PubMed Health⌕ Search

Biomedical subjects

A Chavan

Publications and source records attributed to A Chavan.

At least 19 recordsLinked to original sources

[Stent-graft implantation in the thoracic aorta. Results of an interdisciplinary survey in Germany].

BACKGROUND AND OBJECTIVE: Endovascular stent-graft placement is emerging as a novel therapeutic option in patients with disease of the descending thoracic aorta. Quality standards for performing stent-graft procedures as well as for pre- and postoperative patient management are lacking, so far. It was the aim of this present survey to assess the current therapeutic standard of thoracic aortic stent-graft placement in Germany. METHODS: In a nationwide survey, a total of 206 vascular surgical, radiologic, cardiologic, and cardiothoracic surgical departments were contacted. Data concerning preoperative procedure planning, logistics, practical/technical issues of stent-graft placement, and postoperative patient management were evaluated using a standardized questionnaire comprising 29 items. Data analysis was performed using univariate analysis. RESULTS: 184 (89.3 %) of the 206 departments participated in the survey. Of these, 71 centers reported intending to perform or having performed thoracic aortic stent-graft placement. The survey overall represents 2267 endovascular stent-graft procedures performed in Germany between 1997/98 and 2003. On average, 7.4 stent-graft procedures/year were performed by each center, with half the centers performing fewer than 5 procedures/year. Thoracic aortic aneurysms was the main indication for endovascular stent-graft placement, followed by aortic dissection. There were significant differences between the different medical specialties which perform stent-graft procedures with respect to indications, choice of preoperative and intraoperative imaging methods, and technical equipment. There was strong agreement between the different centers concerning the necessity of a life-long follow-up after stent-graft placement, with computed tomography being the preferred imaging technique (90 % of centers). CONCLUSION: The present survey documents an increasing use of endovascular stent-graft placement in patients with disease of the descending thoracic aorta. There were differences regarding the technical execution of this procedures between specialties with respect to indication, procedure planning, and practical-technical aspects of stent-graft placement.

Analysis of Variance↗

Chemoocclusion vs chemoperfusion for treatment of advanced hepatocellular carcinoma: a randomised trial.

AIMS: Transarterial chemoembolization (TACE) can be associated with considerable toxicity and treatment-associated mortality. Transient transarterial chemoocclusion (TACO) using degradable starch microspheres (DSM) has been proposed as a potentially safer alternative while maintaining anti-tumour efficiency. In a randomised phase II trial TACO was compared to transarterial chemoperfusion without DSM (TACP). METHODS: Seventy-four patients with advanced HCC were randomised to two treatment arms: (i) TACO (600-1200 mg DSM) and (ii) TACP. In both arms regional chemotherapy consisted of cisplatin (100 mg/m2) and doxorubicin (60 mg/m2). Both arms were corresponding in terms of age, gender, liver performance state, and tumour-stage. A maximum of six treatment cycles was applied in monthly intervals. Follow-up was performed in terms of tumour response, time to progression, survival and quality of life. RESULTS: Tumour response rates did not differ significantly between the two treatment arms, however, there was a tendency towards higher response rates in the TACO arm (TACO vs TACP): partial response: 26 vs 9%, stable disease: 41 vs 55%, progressive disease: 33 vs 36%. Time to tumour progression (32 vs 27 weeks), and overall survival (60 vs 69 weeks) were not significantly different. Grade 4 adverse events were rare in both arms and treatment-associated mortality was not observed. In addition, there was no significant difference in terms of quality of life under therapy (EORTC). CONCLUSION: TACO with DSM did not improve response or survival significantly compared to TACP in advanced non-resectable HCC.

Aged↗

Yersinia infection mimicking recurrence of gastrointestinal stromal tumor.

