A new chemical etching process to improve endosseous implant osseointegration: in vitro evaluation on human osteoblast-like cells.

The development of novel mechanical and chemical surface modification treatments to improve the osteointegration properties of osseointegrated dental implants is nowadays a topic of great applicative interest. The aim of the present study was to analyse the role of surface topography and chemistry of four different surface treatments on titanium by an in vitro human osteosarcoma immortalised cell line model (MG63). The surface treatments considered were (a) machined titanium, (b) chemical etched on machined titanium, (c) sandblasted titanium and (d) chemical etching on sandblasted titanium. Chemical and physical surface properties were investigated by Scanning Electron Microscopy, Thin Film-X ray Diffraction and by Laser Profilometry. The in vitro biological response was characterised using the MG63 cell line by elution cytotoxicity tests, cell morphology, adhesion, proliferation activity, alkaline phosphatase activity and total DNA content in order to show a relationship between osteoblast response and surface features. Chemical and physical characterisation showed that the considered treatments differently modify the surface morphology in the micro and sub-micrometric scale. Although some differences in alkaline phosphatase activity were observed in the biological characterisation, depending on the specific material's surface finishing, the results showed that cells were well responsive on all the tested materials and grew and differentiated with similar proliferation rate.

Air Abrasion, Dental↗

Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation.

Alloys based on Ni-Ti intermetallics generally exhibit special shape memory and pseudoelastic properties, which make them desirable for use in the dental field as orthodontic wires. The possibility of nickel release from these materials is of high concern, because the allergenicity of this element. The aim of this study was to test pseudoelastic Ni-Ti wires in simulated physiological conditions, investigating the combined effect of strain and fluoridated media: the wires were examined both under strained (5% tensile strain) and unstrained conditions, in fluoridated artificial saliva at 37 degrees C. Real time electrochemical nickel release testing was performed using a novel application of a radiotracer based method, thin layer activation (TLA). TLA was validated, in unstrained conditions, against adsorptive stripping voltammetry methodology. Control tests were also performed in non-fluoridated artificial saliva. From our research it transpired that the corrosion behaviour of Ni-Ti alloy is highly affected by the fluoride content, showing a release of 4.79+/-0.10 microg/cm2/day, but, differently from other biomaterials, it does not seem to be affected by elastic tensile strain. The application of the TLA method in the biomedical field appears a suitable technique to monitor in real time the corrosion behaviour of biomedical devices.

Biomimetic Materials↗

Materials characterization of explanted mechanical heart valves and comparison to patients' clinical data.

In the present study, twelve explanted mechanical heart valves (MHVs)with pyrolitic carbon tilting disc and 14 bileaflet MHVs were analyzed to investigate the effects of material properties on valve performance and patients' general health conditions. Optical and scanning electron microscopy was used to investigate material imperfections, wear patterns or damages to housing and occluder components. All analyzed tilting disc valves exhibited wear effects, particularly due to abrasion and impact to both disc and housing. Wear of pyrolitic carbon disc and housing did not influence their in vivo performance. In the bileaflet MHVs, breakaway of the pyrolitic carbon coating sometimes caused malfunctioning and required surgical retrieval of the valve. In all cases, occurrence of clinical symptoms was more likely when wear effects were located in critical areas. The study supports a correlation between the properties of the MHVs material and patients' symptoms.

Adult↗

Decreased bacterial adhesion to surface-treated titanium.

Osteointegrative dental implants are widely used in implantology for their well-known excellent performance once implanted in the host. Remarkable bacterial colonization along the transgingival region may result in a progressive loss of adhesion at gum-implant interface and an increase of the bone area exposed to pathogens. This phenomenon may negatively effect the osteointegration process and cause, in the most severe cases, implant failure. The presence of bacteria at implant site affect the growth of new bone tissue and consequently, the achievement of a mechanically stable bone-implant interface, key parameters for a suitable implant osteointegration. In the present work, a novel surface treatment has been developed and optimized in order to convert the amorphous titanium oxide in a crystalline layer enriched in anatase capable of providing not only antibacterial properties but also of stimulating the precipitation of apatite when placed in simulated body fluid. The collected data have shown that the tested treatment results in a crystalline anatase-type titanium oxide layer able to provide a remarkable decrease in bacterial attachment without negatively effecting cell metabolic activity. In conclusion, the surface modification treatment analyzed in the present study might be an elegant way to reduce the risk of bacterial adhesion and increase the lifetime of the transgingival component in the osteointegrated dental implant.

