PubMed Health⌕ Search

Biomedical subjects

A D Loguercio

Publications and source records attributed to A D Loguercio.

9 recordsLinked to original sources

A 2-year evaluation of moisture on microtensile bond strength and nanoleakage.

OBJECTIVES: This study evaluated the effect of moisture on the resin-dentin mu-bond strength (BS) and silver nitrate uptake (SNU) of three adhesive systems (Single Bond, One-Step and Syntac Single Component) soon after bonding (IM) and after 2 years of water storage (2Y). METHODS: Dentin surfaces were bonded on a dry (D), moist (W) or over-wet surfaces (OW). After restorations were constructed, specimens were stored in water (37 degrees C/24h). Resin-dentin sticks were prepared (0.8mm(2)) and they were divided for immediate (IM) and 2-year storage (2Y) testing. Half of the specimens from each period of time were tested in tension at 0.5mm/min and the other half was immersed in silver nitrate and examined by SEM-EDX. The data was analyzed by three-way repeated measures ANOVA and Tukey's tests (alpha=0.05). RESULTS: The overall BS (MPa) in the IM group under W condition was higher than in D and OW groups. After 2Y, the BS in W was lower than in the IM group, however higher than in the D and OW for OS and SB. The overall silver nitrate deposition (%) in the IM group under D, W and OW were similar. In the 2Y groups, the nanoleakage was higher than IM groups, however the increase was less pronounced in the W condition. SIGNIFICANCE: Higher BS and a significantly lower nitrate uptake were observed for IM groups, for OS and SB. Under W conditions, the BS reduction over time was less pronounced and less nitrate uptake occurred.

Absorption↗

3-Year clinical evaluation of posterior packable composite resin restorations.

This study evaluated the clinical performance of four packable resin composite restorative materials in posterior teeth (Class I and II) compared with one hybrid composite after 3 years. Eighty-four restorations were placed in 16 patients. The tested materials were: (i) Solitaire + Solid Bond; (ii) ALERT + Bond-1; (iii) Surefil + Prime & Bond NT; (iv) Filtek P60 + Single Bond and (v) TPH Spectrum + Prime & Bond 2.1. All restorations were made using rubber dam isolation, and the cavity design was restricted to the elimination of carious tissue. Deeper cavities were covered with calcium hydroxide and/or glass-ionomer cement. Each adhesive system and composite resin was placed according to the manufacturer's instructions. One week later, the restorations were finished/polished and evaluated according USPHS modified criteria. Fourteen patients attended the 3-year recall and 75 restorations were evaluated at that time based on the same evaluation criteria. Friedman repeated measures analysis of variance by rank and Wilcoxon sign-ranked test for pair-wise comparison was used for data analysis (alpha = 0.05). The analysis was performed only for the baseline and for the 3-year period. Solitaire showed some fractures at marginal ridges in 25% of the cases. Solitaire and ALERT showed some concerns related to colour match (43 and 77%, respectively) and surface texture (86 and 77%, respectively). TPH Spectrum showed a great percentage of colour mismatch after 3 years, around 50%. Surefil and Filtek P60 showed an excellent clinical performance after 3 years, similar to the hybrid resin tested, TPH Spectrum. Solitaire did not fulfil the ADA acceptance criteria for restorative materials and, therefore, is not recommended for use in posterior restorations.

Acetone↗

Clinical evaluation of posterior composite restorations: 6-year results.

PURPOSE: To evaluate the wear resistance of resin restorations (Z100; Tetric; Charisma) in posterior teeth (Class I and II) after 6 years. MATERIAL AND METHODS: One operator placed 103 restorations in 13 patients. Each patient had at least three restorations with three different resin-based composites. All restorations were made using rubber dam isolation and the cavity design was restricted to the elimination of carious tissue. Deeper cavities were covered with calcium hydroxide and/or glass ionomer cement and in shallow and medium cavities only an adhesive system was used. Each composite was placed according to the manufacturer's instructions. In Class II cavities the resin placement followed the Krejci et al or Opdam et al technique, according to the cavity size. One week later, the restorations were finished/polished and stone dies were immediately built from the impressions. Eleven patients attended the 6-year recall, and 90 restorations were evaluated based on new stone dies. The 6-year stone dies were compared with the baseline ones by two examiners. The evaluation was based on the modified Mahler et al. criteria and Busato et al, using six different scores. The scores were statistically analyzed. RESULTS: A total of 87% of the restorations were analyzed after 6 years. Only 15% (6 for Tetric and 7 for Charisma) of the 90 evaluated restorations had been already replaced. No statistical difference was found in the wear rate of the composites used in this study. None of the patients complained of any symptom after the placement of the composite (baseline data) nor after 6 years.

Calcium Hydroxide↗

Biological restorations using tooth fragments.

A "biological" restoration technique using dental fragments and adhesive materials is described. These fragments were obtained from extracted human teeth which had been previously sterilized and stored in a tooth bank. The advantages are: the use of extracted teeth as restorative material, esthetics, and treatment cost. The positive sensation of having back the missing tooth was the most mentioned comment among patients. The disadvantages are: the difficulty of obtaining teeth with the needed characteristics, problems of making an indirect restoration, matching the original color, and the non-acceptance by some patients who consider it strange to have other people's teeth placed in their mouths.

Bioprosthesis↗

Clinical effectiveness of laser fluorescence, visual inspection and radiography in the detection of occlusal caries.