Gastrointestinal stromal tumors (GISTs) are the most common mesenchymal tumors of the gastrointestinal tract. So far, surgical resection has been the only curative treatment, but new options became available with the application of imatinib (Glivec) as a specific molecular inhibitor. Even after complete resection, GISTs have a high rate of recurrence and disease-linked mortality. Here we report on the case of a clinically well 57-year-old woman who presented to us 3 years after resection of a GIST of the small intestine. Abdominal ultrasound and CT scan showed intestinal wall thickening in the area of anastomosis and mesenteric lymphadenopathy, suggesting a recurrence of the primary GIST. However, serological testing was positive for yersinia antibodies. Surgical exploration revealed an asymptomatic infection with Yersinia enterocolitica serotype O9, proven by positive culture and histology, which showed no evidence of malignancy. Prognostic variables for GIST as well as diagnostic measures and limitations for yersiniosis are discussed. In the end, only surgical exploration and histological analysis could establish the final diagnosis. In conclusion, GISTs have a high likelihood of recurrence even after complete resection, but an asymptomatic infection such as yersiniosis must be considered as a differential diagnosis to GIST recurrence.

Diagnosis, Differential↗

[Intraarterial calcium stimulation (ASVS) for pancreatic insulinoma: comparison of preoperative localization procedures].

PURPOSE: Evaluation of clinical relevance of the arterial stimulation procedure with venous sampling (ASVS) in the preoperative localization of insulinoma. METHODS: Thirteen patients with endogenous hyperinsulinism underwent preoperative transabdominal ultrasound (US), helical CT (CT), MRI, endoscopic ultrasound (EUS), and angiography (DSA) in conjunction with the ASVS-test for the detection of insulinoma. The results were compared with intraoperative findings, intraoperative ultrasound (IOUS) and histology. RESULTS: Sensitivity was as follows: US 8%, MRI 27%, CT 46%, EUS 50%,DSA 69%,and ASVS 92%. Intraoperative palpation and IOUS yielded a sensitivity of 77%. In 3 patients the tumors were neither palpable nor detectable by IOUS, the mode of resection was based on preoperative diagnostics. The ASVS procedure as a functional test was superior to all other modalities for the preoperative tumor detection. CONCLUSION: The ASVS was the most sensitive diagnostic modality. It should especially be considered in terms of health economical aspects when CT or MRI do not yield conclusive results.

Adolescent↗

Ureteric reconstruction.

Although the ureter is functionally simply a tube to transport urine, ureteric surgery requires detailed anatomical knowledge and advanced surgical skills, because the ureter has a delicate blood supply. Therefore, the urological surgeon must have distinct strategies available to bridge ureteric defects of various sites and lengths. Furthermore, handling during and after surgery should be individualized to the patient's pre- and intraoperative situation. In this review, the indications for reconstruction of a specific ureteric defect, the required techniques and postoperative recommendations are discussed.

Humans↗

Use of Doppler ultrasonography to predict the outcome of therapy for renal-artery stenosis.

BACKGROUND: Prospectively identifying patients whose renal function or blood pressure will improve after the correction of renal-artery stenosis has not been possible. We evaluated whether a high level of resistance to flow in the segmental arteries of both kidneys (indicated by resistance-index values of at least 80) can be used prospectively to select appropriate patients for treatment. METHODS: We evaluated 5950 patients with hypertension for renal-artery stenosis using color Doppler ultrasonography, and we measured the resistance index ([1 - end-diastolic velocity divided by maximal systolic velocity] x 100). Among 138 patients who had unilateral or bilateral renal-artery stenosis of more than 50 percent of the luminal diameter and who underwent renal angioplasty or surgery, the procedure was technically successful in 131 (95 percent). Creatinine clearance and 24-hour ambulatory blood pressure were measured before renal-artery stenosis was corrected; 3, 6, and 12 months after the procedure; and yearly thereafter. The mean (+/-SD) duration of follow-up was 32+/-21 months. RESULTS: Among the 35 patients (27 percent) who had resistance-index values of at least 80 before revascularization, the mean arterial pressure did not decrease by 10 mm Hg or more after revascularization in 34 (97 percent). Renal function declined (defined by a decrease in the creatinine clearance; of at least 10 percent) in 28 (80 percent); 16 (46 percent) became dependent on dialysis and 10 (29 percent) died during follow-up. Among the 96 patients (73 percent) with a resistance-index value of less than 80, the mean arterial pressure decreased by at least 10 percent in all but 6 patients (6 percent) after revascularization; renal function worsened in only 3 (3 percent), all of whom became dependent on dialysis; and 3 (3 percent) died (P<0.001 for the comparison with patients with a resistance-index value of at least 80). CONCLUSIONS: A renal resistance-index value of at least 80 reliably identifies patients with renal-artery stenosis in whom angioplasty or surgery will not improve renal function, blood pressure, or kidney survival.