Animals↗

Soft tissue response to a new austenitic stainless steel with a negligible nickel content.

This study evaluates the soft tissue response to a new austenitic stainless steel with a low nickel content (P558) in comparison with a conventional stainless steel (SSt)and a titanium alloy (Ti6Al4V). Previous findings showed its in vitro biocompatibility by culturing P558 with healthy and osteoporotic osteoblasts and its in vivo effectiveness as bone implant material. Regarding its use as a material in osteosynthesis,P558 biocompatibility when implanted in soft tissues, as subcutis and muscle, was assessed. Disks and rods of these metals were implanted in rat subcutis and in rabbit muscle, respectively. Four and twelve weeks post surgery implants with surrounding tissue were retrieved for histologic and histomorphometric analysis: fibrous capsule thickness and new vessel formation were measured. Around all implanted materials, light microscopy highlighted a reactive and fibrous capsule formation coupled with ongoing neoangiogenesis both in rats and in rabbits. Histomorphometric measurements revealed a stronger inflammatory response,in terms of capsule thickness,surrounding SSt implants (9.8% Ni content) both in rat subcutis and in rabbit muscle independently of shape and site of implantation. A progressive decrease in capsule thickness around P558 (<0.02% Ni content) and Ti6Al4V, respectively, was seen. Regarding new vessel density, the data showed a different response dependent on the site of implantation. However,in the light of the previous and present studies, P558 is a good material, instead of titanium alloys, in orthopedic research.

Animals↗

A new austenitic stainless steel with a negligible amount of nickel: an in vitro study in view of its clinical application in osteoporotic bone.

A biomaterial named P558 is a new austenitic stainless steel (SS) with a negligible amount of Ni (<0.20%). In previous in vitro and in vivo studies it was compared with conventional SS and Ti6Al4V and shown to be a promising material in orthopedics. Because osteoporosis is a type of pathology very often encountered in implanted patients and can be studied with in vitro models, the purpose of the present study was to evaluate P558 in vitro through comparison of normal (nOB) with osteopenic (oOB) bone-derived primary rat osteoblasts. Osteoblasts were cultured directly on P558 and polystyrene as controls for 72 h. Osteoblast proliferation, adhesion, and activity (ALP, OC, TGF-beta1, and IL-6) were evaluated at 24 and 72 h. Results demonstrated that the growth of nOB and oOB cultured on P558 was not affected negatively when compared to control. Cells on P558 did not show any alteration in terms of adhesion, proliferation, and metabolic marker production in nOB and oOB cultures, and a significant increase in ALP, OC, and TGF-beta1 production was observed. SEM images revealed no alteration in cell morphology. The current findings demonstrate that P558 promotes osteoblast proliferation, activation, and differentiation not only in normal bone, but also in osteopenic bone-derived osteoblasts.

Biocompatible Materials↗

Histomorphometric and microhardness assessments of sheep cortical bone surrounding titanium implants with different surface treatments.

Several factors influence the healing process and the long-term mechanical stability of cementless fixed implants, such as bone remodeling and mineralization processes. Histomorphometric and bone hardness measurements were taken in implants inserted in sheep femoral cortical bone at different times to compare the in vivo osseointegration of titanium screws (diam.; 3.5 x 7 mm length) with the following surface treatments: machined (Ti-MA); acid-etched (Ti-HF); HA vacuum plasma spray (Ti-HA); and Ca-P anodization followed by a hydrothermal treatment (Ti-AM/HA). Ti-MA and Ti-AM/HA implants presented the lowest (Ra = 0.20 +/- 0.01 microm) and highest (Ra = 1.97 +/- 0.64 microm) significant (p < 0.0005) roughness value, respectively. Bone-to-implant contact of Ti-HF was lower than that of the other surface treatments at both experimental times (8 weeks: -20%, ns; 12 weeks: -30%, p < 0.01). Significant differences in MAR (mineral apposition rate) were also found between the different experimental times for Ti-MA (115%, p < 0.01) and Ti-HF (57%, p < 0.01), demonstrating that bone growth had slowed inside the screw threads of Ti-HA and Ti-AM/HA after 12 weeks. No bone microhardness changes in preexisting host bone were found, while Ti-MA showed the lowest value for the inner thread area at 8 weeks (HV(200 microm)= 49.8 +/- 3.8 HV). These findings confirm that osseointegration may be accelerated by adequate surface roughness and bioactive ceramic coating such as Ca-P anodization followed by a hydrothermal treatment, which enhance bone interlocking and mineralization.

