PubMed Health⌕ Search

Biomedical subjects

A D Pacifico

Publications and source records attributed to A D Pacifico.

At least 37 records · Page 2Linked to original sources

Duration of asystolic reperfusion and reperfusate electrolyte composition influence postcardioplegia ventricular fibrillation.

The conditions of postcardioplegia reperfusion that influence cardiac electrophysiologic recovery have not yet been fully elucidated. Studies of postcardioplegia electrophysiologic recovery and reperfusion-induced arrhythmias, particularly reperfusion-induced ventricular fibrillation, are useful for improving our understanding of reperfusion injury since reperfusion-induced arrhythmias are sensitive indicators for reperfusion injury. The purpose of this study was to determine the effects of asystolic reperfusion and reperfusate electrolyte composition on postcardioplegia electrophysiologic recovery of the heart. The hypothesis tested is that the duration of asystolic reperfusion produced by a hyperkalemic reperfusate is a primary determinant for the return of cardiac electrical activity without reperfusion-induced ventricular fibrillation and that reperfusion with a hypocalcemic-hyperkalemic solution further reduces the prevalence of reperfusion-induced ventricular fibrillation by limiting myocyte calcium exposure during initial postischemic recovery. Fifty-six pigs were supported by cardiopulmonary bypass and subjected to identical conditions of hypothermic cardioplegic arrest. Reperfusion was initiated with unmodified pump blood, a hypocalcemic-normokalemic cardioplegic solution, a hyperkalemic-normocalcemic cardioplegic solution, or a hyperkalemic-hypocalcemic cardioplegic solution. The hyperkalemic-normocalcemic solution was administered at a dose of 500 ml/m2 or 1500 ml/m2. The hyperkalemic-hypocalcemic and hypocalcemic-normokalemic solutions were given only at a dose of 500 ml/m2. All cardioplegic reperfusion solutions were followed by infusion of unmodified pump blood for the remainder of the 15-minute period of controlled reperfusion. Reperfusion-induced ventricular fibrillation was less prevalent in the high-dose hyperkalemic solution group (4/12) than in the low-dose hyperkalemic solution (9/10) or unmodified pump blood (12/12) groups (p < 0.05). The transmyocardial lactate gradient at the time of initial postreperfusion electrical activity was positive (0.21 +/- 0.04 mmol/L) in the high-dose hyperkalemic group and negative (-0.05 +/- 0.09 mmol/L) in the low-dose hyperkalemic group (p < 0.05). Fibrillation was less prevalent in the hypocalcemic-hyperkalemic group (8/12) than in the other groups reperfused with cardioplegic solution at a dose of 500 ml/m2 (hypocalcemic-normokalemic, 10/10; hyperkalemic-normocalcemic, 9/10) or in the group reperfused with unmodified pump blood (12/12) (p < 0.05, hypocalcemic-hyperkalemic group versus other reperfusate groups). Reperfusion-induced ventricular fibrillation is an indicator of reperfusion injury, and in this study the conditions of reperfusion influenced the prevalence of reperfusion-induced ventricular fibrillation. Recovery of aerobic metabolism during hyperkalemia-induced asystolic reperfusion was associated with a lower prevalence of reperfusion-induced ventricular fibrillation. Combining hypocalcemia with hyperkalemia decreased the prevalence of reperfusion-induced ventricular fibrillation.

Animals↗

Usefulness and limitations of transesophageal echocardiography in the assessment of proximal coronary artery stenosis.

To assess the usefulness of transesophageal echocardiography in the evaluation of proximal coronary artery stenosis, 111 consecutive patients (mean age 61 years) who had intraoperative transesophageal echocardiography and coronary angiography within 1 week of surgery were studied. Transesophageal echocardiography visualized the entire length of the left main artery (0.2 to 2.2 cm, mean 0.93), 0.2 to 2.2 cm of the proximal left anterior descending artery and 0.1 to 3.4 cm of the proximal left circumflex artery in 103 patients (93%) and 0.1 to 4.6 cm of the proximal right coronary artery in 55 patients (49%). In the coronary artery segments visualized by echocardiography and compared with the corresponding angiographic segments, transesophageal echocardiography correctly identified 23 (96%) of 24 left main stenoses, 11 (78%) of 14 stenoses involving the left anterior descending artery, 6 (75%) of 8 left circumflex stenoses and all 7 stenoses (100%) of the right coronary artery. In all seven patients with ostial stenosis (left main artery in five and right coronary artery in two), the condition was correctly diagnosed by this technique. The sensitivity and specificity of transesophageal echocardiography in the overall evaluation of proximal coronary artery stenosis as customarily defined by angiography were 96% and 99% for the left main artery, 48% and 99% for the left anterior descending artery, 67% and 100% for the left circumflex artery and 37% and 100% for the right coronary artery, respectively. The distance of the stenotic lesion from the origin of the vessel by transesophageal echocardiography also correlated well with that measured by angiography (r = 0.63 to 0.99).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Variation in cryolesion penetration due to probe size and tissue thermal conductivity.