Angioplasty, Balloon↗

[Concepts for optimizing stent graft treatment of abdominal aortic aneurysms based on results of animal experiments].

PURPOSE: In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purposes of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. MATERIAL AND METHODS: After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi und Pavcnik developed the "Twin-tube endografts" (TTEG) and the "Bifurcated drum occluder endografts" (BDOEG) and tested them in dogs. RESULTS: Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140 +/- 46 ml/min before, 137 +/- 58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p = 0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. DISCUSSION: Supra-renal fixation of the stent-graft does not significantly affect renal function. Depending partly on the stent-graft-Design, isolated microinfarcts in the kidneys or thrombotic occlusions of the renal arteries may occur. A laparoscopic banding of the aorta at the proximal neck after graft implantation could prevent widening of the proximal neck and graft dislocation with the passage of time. To reduce the incidence of endoleaks, embolization of large branches, particularly those arising from aneurysms without mural thrombus is advisable. Due to the relatively high rate of occlusion of the graft limbs, the TTEG and the BDOEG stent-graft designs still require refinement. A rational application of the results of these animal experimental studies in clinical practice could markedly improve the long-term results of endoluminal stent grafting of abdominal aortic aneurysms.

Aortic Dissection↗

Precise determination of aortic length in patients with aortic stent grafts: in vivo evaluation of a thinning algorithm applied to CT angiography data.

The aim of this study was to develop a technique for precise determination of the aortic length using volumetric CT data for potential use prior to endovascular stent-graft placement. The study population consisted of 20 patients (38 measurements) with already performed endoluminal grafting. This allowed for in vivo evaluation of our technique. Its length according to the graft specifications served as a gold standard for our own measurements. The implemented graft length varied between 120 and 195 mm. Computed tomography angiography was performed with 3-mm slice collimation, 5-mm table feed and a reconstruction interval of 2 mm. Following semi-automatic segmentation of the aorta and its large side branches, the median centerline (skeleton) of the vessels was determined employing a modified three-dimensional thinning algorithm. The algorithm was validated by comparing the calculated length of the resulting skeleton with the specifications of the grafts. The calculated length was sufficiently precise despite the limiting reconstruction interval of 2 mm of our CT data which only permitted an assessment of stent length in 2-mm steps. The differences in the measured length and graft length were in the range between 0 and 8 mm (< 5%) with a mean fractional error of 2.46 +/- 2.37 mm. The use of an intelligent region growing algorithm capable of coping with variable arterial enhancement significantly reduced operator post-processing time. The average time necessary for segmentation was 7 min (range 3-10 min). Our algorithm provides a non-invasive method for objective and precise measurement of aortic length apparently even in tortuous vessels. It has the potential to replace angiography for aortic and iliac length measurements with calibrated catheters prior to endovascular intervention.

Algorithms↗

[Hereditary hemorrhagic telangiectasia (Osler-Rendu-Weber disease) and its manifestation in the liver].

M. Osler (Hereditary Hemorrhagic Telangiectasia, HHT) is an autosomal dominant inherited disease, with various vascular malformations. The genetic cause of this disease lies in different defects of transmembrane proteins (endoglin, activin receptor like-kinase 1) that can be defined as components of the receptor complex for transforming growth factor beta (TGF beta). Vascular malformations include the gastrointestinal tract and especially the liver. The location of mutations encoding hepatic involvement of M. Osler still remains unknown. These vascular malformations may lead to different shunts in the liver and can result to different complications like cardiac-insufficiency, portal hypertension and hepatic encephalopathy in adulthood. Color Doppler sonography is the method of choice for screening patients with M. Osler--suspected of having hepatic involvement. As in rare events conservative treatment of complications of hepatic involvement fail, embolization of the hepatic artery as minimal invasive therapy, surgical ligation of the A. hepatica and liver transplantation are possible treatment options. As there are only limited experiences with these therapeutic procedures patients with liver involvement should be treated at a center, where all therapy options are available.

