PubMed Health⌕ Search

Biomedical subjects

A Cedola

Publications and source records attributed to A Cedola.

12 recordsLinked to original sources

Engineering of bone using bone marrow stromal cells and a silicon-stabilized tricalcium phosphate bioceramic: evidence for a coupling between bone formation and scaffold resorption.

Resorbable porous ceramic constructs, based on silicon-stabilized tricalcium phosphate, were implanted in critical-size defects of sheep tibias, either alone or after seeding with bone marrow stromal cells (BMSC). Only BMSC-loaded ceramics displayed a progressive scaffold resorption, coincident with new bone deposition. To investigate the coupled mechanisms of bone formation and scaffold resorption, X-ray computed microtomography (muCT) with synchrotron radiation was performed on BMSC-seeded ceramic cubes. These were analyzed before and after implantation in immunodeficient mice for 2 or 6 months. With increasing implantation time, scaffold thickness significantly decreased while bone thickness increased. The muCT data evidenced that all scaffolds showed a uniform density distribution before implantation. Areas of different segregated densities were instead observed, in the same scaffolds, once seeded with cells and implanted in vivo. A detailed muX-ray diffraction analysis revealed that only in the contact areas between deposited bone and scaffold, the TCP component of the biomaterial decreased much faster than the HA component. This event did not occur at areas away from the bone surface, highlighting coupling and cell-dependency of the resorption and matrix deposition mechanisms. Moreover, in scaffolds implanted without cells, both the ceramic density and the TCP:HA ratio remained unchanged with respect to the pre-implantation analysis.

Animals↗

Wave-field formation in a hollow x-ray waveguide.

Diffraction and refraction phenomena at the entrance of a hollow x-ray waveguide with weakly absorbing dielectric cladding layers are investigated using two independent approaches: (a) analytical and (b) numerical solutions of the wave equation in the paraxial (parabolic) approximation. It is shown that the wave penetrating through the cladding material substantially modifies the wave field near the waveguide entrance. It results in a significant increase of the total energy flux inside the guiding layer and in additional spatial modulation of the electromagnetic field.

Journal Article↗

Dispersion properties of x-ray waveguides.

We study the propagation of ultrashort pulses in x-ray waveguides (WGs) by addressing the problem of the temporal dispersion. Starting from basic equations, by means of numerical calculation we demonstrate that far from the absorption edges of the WGs the cladding's material dispersion is negligible. However, close to the absorption edge significant dispersion can take place. This behavior could in principle be exploited to manipulate incoming chirped beams. Moreover, using the two coherent beams produced by the WG in the second (and higher) order of resonance suggests the use of the WC as a dispersion-free beam splitter, which can facilitate x-ray pump-probe experiments in the femtosecond temporal range without the need for external sources.

Journal Article↗

Engineered bone from bone marrow stromal cells: a structural study by an advanced x-ray microdiffraction technique.

The mechanism of mineralized matrix deposition was studied in a tissue engineering approach in which bone tissue is formed when porous ceramic constructs are loaded with bone marrow stromal cells and implanted in vivo. We investigated the local interaction between the mineral crystals of the engineered bone and the biomaterial by means of microdiffraction, using a set-up based on an x-ray waveguide. We demonstrated that the newly formed bone is well organized inside the scaffold pore, following the growth model of natural bone. Combining wide angle (WAXS) and small angle (SAXS) x-ray scattering with high spatial resolution, we were able to determine the orientation of the crystallographic c-axis inside the bone crystals, and the orientation of the mineral crystals and collagen micro-fibrils with respect to the scaffold. In this work we analysed six samples and for each of them two pores were studied in detail. Similar results were obtained in all cases but we report here only the most significant sample.

Anisotropy↗

Large-distance refocusing of a submicrometre beam from an X-ray waveguide.

Among the several available X-ray optics for synchrotron radiation producing micrometre and submicrometre beams with high intensity, the X-ray waveguide (WG) can provide the smallest hard X-ray beam in one direction. A drawback of this optics is that, owing to the divergence at the exit, a nanometre-sized spot on the sample can only be obtained if this is within a few micrometres of the WG exit. Another limitation is that in planar WGs the beam is compressed in only one direction. Here, using a dynamically bent elliptical Si/Pt mirror, the guided X-ray beam has been refocused at approximately 1 m from the waveguide exit. The large working distance between the device and the submicrometre focus leaves some space for sample environment (vacuum chamber, furnace, cryostat, magnets, high-pressure device etc.) and allows cross-coupled geometries with two WGs for efficient compression in two directions.

