A rotating PET scanner using BGO block detectors: design, performance and applications.

Recent advances in fully three-dimensional reconstruction for multi-ring PET scanners have led us to explore the potential of a prototype scanner based on the rotation of two opposing arrays of BGO block detectors. The prototype contains only one-third of the number of detectors in the equivalent full ring scanner, resulting in reduced cost. With a lower energy threshold at 250 keV, the absolute efficiency of the scanner is 0.5% and the scatter fraction is 35% for a 20-cm cylinder. Transaxial and axial spatial resolution is about 6 mm. The maximum noise equivalent count rate estimated for a 15-cm diameter cylinder is 36,000 cps at a concentration of 26 kBq/ml. The minimum scan time for a 18F-fluoro-2-deoxyglucose (FDG) brain study is 55 sec. The camera has been validated for clinical applications using both FDG and 82Rb.

Algorithms↗

High density avalanche chamber (HIDAC) positron camera.

A prototype positron camera has been constructed consisting of two high density avalanche chamber (HIDAC) detectors operated in coincidence with a resolving time (2 tau) of 40 nsec. The detectors are multiwire chambers, with specially constructed lead converters added to improve the photon detection efficiency at 511 keV. The current HIDAC detectors have a singles efficiency of approximately 12%, a sensitive area of 31 X 31 cm and an intrinsic spatial resolution of less than 2 mm full width at half maximum (FWHM). During data acquisition, the detectors are rotated around the patient in order to collect a complete angular data set. A three-dimensional image of the positron distribution is reconstructed from a single scan by weighted backprojection of the data into a matrix of either 64 X 64 X 64 or 128 X 128 X 16 voxels. The camera point response function is deconvolved by frequency-space filtering. Corrections are made during backprojection both for photon attenuation and for spatial variations in point source sensitivity. The reconstructed image is further corrected for contributions from accidental and scattered coincidences and displayed as a sequence of two-dimensional transverse, sagittal, or coronal sections. In addition, three-dimensional display is available using shaded graphics techniques. The prototype camera is currently undergoing clinical evaluation.

Bone Neoplasms↗

Tomographic imaging of the human thyroid using 124I.

After receiving between 100 and 300 mu Ci of the positron-emitting radioisotope 124I (half-life, 4.2 days), 64 patients with a variety of thyroid disorders were imaged with a high resolution positron camera. A 3-dimensional image of the distribution of radioiodine uptake within the thyroid was obtained from a single 10- to 15-min scan. This image may be viewed as a sequence of 2-mm thick transverse, sagittal, or frontal sections or as a 3-dimensional shaded surface. The functional volume of the thyroid may be estimated by counting the volume elements (voxels) inside the thyroid surface. The precision of the estimate varied from 6-15%, depending on the size and clinical status of the thyroid. The volume estimation procedure was validated with phantoms and with the thyroids of patients who subsequently underwent partial thyroidectomy. This 3-dimensional imaging technique may be useful for diagnosis and management of thyroid diseases.

Adenoma↗