The effects of exposure to moderate altitude on cardiovascular autonomic function in normal subjects.

Cardiovascular responses to altitude have been studied on well-trained young subjects, generally at high altitudes (>4000 m). Less known are the effects of exposure to lower altitudes, easily reached by the general population. The aim of the study was to evaluate the effects of exposure to a moderate altitude (2950 m) on heart rate (HR), blood pressure (BP) profile, and cardiovascular autonomic function, and their correlation with hemoglobin oxygen saturation (HbO2S), in untrained subjects of a wide age range. Twenty-seven healthy normotensive subjects (age range 6-83; 8 children, 9 adults, and 10 elderly subjects) underwent a battery of noninvasive cardiovascular reflex tests and 24-h ambulatory BP monitoring. Corrected QT interval was also calculated. HbO2S was measured with a transcutaneous oxymeter. All measurements were performed at about 200 m (s.l.) and repeated at 2950 m. 24-h HR and systolic/diastolic BP mean values increased at 2950 m in children (% change respectively: 6.4 +/- 6.4, p<0.05; 6.5 +/- 4.0/13.5 +/- 6.9, p < 0.05), adults (4.9 +/- 8.1, NS; 6.0 +/- 5.1/8.1 +/- 5.8, p < 0.05), and elderly subjects (7.2 +/- 4.8, p < 0.05; 5.1 +/- 2.3/2.8 +/- 4.1, p < 0.05 for systolic BP only). Standard deviation of BP mean values increased during night-time in the adult group (p < 0.05). All subjects scored normal cardiovascular test results and no differences were observed after exposure to 2950m, at both 1 hour and 24 hours from arrival. After exposure to altitude, HbO2S decreased significantly in the three groups, both on arrival and after 24 hours. No correlation was found between changes in HbO2S and BP/HR responses, and cardiovascular test results. In conclusion, exposure to moderate altitudes, easily and often reached by the general population, causes a small but significant increase in BP and HR in healthy untrained subjects of a wide age range (6-83 years). Some physiological factors (eg, lower environmental temperature and lifestyle modification) together with hypoxia, possibly more than altered cardiovascular reactivity, seem responsible for this cardiovascular change. In terms of end-organ damage, the clinical relevance of this increase in BP and BP variability for repeated exposure is not known.

Adult

Compression ultrasonography for diagnostic management of patients with clinically suspected deep vein thrombosis: prospective cohort study.

OBJECTIVE: To evaluate the safety of withholding anticoagulant treatment from patients with clinically suspected deep vein thrombosis but normal findings on compression ultrasonography. DESIGN: Compression ultrasonography was done with a simplified diagnostic procedure limited to the common femoral vein in the groin and the popliteal vein extending down to the trifurcation of the calf veins. Patients with normal ultrasonography findings at presentation were retested 1 week later. MAIN OUTCOME MEASURE: The incidence of venous thromboembolic complications during follow up for 6 months in patients in whom anticoagulant treatment was withheld on the basis of normal results on two ultrasonography tests 1 week apart. SETTING: University research centres in four hospitals. RESULTS: A total of 1702 patients were included in the study. Abnormal results on compression ultrasonography at presentation or at 1 week were found in 400 and 12 patients, respectively, for a prevalence of deep vein thrombosis of 24%. None of the patients were lost to follow up. Venous thromboembolic complications during the week of serial testing occurred in a single patient and in eight patients during 6 months' follow up, resulting in a cumulative rate of venous thromboembolic complications of 0.7% (95% confidence interval 0.3% to 1.2%). The mean number of extra hospital visits and additional tests required per initially referred patient was 0.8. CONCLUSION: It is safe to withhold anticoagulant treatment from patients with clinically suspected deep vein thrombosis who have a normal result on compression ultrasonography at the time of presentation and at 1 week.

Adolescent

A simple clinical model for the diagnosis of deep-vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process.