The aim of this in vivo study was to compare a laser fluorescence (LF) device with Ekstrand's visual scoring system and radiographic assessment for detection of occlusal caries. Thirty-eight adults aged 19-35 years participated in the study; a total of 57 third molars with macroscopically intact occlusal surfaces were selected. Two examiners assessed 110 sites by visual inspection (VI), bitewing radiography (BW) and LF. Teeth were then extracted and caries extent assessed by histology. The detection methods were compared by means of sensitivity, specificity, inter-examiner reproducibility (kappa statistics) and area under the ROC curve. VI and LF had similar (p > 0.05) and superior sensitivities than BW (p < 0.05). VI and BW showed similar specificities, which was superior to LF. The inter-examiner reproducibility was good for VI and BW and moderate for LF. The area under ROC curves showed that VI was better than LF. It was concluded that Ekstrand's visual scoring system is the most valid method for caries diagnosis. LF should be considered an adjunct to caries diagnosis.

Adult↗

[Dimensional changes of silver and gallium-based alloy].

Gallium-based dental alloys were created with the aim of solving the problem of toxicity of mercury. The material shows mechanical properties similar to those of dental amalgam, but researches point out two unfavorable characteristics: great corrosion and excessive post-setting expansion, and the latter is capable of cracking dental structures. The aim of this study was to evaluate, during 7 days, the in vitro dimensional alteration of a gallium dental alloy (Galloy, SDI, Australia), in comparison with a dental amalgam containing zinc (F400, SDI, Australia), as a function of the contact with saline solution (0.9% NaCl) during the setting period. The storage experimental conditions were: storage in dry environment, immersion in saline solution and contamination during condensation. Additionally, the effects of contamination during the trituration of dental amalgam and the effects of protecting the surface of the gallium alloy with a fluid resin were studied. Specimens were stored at 37 degrees C +/- 1 degree C, and measuring was carried out, sequentially, every 24 h during 7 days. When the gallium alloy was either contaminated or immersed, an expansion significantly greater than that observed in the other experimental conditions was noticed after 7 days. The application of a fluid resin to protect the surface of the cylinders was able to avoid the increase in expansion caused by superficial moisture. The amalgam alloy did not show significant dimensional alterations, except when it was contaminated during trituration.

Alloys↗

Re-attachment of anterior fractured teeth: fracture strength using different techniques.

Fracture of anterior teeth by trauma is a common problem in children and teenagers. Complex metal-ceramic crowns with considerable loss of remaining sound structure are no longer necessary due to adhesive techniques, such as composite restorations and re-attachment techniques. This study compared the fracture strength of sound and restored anterior teeth using a resin composite and four re-attachment techniques. A "one bottle" adhesive system (One-Step, BISCO) and a dual cure resin cement (Duo-Link, BISCO) were applied. Thirty-five sound permanent lower central incisors were fractured by an axial load applied to the buccal area and randomly divided into five groups. The teeth were restored as follows: 1) bonded only = just bonding the fragment; 2) chamfer-group = after bonding, a chamfer was prepared on the enamel at the bonding line and filled with composite; 3) overcontour group = after bonding, a thin composite overcontour was applied on the buccal surface around the fracture line; 4) internal dentinal groove = before bonding, an internal groove was made and filled with a resin composite; 5) resin composite group = after a bevel preparation on the enamel edge, the adhesive system was applied and the fractured part of the teeth rebuilt by resin composite. Restored teeth were subjected to the same loading in the same buccal area. Fracture strength after restorative procedure was expressed as a percentage of the original fracture strength and the results analyzed by Kruskal-Wallis statistical analysis. The mean percentages of fracture strength were: Group 1: 37.09%, Group 2: 60.62%, Group 3: 97.2%, Group 4: 90.54% and Group 5: 95.8%. It was concluded that the re-attachment techniques used in Groups 3 and 4, as well as the composite restored group (Group 5), were statistically similar and reached the highest fracture resistance, similar to the fracture resistance of sound teeth.

Bisphenol A-Glycidyl Methacrylate↗

One-year clinical evaluation of posterior packable resin composite restorations.

This study evaluated the clinical performance of four packable resin composite restorative materials in posterior teeth (Class I and II) compared with one hybrid composite after one year. Eighty-four restorations were placed in 16 patients. Each patient received at least five restorations. The tested materials were: (1) Solitaire + Solid Bond; (2) ALERT + Bond-1; (3) Surefil + Prime & Bond NT (4) Filtek P60 + Single Bond and; (5) TPH Spectrum + Prime & Bond 2.1. All restorations were made using rubber dam isolation, and the cavity design was restricted to the elimination of carious tissue. Deeper cavities were covered with calcium hydroxide and/or glass ionomer cement. In shallow and medium cavities, no protection was performed except for the respective adhesive system used in each group. Each adhesive system and resin composite was placed according to the manufacturer's instructions. One week later, the restorations were finished/polished and evaluated according to the USPHS modified criteria. All patients attended the one-year recall, and the 84 restorations were evaluated at that time based on the same evaluation criteria. The scores were submitted to statistical analysis (Chi-square test, p<0.05). Solitaire and TPH showed some fractures at marginal ridges. Solitaire, ALERT and TPH showed some concerns related to color match and surface texture. Surefil and Filtek P60 showed an excellent clinical performance after one year.

Composite Resins↗

Reattachment of fractured teeth: a review of literature regarding techniques and materials.

Anterior crown fractures are a common form of injury that mainly affects children and adolescents. The position of maxillary incisors and their eruptive pattern carries a significant risk for trauma. In the pre-adhesive era, fractured teeth needed to be restored either with pin-retained inlays or cast restorations that sacrificed healthy tooth structure and were a challenge for clinicians to match with adjacent teeth. The development of adhesive dentistry has allowed dentists to use the patient's own fragment to restore the fractured tooth. Since then, several successful case reports that use a variety of techniques and materials to reattach fractured teeth have been published. This article presents a comprehensive literature review on techniques and materials used to restore uncomplicated dental trauma.

Adolescent↗