The purpose of this study is to present data comparing the penetration of cryolesions created by various sizes and shapes of cryoprobes in human cadaveric myocardium, fat, and tissue of the central fibrous body. Ten cryolesions were made for each combination of tissue and cryoprobe studied. All cryolesions enlarged most rapidly during the first minute of cryothermia (p less than 0.01). Maximal cryothermic penetration into nontrabeculated myocardium was 8.5 +/- 0.5 mm (15-mm flat probe) and 6.1 +/- 1.0 mm (5-mm small probe). Maximal cryothermic penetration into trabeculated myocardium was 9.4 +/- 1.0 mm (10-mm cone-tipped probe) and 7.4 +/- 0.5 mm (10-mm flat probe). Maximal cryothermic penetration into fat was 4.7 +/- 0.7 mm (15-mm flat probe) and 3.9 +/- 0.7 mm (5-mm flat probe). The deeper penetration of cryothermia into myocardium as compared with fat (p less than 0.05) is related to the lower thermal conductivity of fat. Maximal cryothermic penetration of the central fibrous body was similar to that of the myocardium with transmural freezing of the central fibrous body after 4.4 +/- 0.3 minutes of cryothermia. These data can be used when determining the optimal cryothermic exposure for ablation of arrhythmogenic tissue.

Arrhythmias, Cardiac↗

Can the heart be chronically paced with electrodes on the pericardial surface?

During implantable defibrillator (ICD) operations, we measured acute and chronic transpericardial bipolar pacing thresholds through standard myocardial surface electrodes sewn on the pericardium for chronic ICD QRS rate-sensing use. We compared observations in 24 patients on day 0 with chronic measurements in seven patients at 27.4 +/- 12.1 (median 31.7) months. The leads were used only for QRS rate-sensing, not for pacing, during the time between acute and chronic measurements. Acute transpericardial pacing threshold at 0.5-msec stimulus duration on day 0 was 4.5 +/- 2.19 V (standard deviation), median 3.5 V, and at median time 964 days postimplantation was 3.8 +/- 2.07 V, median 3.5 V. Mean acute pacing current threshold was 3.7 +/- 1.90 mA, n = 23, and chronic was 2.7 +/- 1.79 mA, n = 6. Acute bipolar impedance was 1,209 +/- 383 ohms, median 1,138 ohms, and chronic was 1,550 +/- 358 ohms, median 1,410 ohms, n = 7. Acute bipolar QRS amplitude was 12.3 +/- 5.93 mV, median 12.1 mV, n = 24, and chronic was 13.5 +/- 8.5 mV, median 17.2 mV, n = 7. None of the changes between the acute and chronic states was statistically significant, with the exception of bipolar impedance (P = 0.054). We concluded that: (1) transpericardial pacing threshold did not increase with time; (2) initial and chronic pacing impedances were high and current low; (3) QRS amplitudes were highly satisfactory for defibrillator rate-sensing; and (4) this approach to ICD implantation left the surgically virgin heart unscarred to make future transplantation easier, and enhanced safety when previous cardiac operations had been done.

Cardiac Pacing, Artificial↗

Quantitation of mapping uncertainty in Wolff-Parkinson-White syndrome. Implications for anatomic characterization and surgical division of accessory atrioventricular connections.

The purpose of this study was to quantitate the uncertainty inherent in the electrophysiologic mapping of ventricular preexcitation as seen in Wolff-Parkinson-White syndrome. An ink-coated needle electrode was constructed to serve as a point source of unipolar stimulation along the atrioventricular junction. Activation times for 11 ventricular mapping sites at the atrioventricular junction were measured for each stimulation point. Maps were successfully completed for 18 right free wall and 14 posterior septal stimulation points. The activation time at the mapping site closest to the stimulation point was termed the index activation time. Activation times identical to the index activation time were noted at 1.3 +/- 0.5 mapping sites for each free wall stimulation point and 1.9 +/- 0.9 mapping sites for each septal stimulation point (p < 0.05, septal versus free wall stimulation points). Activation times falling within 5 msec of the index activation time were noted at 2.4 +/- 1.0 mapping sites for each free wall stimulation point and at 3.9 +/- 1.4 mapping sites for each septal stimulation point (p < 0.05, septal versus free wall stimulation points). The uncertainty of electrophysiologic mapping can be quantitated, and this error should be considered when making inferences regarding the anatomy of accessory pathways based on electrophysiologic data. A knowledge of the uncertainty inherent in the localization of accessory atrioventricular connections by electrophysiologic mapping can be used to plan borders of surgical dissection that will account for this uncertainty at a 95% confidence level.

Animals↗

Oxyhemoglobin dissociation during hypothermic blood cardioplegia arrest.