Animals↗

A new austenitic stainless steel with negligible nickel content: an in vitro and in vivo comparative investigation.

New nickel (Ni)-reduced stainless-steel metals have recently been developed to avoid sensitivity to Ni. In the present study, an austenitic Ni-reduced SSt named P558 (P558, Böhler, Milan, Italy) was studied in vitro on primary osteoblasts and in vivo after bone implantation in the sheep tibia, and was compared to ISO 5832-9 SSt (SSt) and Ti6Al4V. Cells were cultured directly on P558 and Ti6Al4V. Cells cultured on polystyrene were used as controls. Osteoblast proliferation, viability and synthetic activity were evaluated at 72 h by assaying WST1, alkaline phosphatase activity (ALP), nitric oxide, pro-collagen I (PICP), osteocalcin (OC), transforming growth factor-beta1 (TGFbeta-1) and interleukin-6 (IL-6) after 1.25(OH)2D3 stimulation. Under general anaesthesia, four sheep were submitted for bilateral tibial implantation of P558, SSt and Ti6Al4V rods. In vitro results demonstrated that the effect of P558 on osteoblast viability, PICP, TGF beta-1, tumor necrosis factor-alpha production did not significantly differ from that exerted by Ti6Al4V and controls. Furthermore, P558 enhanced osteoblast differentiation, as confirmed by ALP and OC levels, and reduced IL-6 production. At 26 weeks, the bone-to-implant contact was higher in P558 than in SSt (28%, p<0.005) and Ti6Al4V (4%, p<0.05), and was higher in Ti6Al4V than in SSt (22%, p<0.005). The tested materials did not affect bone microhardness in pre-existing host bone as evidenced by the measurements taken at 1000 microm from the bone-biomaterial interface (F=1.89, ns). At the bone-biomaterial interface the lowest HV value was found for SSt, whereas no differences in HV were observed between materials (F=1.55, ns). The current findings demonstrate P558 biocompatibility both in vitro and in vivo, and osteointegration processes are shown to be significantly improved by P558 as compared to the other materials tested.

Alloys↗

Screening of stabilized crosslinked polyethylene using a novel wear tester.

A novel pin-on-disk type wear tester is described allowing a rapid screening of different types of polyethylene under both unidirectional and multidirectional sliding motion. The wear of four polyethylene materials sliding against a roughened CoCrMo alloy was evaluated: a non-irradiated UHMWPE, a UHMWPE irradiated with a dose of 25 kGy in air, and two types of crosslinked UHMWPE (100 kGy, air), which were subjected to a stabilization heat treatment in nitrogen at 155 degrees C for 72 hours (XLPE I) and in water at 130 degrees C for 72 hours (XLPE II), respectively.Under multidirectional sliding conditions both types of XLPE exhibited significantly less wear with respect to the 25 kGy irradiated UHMWPE and the non-irradiated UHMWPE, even under the rough counterface conditions applied. Under unidirectional sliding motion both types of XLPE exhibited the highest wear of all materials tested, because the orientation hardening effect acting under linear lubricated condition is less pronounced for crosslinked polyethylene.

Dose-Response Relationship, Radiation↗

Enhanced wear performance of highly crosslinked UHMWPE for artificial joints.

It is well known that osteolysis induced by polyethylene wear debris is the main cause of long-term failure of hip and knee prostheses. We developed a treatment of medical-grade ultra-high molecular-weight polyethylene (UHMWPE) in order to improve its tribologic properties and reduce its wear. Medical-grade UHMWPE was irradiated with a 200 kGy dose of radiation, thermally stabilized at a temperature close to the melting point, and then sterilized with ethylene oxide. The irradiation treatment was performed to crosslink the UHMWPE. The thermal stabilization treatment, contributing to the reaction between the free radicals generated by the irradiation process, was chosen to enhance crosslinking and to prevent oxidation and the shortening of chains. The non-invasive sterilization process with ethylene oxide was chosen to prevent the re-formation of free radicals. The wear performance of this material was compared to UHMWPE, untreated or treated with different sterilization techniques, using gamma and beta irradiation. Insoluble crosslinked constituents were measured with an extraction method. Wear was evaluated using a flat-on-ring wear test machine. While small differences were found among the different sterilization processes, 200 kGy-irradiated UHMWPE followed by thermal treatment and sterilization with ethylene oxide had the least wear and the greatest amount of crosslinking.