Embolization, Therapeutic↗

Role of the intra-arterial calcium stimulation test in the preoperative localization of insulinomas.

The aim of this study was determination of the significance of the arterial stimulation test with venous sampling (ASVS) in the preoperative localization of insulinoma. Eleven patients with endogenous hyperinsulinism underwent preoperative transabdominal US, spiral computer tomography (spiral CT), MRI, endoscopic ultrasound (EUS) as well as angiography (DSA) combined with ASVS. The results were compared with intraoperative findings, intraoperative ultrasound (IOUS) and histopathology. There were no complications related to the ASVS test. In 11 patients the tumor could be localized with the various modalities as follows: US 1 of 11 (9%), MRI 3 of 10 (30%), spiral CT 4 of 11 (36%), EUS 5 of 10 (50%), DSA 8 of 11 (73%), and ASVS 10 of 11 (91%). In 2 patients the tumors were intraoperatively neither palpable nor detectable by IOUS, and consequently the intraoperative management was governed by information provided by DSA combined with the ASVS test. Ten patients had solitary benign insulinomas and 1 patient with multiple endocrine neoplasia I had two tumors adjacent to each other in the pancreatic tail. Arterial stimulation test with venous sampling was the most sensitive preoperative test for regionalizing the insulinoma in our set of patients. It can be performed safely in the course of a regular DSA examination and may affect intra-operative management in patients in whom the tumors are not detectable by palpation or IOUS.

Adolescent↗

Endoluminal grafting of abdominal aortic aneurysms: experience with the Talent endoluminal stent graft.

The aim of this study was to evaluate the Talent endoluminal stent graft (TESG) in treating abdominal aortic aneurysms (AAA). The TESG is a polyester-covered nitinol endograft (proximal diameters 20-38 mm and iliac limb diameters 8-22 mm). Twenty-two men were treated with the TESG via bilateral femoral arteriotomies. Pre-implantation, coil embolization of various vessels arising from the aneurysm was performed in 6 patients. Plain radiographs and spiral CT angiograms (CTA) were carried out at 7 days, 3, 6, and 12 months following TESG implantation or re-intervention. Median aortic and iliac diameters were 27 mm (range 20-34 mm) and 14 mm (range 10-19 mm). The corresponding graft diameters were 30 mm (range 24-38 mm) and 14 mm (range 12-20 mm). No patient was rejected purely on the basis of too large aortic or iliac diameters. Eight patients required custom-made grafts. Graft implantation was successful in all patients. There were no blood transfusions, distal embolic episodes, or conversions to open surgery. Re-intervention was necessary in 1 patient. Complications included one fatal myocardial infarction, one inguinal hematoma, and two superficial wound infections. The aneurysm thrombosed completely following implantation in 14 patients and at 3 or 6 months in 4 other patients. One patient with endoleak is awaiting his 3-month control and 2 patients show tiny endoleaks but reduction of aneurysm size. The mean aneurysm size decreased significantly from 58 +/- 10 to 53 +/- 13 mm (p < 0.0005). Due to the large sizes available and the option of custom-made grafts, the TESG helps widen the spectrum of patients who can be treated with endoluminal grafting. The treatment is associated with a significant reduction in aneurysm size.

Aged↗

Simultaneous treatment of thoracic and infrarenal aortic aneurysm using a combination of conventional surgery and endoluminal stent grafting.

INTRODUCTION: Patients with multiple aortic aneurysms represent a small subgroup with the need for extensive surgical treatment at considerable risk. Endovascular treatment in combination with conventional operation is possible. We demonstrate a case with simultaneous exclusion of aneurysms of the descending thoracic and the infrarenal aorta to outline the technical obligations. CONCLUSION: Simultaneous exclusion of a thoracic and an abdominal aneurysm can be performed successfully by conventional infrarenal aortic replacement with bifurcated dacron prosthesis and endovascular implantation of a thoracic stent-graft within one operation.