OBJECTIVES: We recently demonstrated the utility of a clinical model combined with ultrasonography to assist the diagnostic approach in patients with suspected deep-vein thrombosis (DVT). In this study we also sought to demonstrate that the model is useful with impedance plethysmography, a less accurate and less utilized diagnostic test. The original clinical model is slightly cumbersome to use; thus at the completion of the study we attempted to develop a simpler scoring system with a goal of maintaining accuracy. DESIGN: An open, nonrandomized, multicentre trial. SETTING: Three centres, two in Canada, and one in Italy. SUBJECTS: Ambulatory patients with suspected deep-vein thrombosis. INTERVENTIONS: All patients were assessed clinically to determine the probability for deep-vein thrombosis prior to performing impedance plethysmography and venography. We compared the accuracy of impedance plethysmography between the three pretest probability categories of high, moderate and low. All of the above were performed and interpreted by independent observers. When the study was completed, we revised the clinical model by first performing a simple regression analysis then a multiple logistic regression analysis; a scoring system was devised using the latter. RESULTS: Impedance plethysmography is significantly more sensitive and less specific for all DVT in patients with high pretest probability for deep-vein thrombosis (P = 0.001). The post- test probability (positive predictive value) for deep-vein thrombosis with an abnormal impedance plethysmography result was significantly different (P = 0.0001) between the three pretest probability categories. Multiple regression analysis has provided a new model with only nine variables and a simple scoring system. The retrospective application of the revised clinical model, which is simpler to use, suggests it will provide similar results as the original clinical model when combined with impedance plethysmography. The combination of impedance plethysmography and the clinical model suggests patients are likely to have false positive results if they have a low or moderate pretest probability for deep-vein thrombosis and false negative results if the pretest probability is high. The combination of a low pretest probability and a normal impedance plethysmography result may exclude the need for serial testing, and represented more than 50% of our patient population. CONCLUSIONS: The use of the clinical model in conjunction with impedance plethysmography would decrease the number of false positive and negative diagnoses and could markedly decrease the need for serial impedance plethysmography. Combining the clinical model with impedance plethysmography could overcome the fact that impedance plethysmography is clearly less accurate than venous ultrasound imaging. The use of the revised clinical model may increase acceptability and utility, but prospective testing is required before widespread use.

Diagnosis, Differential

A comparison of compression ultrasound with color Doppler ultrasound for the diagnosis of symptomless postoperative deep vein thrombosis.

BACKGROUND: Despite advances in primary prophylaxis, venous thromboembolism still occurs in a considerable number of high-risk surgical patients. Screening with conventional ultrasound imaging to detect asymptomatic deep vein thrombosis (DVT) has been suggested as a strategy to improve management of such patients, but it is insufficiently sensitive. We evaluated the ability of color Doppler ultrasound to improve the sensitivity of compression ultrasound in the detection of asymptomatic DVT in high-risk orthopedic patients. METHODS: We prospectively evaluated bilateral compression and color Doppler ultrasound measurements of the entire leg in 204 consecutive patients who underwent elective hip or knee replacement surgery, using contrast venography as the reference test. The sensitivity, specificity, and positive predictive value of the ultrasonography tests were determined. RESULTS: The sensitivity, specificity, and positive predictive value (with 95% confidence intervals [CIs]) of compression ultrasound for the detection of proximal DVT were 60% (39%-81%), 96% (92%-99%), and 71% (48%-89%) respectively. The sensitivity, specificity, and positive predictive value (with 95% CIs) of compression ultrasound for the detection of calf vein thrombosis were 33% (18%-52%), 91% (83%-96%), and 58% (34%-80%), respectively. Color Doppler ultrasonography did not identify any additional proximal or calf vein thrombi to those detected by compression ultrasound alone. The sensitivity for all thrombi was 47% (95% CI, 34%-61%) with a positive predictive value of 65% (95% CI, 48%-79%). CONCLUSIONS: Color Doppler ultrasonography has a moderate to low accuracy for the detection of DVT in patients who have had hip and knee replacement surgery. Color Doppler ultrasonography does not increase the detection rate for asymptomatic DVT over compression ultrasound and thus cannot be recommended as a screening test in this setting.

Hip Prosthesis

Upper-extremity deep vein thrombosis. Risk factors, diagnosis, and complications.