Biocompatible Materials↗

Synergistic effects of oxidative environments and mechanical stress on in vitro stability of polyetherurethanes and polycarbonateurethanes.

The in vitro structural stability of polyetherurethanes (PEUs) and polycarbonateurethanes (PCUs and PCUUs) was examined under strong oxidative conditions (0.5N HNO3, pH 0.3; and NaClO, 4% Cl2 available, pH approximately 13) and in the presence of a constant strain state. Solvent-cast dog-bone shaped specimens were strained at 100% uniaxial elongation over extension devices and completely immersed in the oxidative solutions at 50 degrees C for 15 days. Unstrained polyurethane (PU) samples were treated in the same way for comparison. The modification of the PU molecular structure was determined by DSC, GPC, ATR-FTIR, static contact angle, and surface roughness analyses. The incubation in nitric acid and sodium hypochlorite brought about a greater degradation of samples tested under the applied strain with the exception of PEU treated with nitric acid. PEU was the most affected material, showing bulk deterioration in NaClO and significant modifications in nitric acid, with the appearance of new IR bands, which were assigned to oxidation products. A higher phase separation between soft and hard domains occurred in PCUs upon incubation in nitric acid, the treatment with NaClO gave rise to new bands in the IR spectra, denoting the presence of oxidation products at the surface. The surface roughness greatly increased in strained PCUs with SEM evidence of deep cracks and holes or ragged and stretched fractures perpendicular to the direction of stress. PCUU underwent complex chemical modifications with a marked decrease of N-H and urea IR absorptions and showed a lower degradation than PEU and PCUs under mechanical constraint. From these results, sodium hypochlorite appears to be able to create an ESC-like degradation for PUs that are resistant to other aggressive chemical environments.

Microscopy, Electron, Scanning↗

In vitro and in vivo behaviour of Ca- and P-enriched anodized titanium.

The influence of different surface preparations on titanium biocompatibility and bone integration was evaluated. Commercially grade 2 titanium rods (diameter 2 mm, length: 3 mm), vacuum annealed and hydrofluoric acid etched was selected for its promising surface characteristics to achieve good direct osseointegration. Some rods were surface modified by Anodic Spark Discharge anodization and a thin layer (approximately 5 microm) of amorphous TiO2 containing Ca and P (Ti/AM) was obtained. Some of the Ti/AM specimens underwent a further hydrothermal treatment to produce a thin outermost layer (approximately 1 microm) of hydroxyapatite (Ti/AM/HA). Cytotoxicity tests (direct contact: ISO 10993-5) showed good cytocompatibility for all tested samples. Ti and tissue culture substrate + DMEM control, respectively, were associated with a significant higher proportion of attached cells than Ti/AM and Ti/AM/HA (P < 0.0005), but this was in the normal range of 10-20% of unattached cells for cytocompatible materials. Histomorphometric analysis conducted on samples inserted in the cancellous bone of distal femoral epiphysis of Sprague-Dawley rats gave the following results at 4 and 8 weeks: Affinity index (AI%) data proving the surface osteconductive properties of non-anodized acid etched Ti (AI-4 weeks: 67.1 +/- 17.0%; AI-8 weeks: 74.8 +/- 11.5%). Ti/AM samples showed the lowest values (AI-4 weeks: 45.8 +/- 15.9%; AI-8 weeks: 68.5 +/- 13.6%) while the best performances of the Ti/AM/HA samples (AI-4 weeks: 60.4 +/- 21.8%; AI-8 weeks: 79.5 + 9.37%) indicated that hydroxyapatite allowed a higher bone to implant contact respect to Ti only. Further investigations should be performed in order to better understand the mechanism of observed in vitro behaviour and to achieve information on long-term osseointegration process.

Analysis of Variance↗

Effect of different surface finishing and of hydroxyapatite coatings on passive and corrosion current of Ti6Al4V alloy in simulated physiological solution.

Direct and alternating current electrochemical tests were carried out on Ti6Al4V with different surface finishing and with hydroxyapatite (HA) coatings. Sand-blasting and rough titanium deposits obtained by vacuum plasma spraying (VPS) bring about an increase of passive and corrosion current density (c.d.) with respect to smooth Ti6Al4V, as a consequence of the augmentation of the real surface. The presence of HA deposits obtained by VPS causes an increase of passive and corrosion c.d. of the metallic substrate of about one order of magnitude and this should be taken into account in view of human body applications.

Alloys↗

Polyurethane-coated, self-expandable biliary stent: an experimental study.