Anastomosis, Surgical↗

Current practice of temporary vena cava filter insertion: a multicenter registry.

PURPOSE: To evaluate the current practice of temporary vena cava filter placement and its complications. MATERIALS AND METHODS: A multicenter registry was conducted from May 1995 until May 1997 using a standardized questionnaire. One hundred eighty-eight patients were evaluated. Patient characteristics, filter indications, filter characteristics, and complications were registered. RESULTS: Deep vein thrombosis was proven in 95.2% of the patients. Main filter indication was thrombolysis therapy (53.1%). Average filter time was 5.4 days. An Antheor filter was inserted in 56.4%, a Guenther filter in 26.6%, and a Prolyser filter in 17.%. Transfemoral filter implantation was slightly preferred (54.8%). Four patients died of pulmonary embolism (PE) during filter protection. Major filter problems were filter thrombosis (16%) and filter dislocation (4.8%). When thrombus was found in or at the filter before explantation, additional thrombolysis was performed in 16.7%, additional filter implantation in 10%, and thrombus aspiration in 6.7%; 4.8% of filters were replaced with permanent filters. DISCUSSION: Temporary vena cava filters are placed to prevent PE in a defined patient population. Despite their presence, PEs still occur in a small percentage. Problems of filter thrombosis and dislocation have to be solved. CONCLUSION: The results of this multicenter registry support the need for innovative filter design, as well as a randomized, prospective study.

Adolescent↗

[Minimally invasive therapy options in aortic dissections].

Current day therapy for aortic dissection is aimed at the relief of branch vessel ischemia and the prevention of aortic rupture or aneurysm formation. Malperfusion complicating aortic dissection has historically been treated by surgery. Operations in patients with branch-vessel involvement may be technically difficult and the operative mortality is reported to be between 25% and 51%. This may rise to above 70% in patients with critical mesenteric or renal ischemia. Over the past decade, successful relief of such ischemia using the interventional radiological techniques of balloon fenestration, stent implantation and/or thrombolysis has been reported. In addition to being less invasive, this approach is associated with a lower mortality, ranging between 0% and 25%. Patency of the false lumen increases the probability of aortic rupture or aneurysm formation. Recent studies have reported successful closure of the proximal entry site with the help of stent grafts. The aim of the intervention is to initiate a thrombosis of the false lumen and thus stabilize the dissection. Based on a review of the literature and our own experience, we discuss the percutaneous management of branch vessel ischemia complicating aortic dissection as well as the role of stent graft implantation in patients with aortic dissection.

Aortic Dissection↗

Chemoembolization of hepatic metastases from intestinal neuroendocrine tumours.

Gastrointestinal neuroendocrine tumours, i.e. carcinoids and islet cell tumours, often metastasize diffusely into the liver, rendering complete surgical resection impossible. Unlike other malignancies, prolonged survival may occur even in advanced disease. Chemotherapy of these rare tumours is not only aimed at size reduction (objective response) but also at symptom reduction (biological response). Systemic therapy, using 5-fluorouracil, doxorubicin, cisplatin, cyclophosphamide, somatostatin-analogue, interferon or streptozotocin yielded response rates of up to 69%. Since neuroendocrine tumours are generally hypervascular locoregional chemotherapy and chemoembolization also have been used successfully. However, even though severe complications are rare, some degree of pain and the post-embolization syndrome are almost inevitably present. The expected therapeutic efficacy must be weighed against possible side effects. The best result that can be hoped for in the chemoembolization of intestinal neuroendocrine metastatic disease is, as yet, only palliation.

Antineoplastic Agents↗

Matched-pair analysis of conventional versus endoluminal AAA treatment outcomes during the initial phase of an aortic endografting program.