BACKGROUND: Little is known about the clinical, diagnostic, and prognostic aspects of upper-extremity deep vein thrombosis (UEDVT). OBJECTIVES: To identify the clinical and laboratory parameters associated with this disease, to assess the diagnostic accuracy of ultrasonographic methods for its detection, and to establish the frequency of both early and late complications. PATIENTS AND METHODS: After a careful history was taken, 58 consecutive patients with signs and symptoms that were clinically suggestive of UEDVT underwent the determination of antithrombin III and protein C and S levels and resistance to activated protein C and lupuslike anticoagulants. Compression ultrasonography, color flow Doppler imaging, and Doppler ultrasonography were performed prior to venography. Patients with confirmed UEDVT underwent objective tests to detect a pulmonary embolism and were followed up prospectively to record recurrent thromboembolic events and postthrombotic sequelae. RESULTS: Findings from venography confirmed UEDVT in 27 patients (47%). Central venous catheters, thrombophilic states, and a previous leg vein thrombosis were statistically significantly associated with UEDVT. Sensitivity and specificity of compression ultrasonography (96% and 93.5%, respectively) and color flow Doppler imaging (100% and 93%, respectively) were comparable and better than those of Doppler ultrasonography (81% and 77%, respectively). Objective findings suggestive of a pulmonary embolism were recorded in 36% of the patients with UEDVT. After a mean follow-up of 2 years, 2 patients with UEDVT experienced recurrent thromboembolic events, and 4 had postthrombotic sequelae. CONCLUSIONS: Symptomatic UEDVT is associated with central venous catheters, thrombophilic states, and a previous leg vein thrombosis. Both compression ultrasonography and color flow Doppler imaging are accurate methods for its detection. A pulmonary embolism is a common complication of the disease. Finally, this disorder may recur and may be followed by postthrombotic sequelae.

Adult

Respiratory function at different altitudes.

For the evaluation of a respiratory test at high altitude, several factors must be taken into account: the decreased barometric pressure, the decreased density of air and the degree of acclimatization which is related to the altitude and to the length of exposure. Several studies have shown a reduction in forced vital capacity (FVC) at high altitude and using simulated conditions, mainly related to an increase in pulmonary blood volume and development of interstitial edema. To assess the daily spirometric patterns during ascending to high altitudes we studied 17 healthy subjects at both Capanna Regina Margherita on the Italian Alps (4,559 m) and the Pyramid Laboratory in Nepal (5,050 m). Respiratory function tests were performed every day. Peak expiratory flow values significantly increased. The mean percent increase was 15% at 3,200 and 3,600 m and 26% at 4,559 m. FVC and MEF25 values showed a significant decrease (p < 0.005) during the first days above 3,500 m and improved only after several days spent above this altitude. For each subject the maximal reductions in FVC and maximal expiratory flow (MEF) at 25% of FVC however were found on different days. In our opinion, these data support the hypothesis that at high altitude the respiratory function can be affected by the presence of an increased pulmonary blood volume and/or the development of interstitial edema. The observed changes in forced expiration curves at high altitude seem to reflect the degree of acclimatization that is related to the individual susceptibility, to the altitude reached and to the duration of the exposure. These changes are transient and resolve after returning to sea level.

Adult

Bronchial asthma and airway hyperresponsiveness at high altitude.

The mountain climate can modify respiratory function and bronchial responsiveness of asthmatic subjects. Hypoxia, hyperventilation of cold and dry air and physical exertion may worsen asthma or enhance bronchial hyperresponsiveness while a reduction in pollen and pollution may play an important role in reducing bronchial inflammation. At moderate altitude (1,500-2,500 m), the main effect is the absence of allergen and pollutants. We studied bronchial hyperresponsiveness to both hyposmolar aerosol and methacholine at sea level (SL) and at high altitude (HA; 5,050 m) in 11 adult subjects (23-48 years old, 8 atopic, 3 nonatopic) affected by mild asthma. Basal FEV1 at SL and HA were not different (p = 0.09), whereas the decrease in FEV1 induced by the challenge was significantly higher at SL than at HA. (1) Hyposmolar aerosol: at SL the mean FEV1 decreased by 28% from 4.32 to 3.11 liters; at 5,050 m by 7.2% from 4.41 to 4.1 liters (p < 0.001). (2) Methacholine challenge: at SL PD20-FEV1 was 700 micrograms and at HA > 1,600 micrograms (p < 0.005). In 3 asthmatic and 5 nonasthmatic subjects plasma levels of cortisol were also measured. The mean value at SL was 265 nmol and 601 nmol at HA (p < 0.005). We suppose that the reduction in bronchial response might be mainly related to the protective role carried out by the higher levels of cortisol and, as already known, catecholamines.

Adult

The long-term clinical course of acute deep venous thrombosis.

