PubMed Health⌕ Search

Biomedical subjects

A Cupido

Publications and source records attributed to A Cupido.

2 recordsLinked to original sources

Flesinoxan, a 5-HT1A receptor agonist/alpha 1-adrenoceptor antagonist, lowers intraocular pressure in NZW rabbits.

PURPOSE: alpha1-Adrenoceptor antagonists and 5-HT1A receptor agonists reduce intraocular pressure (IOP) in the rabbit. The aims of this study were firstly, to determine the IOP-lowering effects of flesinoxan and selected other hybrid 5-HT1A receptor agonists/alpha1-adrenoceptor antagonists, and secondly, to investigate the mechanism of action of the IOP response to flesinoxan. METHODS: IOP and total outflow facility were measured in rabbits after administration of hybrid drugs. Inositol phosphates accumulation assays were performed using standard methodologies. RESULTS: Topical unilateral instillation of the drugs caused dose-related reductions of IOP. Comparison of the compounds tested revealed a potency order of WB 4101 > flesinoxan > 5-methyl-urapidil > or = BMY7378 > urapidil. WB-4101 caused a small increase in total outflow facility whereas flesinoxan had no effect. Measurement of the IC50 values for inhibition of phenylephrine-stimulated inositol phosphates accumulation in rabbit iris-ciliary body revealed a potency order of WB 4101 > 5-methyl-urapidil > flesinoxan > BMY 7378 = urapidil. Topical flesinoxan was ineffective in reversing phenylephrine-induced mydriasis, yet, pretreatment with the 5-HT1A receptor antagonists MDL 73005EF and pindolol only partially blocked the hypotensive effect of topical flesinoxan. CONCLUSIONS: The present studies indicate the potent and efficacious IOP-lowering capabilities of flesinoxan and certain other ligands with affinity for 5-HT1A receptors/alpha1-adrenoceptors. The exact mechanisms by which these drugs lower IOP in the rabbit are complex but our results indicate that flesinoxan likely reduces aqueous secretion.

Adrenergic alpha-1 Receptor Antagonists↗

Column agglutination technology: the antiglobulin test.

A new system for typing and screening blood, based on the sieving effect of glass bead microparticles, has been developed. The test is performed in a microcolumn in which the red cell agglutinates are trapped in the glass bead matrix during centrifugation, and unagglutinated cells form a pellet at the bottom of the column. Anti-human globulin reagents were incorporated in the diluent and the new test system, column agglutination technology, was compared to conventional tube tests and low-ionic-strength method. Sera and plasmas (228 samples) were screened for red cell antibodies with two anti-human globulin reagents: one containing only anti-IgG and the other containing both anti-IgG and anti-C3b, -C3d. After initial testing, there was 94-percent agreement between column agglutination technology and tube tests, and after repeat testing, there was 97-percent agreement. The column agglutination technology anti-human globulin test eliminates the need to wash red cells, which decreases the overall test time. The test is easy to perform, and the results are more objective than those with tube and microplate methods.

Antibodies, Anti-Idiotypic↗