial compliance, peripheral resistance, and characteristic impedance on the basis of aortic pressure and flow signals. Furthermore, the results obtained from data numerically simulated, as well as measured on a mock circulatory system, demonstrate that the dominant arterial time-constant can be tracked by the algorithm using only measurements of the aortic pressure during diastole.

Algorithms↗

CADCS simulation of the closed-loop cardiovascular system.

A pulsatile simulator of the closed-loop cardiovascular system, designed to solve simulation, identification and control problems in a research and education context, is presented. Its implementation makes use of a command-driven interactive program for simulation of non-linear ordinary differential equations. The flexibility of the simulator is demonstrated by the results presented which refer to a basal steady-state circulatory condition as well as a transient induced by an abrupt change in peripheral resistance.