BACKGROUND: In patients who have symptomatic deep venous thrombosis, the long-term risk for recurrent venous thromboembolism and the incidence and severity of post-thrombotic sequelae have not been well documented. OBJECTIVE: To determine the clinical course of patients during the 8 years after their first episode of symptomatic deep venous thrombosis. DESIGN: Prospective cohort study. SETTING: University outpatient thrombosis clinic. PATIENTS: 355 consecutive patients with a first episode of symptomatic deep venous thrombosis. MEASUREMENTS: Recurrent venous thromboembolism, the post-thrombotic syndrome, and death. Potential risk factors for these outcomes were also evaluated. RESULTS: The cumulative incidence of recurrent venous thromboembolism was 17.5% after 2 years of follow-up (95% CI, 13.6% to 22.2%), 24.6% after 5 years (CI, 19.6% to 29.7%), and 30.3% after 8 years (CI, 23.6% to 37.0%). The presence of cancer and of impaired coagulation inhibition increased the risk for recurrent venous thromboembolism (hazard ratios, 1.72 [CI, 1.31 to 2.25] and 1.44 [CI, 1.02 to 2.01], respectively). In contrast, surgery and recent trauma or fracture were associated with a decreased risk for recurrent venous thromboembolism (hazard ratios, 0.36 [CI, 0.21 to 0.62] and 0.51 [CI, 0.32 to 0.87], respectively). The cumulative incidence of the post-thrombotic syndrome was 22.8% after 2 years (CI, 18.0% to 27.5%), 28.0% after 5 years (CI, 22.7% to 33.3%), and 29.1% after 8 years (CI, 23.4% to 34.7%). The development of ipsilateral recurrent deep venous thrombosis was strongly associated with the risk for the post-thrombotic syndrome (hazard ratio, 6.4; CI, 3.1 to 13.3). Survival after 8 years was 70.2% (CI, 64.7% to 75.6%). The presence of cancer increased the risk for death (hazard ratio, 8.1; CI, 3.6 to 18.1). CONCLUSION: Patients with symptomatic deep venous thrombosis, especially those without transient risk factors for deep venous thrombosis, have a high risk for recurrent venous thromboembolism that persists for many years. The post-thrombotic syndrome occurs in almost one third of these patients and is strongly related to ipsilateral recurrent deep venous thrombosis. These findings challenge the widely adopted use of short-course anticoagulation therapy in patients with symptomatic deep venous thrombosis.

Adult

Efficacy of topical tuaminoheptane combined with N-acetyl-cysteine in reducing nasal resistance. A double-blind rhinomanometric study versus xylometazoline and placebo.

The aim of this study was to functionally evaluate the decongestant effect of a topical intranasal drug (Rhinofluimucil consisting of tuaminoheptane sulphate (CAS 6411-75-2, THS), a vasoconstrictor, combined with N-acetyl-cysteine (CAS 616-91-1, NAC). This was a double-blind randomized study, versus both xylometazoline and placebo. 18 subjects (8M and 10F, aged 20-47 years), unaffected by any rhinitic pathology, underwent anterior rhinomanometry. Following the basal evaluation (T0), subjects were randomly divided into three groups and subjected, in a double-blind manner, to nasal instillations (2 puffs per nostril) of THS/NAC (R), xylometazoline (O) and saline solution (P), respectively. Rhinomanometry was repeated after 5, 10 and 20 min (T5, T10, T20). Resistance and flow were measured in both nostrils at a pressure gradient of 150 Pa. After R and O nasal resistance significantly decreased from 0.30 Pa to 0.19 Pa and from 0.31 Pa to 0.17 Pa, respectively, and flow significantly increased; no effects were observed with placebo. In this study, THS/NAC showed rapid decongestant properties, with a significant decrease of resistance and increase of inspiratory flow. The same finding was observed with xylometazoline, but not with the placebo. The decongestant effect was rapid: it could already be observed at T5, and remained constant up to T20 without any rebound effect.

Acetylcysteine

Accuracy of clinical assessment of deep-vein thrombosis.