PURPOSE: To investigate whether endovascular stent-grafts implanted during the early phase of an aortic endografting program have advantages over conventional surgical procedures for treatment of infrarenal aortic aneurysm (AAA). METHODS: In the first months of an endografting program, 37 patients (36 men; mean age 67.9 +/- 7.1 years, range 55 to 86) underwent AAA repair with endovascular implantation of a Vanguard (n = 17) or Talent (n = 20) bifurcated stent-graft. Data collected during the perioperative period and in follow-up were compared retrospectively to a matched group of 37 elective surgical patients. RESULTS: All endograft implantations were completed. Two type I and 6 type II endoleaks (21.6%) were seen postoperatively. Five type II sealed without intervention; 1 type I endoleak was corrected with an additional stent, but 1 type I and 1 type II endoleaks persisted despite attempts with coil embolization. Two (5.4%) endograft patients died during the perioperative period; however, this was not significantly different (p = 0.15) from the control group. In the mean follow-up of 12 +/- 6 months for both groups, 1 (2.7%) late conversion was necessary at 2 years for aneurysm expansion in an endograft patient with an unsealed type I endoleak. CONCLUSIONS: In our learning curve experience with aortic endografting, postoperative morbidity and mortality were higher in endograft patients compared to conventionally treated controls. Only in the endograft group was reoperation required during follow-up. Careful monitoring with periodic imaging studies is mandatory after endoluminal AAA treatment.

Aged↗

Detection of significant renal artery stenosis with color Doppler sonography: combining extrarenal and intrarenal approaches to minimize technical failure.

BACKGROUND: Renal artery disease can cause both hypertension and renal failure, and color Doppler sonography (CDS) may be a good screening method to detect it. Presently reported techniques of Doppler sonography have either a high rate of technical failure (4-42%), or low sensitivity and specificity, or detect only stenoses greater than 70%, or exclude patients with renal failure from analysis. In previous studies Doppler detection of renal artery stenosis (RAS) was based either on increased intrastenotic velocity or on the detection of post-stenotic Doppler phenomena. In the present prospective study these two approaches were combined to detect RAS (> or = 50% diameter reduction) in 226 consecutive patients (144 with normal and 82 with impaired renal function). METHODS: Stenosis of 50% or more was diagnosed if the maximal systolic velocity in the main renal artery was more than 180 cm/sec and velocity in the distal renal artery less than one quarter of the maximum velocity. When these velocities could not be determined a diagnosis of RAS was made when the acceleration time in intrarenal segmental arteries exceeded 70 msec. All patients subsequently underwent arteriography as the gold standard for the detection of RAS. RESULTS: With this combined approach, the technical failure rate of CDS was 0% in both patients with normal and those with impaired renal function. The mean time required for the Doppler investigation was 17 minutes. The sensitivity and specificity for detection of a significant stenosis in a given vessel (including accessory arteries), as compared to angiography, were 96.7% and 98.0%. CONCLUSION: Color Doppler sonography, evaluating both main renal and intrarenal arteries is an ideal screening method for detection of RAS of 50% or more because it allows accurate and rapid detection of stenosis in all patients, irrespective of renal function.

Blood Flow Velocity↗

[Performance of different CT angiography imaging modalities in detecting renal artery stenoses].

PURPOSE: Purpose of the study was to compare the sensitivity and specificity of various display modalities in the detection of renal artery stenosis. In particular, the difference between hard-copy reading and interactive analysis at the workstation was assessed. MATERIALS AND METHODS: Selected patients (n = 31) with expected suboptimal conditions for CT angiography due to long-standing hypertension and compromised renal function were included. Six radiologists evaluated independently a total of 77 renal arteries with 49 renal artery stenoses proven by angiography. Image analysis included: mode A: interactive display, analysis of multiplanar reformats and axial sections at the workstation, mode B: visualization of MIPs in the coronal and axial planes as hard copies only, mode C: visualization of MIPs and axial sections as hard copies only. RESULTS: The following sensitivities and specificities were found for internal readers and (readers from outside institutions): mode A: 94.8%, 87.9%, mode B: 97.7% (95.1%), 80.3% (75.4%); mode C: 97.0% (95.3%), 78.8% (76.6%). The differences were statistically not significant (p > 0.05). CONCLUSIONS: Standardized hard copies of MIPs plus axial CT provide sufficient accuracy to detect renal artery stenosis compared to interactive imaging even in this highly selected group of patients.

Adult↗