Equipment Design↗

X-ray micro-diffraction analysis of reconstructed bone at Zr prosthetic surface with sub-micrometre spatial resolution.

The purpose of the present investigation is to demonstrate the power of the x-ray micro-diffraction technique in biological studies. In particular the reported experiment concerns the study of the interface between a Zr prosthetic device implanted in a rat femur and the newly-formed bone, with a spatial resolution of 0.5 microm. The obtained results give interesting information on the Zr deformation and on the crystallographic phase, the grain size and the orientation of the new bone. Moreover the study reveals a marked difference in the structure of the reconstructed bone with respect to the native bone, which cannot be appreciated with other techniques.

Animals↗

Non-destructive determination of local strain with 100-nanometre spatial resolution

Structure sizes of approximately 180 nm are now standard in microelectronics, and state-of-the-art fabrication techniques can reduce these to just a few tens of nanometres. But at these length scales, the strain induced at interfaces can locally distort the crystal lattice, which may in turn affect device performance in an unpredictable way. A means of non-destructively characterizing such strain fields with high spatial resolution and sensitivity is therefore highly desirable. One approach is to use Raman spectroscopy, but this is limited by the intrinsic approximately 0.5-microm resolution limit of visible light probes. Techniques based on electron-beam diffraction can achieve the desired nanometre-scale resolution. But either they require complex sample preparation procedures (which may alter the original strain field) or they are sensitive to distortional (but not dilational) strain within only the top few tens of nanometres of the sample surface. X-rays, on the other hand, have a much greater penetration depth, but have not hitherto achieved strain analysis with sub-micrometre resolution. Here we describe a magnifying diffraction imaging procedure for X-rays which achieves a spatial resolution of 100nm in one dimension and a sensitivity of 10(-4) for relative lattice variations. We demonstrate the suitability of this procedure for strain analysis by measuring the strain depth profiles beneath oxidized lines on silicon crystals.

Journal Article↗

Submicrometre resolution phase-contrast radiography with the beam from an X-ray waveguide.

Experimental data with unprecedented submicrometre resolution obtained in a phase-contrast radiography experiment in a magnifying configuration are presented. The term 'phase contrast' here indicates that the phase retardation of coherent light in matter was utilized as the contrast mechanism. The coherent and divergent beam exiting an X-ray waveguide was used in a lensless configuration to magnify spatial variations in optical path length up to several hundred times. The defocused image of a nylon fibre was measured with a resolution of 0.14 micro m at the object. Sufficient contrast was found for exposure times of 0.1 s, i.e. in the regime for real-time studies.

Journal Article↗

Submicrometre beams from a hard X-ray waveguide at a third-generation synchrotron radiation source.

The use of an X-ray waveguide for scattering experiments at an undulator of a third-generation synchrotron radiation source is discussed. The performance with a perfect crystal monochromator, multilayer monochromator and focusing mirror is explored. A maximum flux of 8 x 109 photons s(-1) at lambda = 0.083 nm was obtained for a 0.15 (V) x 600 (H) micron(2) beam at the exit of the waveguide with a multilayer monochromator. The combination of an Si (111) monochromator and ellipsoidal mirror resulted in a flux of approximately 10(9) photons s(-1) but with a horizontal compression of the beam to approximately 30 micron. The use of the waveguide in diffraction experiments is addressed.

Journal Article↗

Synchrotron radiation microtomography of bone engineered from bone marrow stromal cells.

Osteoprogenitor cells expanded in vitro and associated with porous ceramic scaffolds have been proposed as bone substitutes. Animal models have been developed to test the efficacy of various cell populations and scaffolds in promoting bone repair. Qualitative analysis of the new bone formed within the ceramic scaffold is relatively easy by conventional histology. On the other hand, quantitative data are difficult to obtain. X-ray computed microtomography was used as a possible experimental technique to obtain quantitative data on the three-dimensional structure of newly formed bone and of remaining scaffold in implants after 8 weeks in vivo. Measurements were performed at the European Synchrotron Radiation Facility on beamline ID19 with a spatial resolution of about 5 microm. This study clearly indicates the possibility of nondestructive quantitative analysis of bone-engineered constructs. The technique appears suitable to compare different scaffolds (and possibly different cell populations) with regard to bone formation efficiency and reabsorbability of biomaterials in the immunodeficient mouse model.

Absorptiometry, Photon↗