The clinical diagnosis of deep-vein thrombosis is generally thought to be unreliable. From experience, we hypothesised that this widely held view might be incorrect. We developed a clinical model and prospectively tested its ability in three tertiary care centres to stratify symptomatic outpatients with suspected deep-vein thrombosis into groups with high, moderate, or low probability groups of deep-vein thrombosis. We evaluated our clinical model in combination with venous ultrasonography to determine the potential for an improved and simplified diagnostic approach in patients with suspected deep-vein thrombosis. All patients were clinically assessed to determine the probability for deep-vein thrombosis before they had ultrasonography and venography. All tests were performed and interpreted by independent observers. In 529 patients, the clinical model predicted prevalence of deep-vein thrombosis in the three categories: 85% in the high pretest probability category, 33% in the moderate, and 5% in the low category. There was no statistical difference in the performance of the model in the three centres. The model demonstrated excellent interobserver reliability (Kappa = 0.85). There were important differences with ultrasonography between the high and low pretest probability groups for both positive predictive values (100% (95% CI, 94-100%) vs (63% [35-85%], respectively). Thus, use of the clinical model combined with ultrasonography would decrease the number of false positive and negative diagnosis if venography were done when the ultrasound result and pretest probability were discordant. The diagnostic process could be simplified by excluding those patients with low pretest probability and normal ultrasound results from serial testing.

Decision Trees

Heterozygous factor VII deficiency and severe hemophilia A in the same kindred.

The association between heterozygous factor VII deficiency and severe hemophilia A in the same family is described. The 18-year-old proposita had a negative personal history for bleeding events and underwent clotting evaluation after a fortuitous finding of a prolonged PT. Decreased levels of both factor VII activity and antigen to about 50% of normal, compatible with heterozygous deficiency, were found in her and in three other asymptomatic siblings. Two uncles on the paternal side had severe hemophilia A and also showed low factor VII levels. However, in these two patients factor VII deficiency was secondary to chronic liver disease due to hepatitis B and C virus infections. Combined clotting defects in the same kindred may be due to an independent segregation of two separate defects or to common gene(s) malfunction. Factor VII deficiency is frequent and probably underestimated in the general population. For these reasons factor VII deficiency can easily segregate with other clotting defects.

Adolescent

Effects of exposure to high altitude on plasma endothelin-1 levels in normal subjects.

OBJECTIVE: To assess whether the hypoxia associated with exposure to high altitude affects plasma endothelin-1 levels, and whether changes in endothelin-1 are related to those in systemic and pulmonary blood pressure. DESIGN: Eight normal subjects ascended Mount Everest to an altitude of 5050 m within a period of 8 days (study 1) and 10 ascended Mount Rosa in the Italian Alps to an altitude of 4559 m within 2 days (study 2). In study 1 systemic blood pressure, heart rate, haematocrit, haemoglobin oxygen saturation (evaluated by percutaneous oximetry) and venous plasma endothelin-1 were measured several times during the ascent, and twice more during the time spent at high altitude. In study 2 the same parameters as well as systolic pulmonary pressure by echocardiography were evaluated on the second day of resting at 4559 m. In both studies, data obtained during the expeditions were compared with those collected from the same subjects at sea level. RESULTS: In study 1 plasma endothelin-1 increased progressively up to 4240 m (from 1.8 +/- 0.1 pg/ml at sea level to 2.7 +/- 0.2 pg/ml) and decreased slightly thereafter; these increments were directly related to the decrements in percutaneous oxygen saturation, which, at that altitude, fell from 98.6 +/- 0.2% at sea level to 80.8 +/- 0.4%. Blood pressure and haematocrit also rose in response to exposure to high altitude but these changes were not related to changes in endothelin-1. In study 2 the increments in plasma endothelin-1 were similar to those observed in study 1 and the changes again correlated with changes in oxygen saturation as well as with those in systolic pulmonary pressure. On average, systolic pulmonary pressure increased from 19 +/- 1 to 26 +/- 1.9 mmHg, whereas systemic blood pressure and haematocrit were unchanged. CONCLUSION: Exposure to high altitude is associated with consistent increases in plasma endothelin-1. This is probably the result of augmented secretion of the peptide in response to hypoxia and may contribute to the physiological adaptation of the pulmonary circulation to this condition.

Adult

High altitude exposure reduces bronchial responsiveness to hypo-osmolar aerosol in lowland asthmatics.