RATIONALE AND OBJECTIVES: We describe a self-expanding metallic biliary Gianturco-Rösch stent coated with polymeric material. The coating was designed to prevent the growth of neoplastic and reactive tissue within the biliary ducts. METHODS: The stents were coated with a solvent-casting technique, which consists of dissolving polyurethane (polyether urethane or polycarbonate urethane) pellets in a solvent (dimethylacetamide), dipping the stent in the solution, and completely evaporating the solvent. In vitro mechanical characterization of the stent was performed to determine the adhesion of the coating to the metallic cage, the best introducer caliber for implantation of the device, and the relationship between the stent's diameter and radial stress. RESULTS: Reports in the literature on the biostability of polycarbonate urethane compared with polyether urethane prompted us to use the former material to coat the stents. The solvent technique gives a smooth internal surface of the stent wall, leaving in relief the coated structure of the stent on the external surface. The functional tests demonstrated that the coating did not compromise the original characteristics of the stent in terms of self-expandability, axial flexibility, and increased radial rigidity of the device. CONCLUSION: Functional tests verified coating stability and device handling, which are the first steps toward in vivo experimentation.

Bile Ducts↗

Physico-chemical observations on a failed Greenfield vena cava filter.

A Greenfield vena cava filter for the prevention of thromboembolism failed in vivo due to the displacement of 2 of the 6 legs and their subsequent break. The explanted stainless steel filter was analyzed with an electron microscope and energy dispersion system in order to assess the reason for the break. Fatigue and corrosion of the metal were responsible for the failure.

Corrosion↗

In vivo behavior of a high performance duplex stainless steel.

An in vivo investigation of a new high molybdenum and nitrogen duplex stainless steel (25Cr--7Ni--4Mo--0.3N) has been performed. Cylindrical pins and specially developed devices, to test in static conditions the in vivo localized corrosion resistance, made of this new duplex steel and of a common austenitic stainless steel were implanted in rabbit's femurs for 6 and 12 months. After sacrifice, SEM observations and EDS microanalyses to detect metallic ion release were carried out on the femur sections surrounding the pins. Morphologic observations with stereoscope and SEM were performed on the metallic surfaces of the special devices in order to detect the presence of localized corrosion. Both ion release and localized corrosion were observed for the specimens made of austenitic stainless steel, but not for those made of 25Cr--7Ni--4Mo--0.3N duplex stainless steel.

Animals↗

Adhesion properties of plasma sprayed hydroxylapatite coatings for orthopaedic prostheses.

Using Air Plasma Spraying (APS) and Vacuum Plasma Spraying (VPS) techniques, hydroxylapatite (HA) and mixtures of HA and titanium (Ti) were deposited on a Ti6A14V alloy (and on an AISI 316L steel) subjected to different surface treatments. The deposits were investigated for their crystallinity, thickness, and adhesion properties. Higher adhesion values were obtained with VPS rather than with APS. By utilising VPS, the deposition conditions were selected in order to achieve crystallinity values between 70 and 90%. The adhesion results depend on the crystallinity (increasing with its decrease), on the thickness (decreasing slightly with its increase) and especially on the surface finish of the metallic substrate. A porous Ti precoat was more effective than either chemical etching in HCl or sandblasting; sandblasting being the least effective. In particular, the double deposits consisting of a porous Ti precoat and a successive layer of HA proved to be most interesting for their higher adhesion properties and for their capability of providing primary stability due to the presence of the HA and secondary stability, in the case of its reabsorption, due to the porous metal.

Alloys↗

Duplex stainless steels for osteosynthesis devices.

The austenitic stainless steels used today for the manufacture of osteosynthesis devices are sensitive to crevice corrosion. In this study the corrosion properties of some duplex stainless steels were evaluated and compared to traditional austenitic stainless steels. According to our results the following ranking was established: 23Cr-4Ni less than AISI 316L less than ASTM F138 less than 22Cr-5Ni-3Mo less than 27Cr-31Ni-3.5Mo less than 25Cr-7Ni-4Mo-N. In particular the results showed that the high-performance 25Cr-7Ni-4Mo-N duplex stainless steel, with high molybdenum and nitrogen contents, can be considered not susceptible to crevice corrosion in the human body. The duplex stainless steels have also better mechanical properties at the same degree of cold working compared with austenitic stainless steels. Hence the 25Cr-7Ni-4Mo-N duplex stainless steel can be considered a convenient substitute of ASTM F138 for orthopedic and osteosynthesis devices.

Biocompatible Materials↗