A survey of wind speeds in indoor workplaces.

The applicability of the inhalable convention for sampling aerosols relies on its being a valid model for typical sampling environments. The current convention is based on measurements carried out in external wind speeds between 1 and 4 m.s-1. However these measurements show a degree of wind speed dependence, and it is uncertain at present how valid the convention is for describing human aspiration efficiency outside these wind speed limits. Following concerns that wind speeds in many indoor workplaces may be significantly below this range, measurements have been made in 55 work areas covering a wide range of workplaces. Measurements have concentrated on 'background' wind speeds where the influence of specific air movement sources is minimised. The pooled wind speed measurements show a highly skewed distribution with an arithmetic mean of approximately 0.3 m.s-1. Approximately 85% of all individual measurements were below this mean value. No obvious correlation was found between wind speed distribution parameters and industry type, room size or ventilation type. A limited number of comparisons were made between static anemometers and devices mounted on workers. It was found that modal wind speeds experience by workers were typically 0.05 m.s-1 higher than those measured using a static anemometer. These measurements agreed well with previously published data for similar workplaces as well as houses.

Air Movements↗

Measurement of short-term exposure to airborne soluble platinum in the platinum industry.

A number of cases of respiratory sensitization to soluble platinum have arisen in the U.K. over the last few years, despite measured 8 h TWA exposure levels below the current long-term exposure limit in most cases. One possible cause of sensitization may be as a result of high exposures over short periods. Short-term sampling has been hampered by inadequate sampling and analysis techniques. This investigation has used two types of personal inhalable sampler, with ICPMS analysis, to take 15 min TWA soluble platinum exposure measurements at three sites. The lower detection limit for soluble platinum salts was approximately 0.01 microgram m-3 for 15 min samples, allowing exposures two orders of magnitude below the exposure limit to be measured. It was found that the majority of short-term exposure levels were significantly below 0.006 mg m-3. No evidence was found for altered work practices during sampling, indicating that either sensitization is occurring at airborne exposure levels below the exposure limit, or there is an alternate route of exposure.

Air Pollutants, Occupational↗