It is well-known that many patients with asthma undergo clinical improvement during a stay at high altitude. At high altitude, the atmospheric and climatic conditions (such as hypoxia, cold and dry air inhalation) could modify the bronchial responsiveness in asthmatics. Our study was designed to assess the difference in bronchial responsiveness to hypotonic aerosol between sea level and high altitudes in nonresident asthmatic subjects. The results were obtained during two mountaineering expeditions above 4,000 m i.e. at 4,559 m on Mt Rosa, Italy; and at 5,050 m near the Mt Everest base camp in Nepal. Eleven mild asthmatics performed standard bronchial challenges with ultrasonically nebulized distilled water (5 min inhalation, delivery 2 mL-min-1) at sea level and after staying at least 72 h at the above mentioned altitudes. The decrease in forced expiratory volume in one second (FEV1) from baseline was used as index of bronchial response. There was no significant difference in pre-challenge FEV1 between sea level and high altitude in either study. However, the bronchoconstriction response to ultrasonically nebulized distilled water was significantly reduced at high altitude in both studies. At sea level the mean FEV1 decrease was 22.2% (range 15-35%), whereas as the maximal altitude it was 6.7% (range 2-11%). Our results indicate that there is a reduction in bronchial responsiveness to hypoosmolar aerosol at high altitude. This suggests that atmospheric and climatic conditions, or physiological adaptations, via mediators such as atrial natriuretic peptide, are beneficial to patients with asthma at high altitude.

Adult

The utility of non-invasive tests for detection of previous proximal-vein thrombosis.

BACKGROUND: Despite the availability of several diagnostic methods for the detection of deep-vein thrombosis (DVT), the identification of previous episodes of DVT remains a diagnostic challenge. STUDY OBJECTIVE: To assess the reliability of a combination of a standardized clinical score with three non-invasive tests: compression ultrasonography (CUS), Doppler ultrasound (DUS), and photoplethysmography (PPG), in determining the presence or the absence of previous proximal DVT. METHODS: One hundred consecutive unselected outpatients were identified, who had undergone contrast venography six to nine years previously because of the clinical suspicion of DVT (confirmed in 43). They were blindly reinvestigated by a panel of trained operators unaware of venography results. They underwent a clinical evaluation of the lower limb, by applying a standardized score to five symptoms and six signs (grading each item from 0 to 3); a PPG test to determine the venous refilling time; a DUS test to determine the venous reflux separately in the common femoral and the popliteal vein; and a CUS test to determine vein compressibility in the same regions. RESULTS: An abnormal CUS test and/or the demonstration of venous reflux in the popliteal region and/or a high clinical score (> or = 8) identified twenty-four of the 43 (56%) DVT + patients with a specificity of 89%. The combination of normal CUS with the absence of venous reflux in both the common femoral and popliteal vein and a low clinical score excluded previous thrombosis in 45 (79%) of the 57 DVT-patients (negative predictive value, 78%). Abnormal venous reflux in the isolated common femoral vein did not reliably predict the presence or absence of previous DVT. However, this occurred in only 13 (13%) patients. The PPG determination of venous refilling time did not improve the results obtained with the other tests. CONCLUSIONS: The combination of a standardized clinical evaluation with the results of CUS and DUS can reliably diagnose or exclude previous proximal-vein thrombosis in almost 90% of patients with previous episodes of suspected DVT.

Double-Blind Method

Comparison of the accuracy of impedance plethysmography and compression ultrasonography in outpatients with clinically suspected deep vein thrombosis. A two centre paired-design prospective trial.

Impedance plethysmography (IPG) and compression ultrasonography (CUS) have been reported to be highly accurate for the diagnosis of deep vein thrombosis (DVT) in symptomatic patients. In many centres CUS has become the method of choice. However, direct comparisons of the accuracy of IPG to CUS have not been performed. To determine the test of choice we performed a two centre prospective comparison of IPG and CUS, with venography, and determined how the size and distribution of thrombi influenced the accuracy of each test. 495 symptomatic outpatients with suspected DVT had evaluable venograms. The prevalence of DVT was 27% (130/495), 84% (109) of which were proximal. The sensitivity of IPG and CUS for proximal vein thrombosis was 77% and 90% respectively (p = .002). The specificity of IPG was 93% whereas the specificity of CUS was 98% (p = 0.04). There were significant differences in accuracy between the two centres as a consequence of differences in the size and location of thrombi The majority of proximal thrombi not detected by IPG and CUS involved less than 5 cm of the distal half of the popliteal vein and most of these thrombi occurred in one centre. Exclusion of these thrombi from the analysis increases the sensitivity of CUS to 99% (86/87) and IPG to 91% (72/79), for proximal thrombi (P = .019). The positive predictive value of CUS was strongly influenced by the number of abnormal venous segments (three sites were examined); 100% (80/80) if two or three sites were abnormal, but only 68% if a single site was involved. We conclude that: 1) CUS is more accurate than the IPG for the diagnosis of DVT in symptomatic outpatients, and this relationship holds true regardless of the size or location of the DVT, 2) the sensitivities of IPG and CUS are much lower for small proximal DVT, and 3) confirmatory venography is warranted if the abnormality with CUS is limited to one venous segment.

Ambulatory Care

Acquired risk factors for deep-vein thrombosis in symptomatic outpatients.

BACKGROUND: Epidemiologic studies on deep-vein thrombosis (DVT) have been mainly confined to the inpatient population. The aim of this study was to investigate the association between DVT and acquired risk factors in a large cohort of outpatients with clinically suspected DVT. METHODS: Consecutive outpatients with clinically suspected DVT were enrolled in the study. Before objective testing, all patients were interviewed by a trained physician for the presence of risk factors for DVT development. Subsequently, the presence or absence of DVT was assessed with venography. RESULTS: Approximately 50% of cases of DVT were considered to be secondary to a major risk factor (immobilization, trauma, and/or recent surgery). Among additional risk factors, only increased age (over 60 years), male gender, malignant neoplasm, heart failure, systemic lupus erythematosus, and arteriopathy were independently associated with the risk of acute DVT. CONCLUSION: Major risk factors for venous thromboembolism are a common cause of DVT among symptomatic outpatients; therefore, the usefulness of extending DVT prophylaxis in the outpatient setting should be tested. The role of additional risk factors in the development of DVT needs to be established by properly designed studies.

Ambulatory Care

Changing features of proximal vein thrombosis over time.

Recently, the sensitivity of impedance plethysmography (IPG) for the diagnosis of acute deep-vein thrombosis (DVT) in symptomatic outpatients has been questioned. In order to verify whether a change in the venographic pattern of DVT has occurred over years, accounting for the decreased sensitivity of IPG, the authors compared two series of consecutive venograms demonstrating proximal DVT, performed between 1984-1988 (166 patients) and 1990-1992 (140 patients). They evaluated both the extension and the occlusiveness of deep-vein thrombi in the two series. Moreover, changes in the referral characteristics of patients were investigated. In the second series of venograms a significant decrease in thrombi extension, expressed by a lower prevalence of iliac vein thrombosis (29% versus 43%; P = 0.0074) was observed; moreover, a significant increase in the prevalence of nonocclusive thrombi (22% versus 8%; P = 0.0004) was also recorded in the second series when compared with the first. During the study period, among the referral characteristics of patients, the authors observed both a significant decrease in the prevalence of proximal DVT (from 31% to 24%; P < 0.01) and a slight and not statistically significant decrease in the median time elapsed between onset of symptoms and referral for objective testing (from eight and a half to seven days). In conclusion, proximal deep-vein thrombi are currently less extensive and occlusive than observed in the past. These results might depend on earlier referral of less symptomatic patients and might explain the recently reported decrease in IPG sensitivity for proximal DVT.

Analysis of Variance

Endothelin-releasing stimuli and calcium antagonists in normal and pathological conditions.

BACKGROUND: Endothelin-1 is a potent vasoconstrictive peptide which circulates in blood at very low concentrations. It is mostly released from endothelial cells towards the vascular smooth muscle cells. Therefore studies addressed at increasing endothelin-1 production using physical stimuli may easily fail to cause sizeable modifications in plasma endothelin levels. Upright posture and exposure to cold, the two maneuvers so far most commonly used in humans, often have inconsistent effects on plasma endothelin-1. RECENT FINDINGS: In recent studies we have found that exposure to high altitude (4500-5000 m) caused, in normal subjects, significant increases in endothelin-1 which were correlated with those of mean arterial pressure and of systolic pulmonary pressure. CONCLUSIONS: Hypobaric hypoxia appears to stimulate the secretion of endothelin-1 and this response may contribute to the adaptation by the systemic and pulmonary circulation to the stress of altitude. If this can be confirmed, calcium antagonists, which are known to antagonize endothelin-1 mediated vasoconstriction, may be used to alleviate the pulmonary hypertension that occasionally occurs under these specific circumstances.

Calcium Channel Blockers