BACKGROUND: Coronary sinus effluent contains desaturated blood during the first few seconds of hypothermic cardioplegia infusion in humans. This occurs despite the high affinity of hemoglobin for oxygen at a low temperature and alkaline pH. The present study quantitates oxyhemoglobin dissociation during hypothermic cardioplegic arrest. METHODS AND RESULTS: Three infusions of a 4 degrees C alkalotic blood cardioplegia solution were given into the cross-clamped aortic root during 1 hour of cardioplegic arrest. Paired aortic root and coronary sinus blood samples were obtained before and shortly after initiating cardiopulmonary bypass and at t = 5 seconds and 30 seconds during each cardioplegia infusion. Throughout the study, the hemoglobin saturation in the aortic root samples was 100%. The mean coronary sinus hemoglobin saturation at t = 5 seconds during hypothermic cardioplegia infusion ranged from 63.0% to 66.5% (p < 0.05 coronary sinus compared with aortic root samples). The coronary sinus hemoglobin saturation approximated the aortic root hemoglobin saturation at t = 30 seconds during hypothermic cardioplegia infusion. The mean PO2 of the aortic root samples ranged from 214 to 307 mm Hg during hypothermic cardioplegia infusion. The mean PO2 of the t = 5 seconds coronary sinus samples ranged from 31 to 39 mm Hg, whereas the mean PO2 of the t = 30 seconds coronary sinus samples ranged from 85 to 119 mm Hg during cardioplegia infusion (p < 0.05 coronary sinus compared with aortic root samples). CONCLUSIONS: Oxygen dissociates from hemoglobin contained in a hypothermic, alkalotic blood cardioplegia solution during the nonperfused phase of cardioplegic arrest. However, the only oxygen delivered to the myocardium during the infusion of a hypothermic alkalotic blood cardioplegia solution is oxygen physically dissolved in the solution.

Animals↗

Morphologic and surgical determinants of outcome events after repair of tetralogy of Fallot and pulmonary stenosis. A two-institution study.

Survival after entry and survival after repair (94%, 91%, and 91% at 1 month, 1 year, and 5 years, respectively) were similar in two institutions treating 196 consecutive patients, and there was no advantage (and a possible disadvantage) of a protocol of preliminary shunting and later repair in very young patients. Size and configuration of the right and left pulmonary arteries had no demonstrable effect on survival, prevalence of transannular patching, or postrepair right ventricular-left ventricular pressure ratio. Small size of the pulmonary "anulus" and trunk were risk factors for death, transannular patching, and high postrepair pressure ratio. High postrepair pressure ratio was a risk factor for death after repair. Very young age (less than about 3 months) was a risk factor for death after repair, particularly when other risk factors coexisted. The prevalence of transannular patching in patients with mild infundibular and pulmonary anulus and trunk hypoplasia decreased across the time of the study, without ill effect. The usefulness of measuring postrepair right ventricular-left ventricular pressure ratio is emphasized by the data.

Female↗

Usefulness of transesophageal echocardiography in assessment of aortic dissection.

BACKGROUND: The value of transesophageal echocardiography in the assessment of patients with aortic dissection was studied. METHODS AND RESULTS: Group 1 (34 patients) represented all patients studied at our institution with this technique in whom aortic dissection was proven by aortography, surgery, or autopsy. Group 2 (27 patients) represented all patients studied with this technique at our institution in whom aortic dissection was excluded by aortography. Transesophageal echocardiography made a correct diagnosis of aortic dissection in 33 of 34 patients (sensitivity, 97%; specificity, 100%). It also correctly demonstrated the type of dissection in all 29 patients with aortographic or surgical proof. On the other hand, computed tomography scanning, performed in 24 of 34 patients in group 1, made a correct diagnosis in only 67% of patients and misclassified the type of dissection in 33%. Transesophageal echocardiography correctly identified involvement of the coronary arteries by aortic dissection in six of seven patients as well as absence of both left and right coronary artery involvement in 10 patients with aortic dissection. This technique was also useful in detecting communications between the true and false lumens, presence of thrombi in the false lumen, and, in two patients, localized dissection rupture with formation of a false aneurysm. In both groups 1 and 2, transesophageal echocardiography correctly identified patients with moderate to severe aortic regurgitation. CONCLUSIONS: Transesophageal echocardiography is very useful in the assessment of aortic dissection.

Aortic Dissection↗

Transesophageal Doppler color flow mapping assessment of atrial septal defect.

Transesophageal Doppler color flow imaging was performed in 19 adult patients (mean age 35 years) with an atrial septal defect demonstrated by cardiac catheterization or at surgery, or both. The transesophageal study correctly identified and classified 19 of 19 shunts in contrast to 16 of 18 shunts identified by the transthoracic approach. The area of the atrial septal defect was calculated by assuming it to be circular and taking the maximal Doppler color flow jet width at the defect site as its diameter. The pulsed Doppler sample volume was placed parallel to the shunt flow direction at the defect site to obtain the mean velocity and flow duration. From these values, the shunt volume was calculated as a product of the defect area, mean velocity, flow duration and heart rate. The calculated shunt flow volume obtained by transesophageal study showed a good correlation with shunt flow volume (r = 0.91, p less than 0.001) and pulmonary to systemic blood flow ratio (r = 0.84, p less than 0.001) obtained at cardiac catheterization. The size of the defect by transesophageal Doppler color flow mapping correlated fairly well with the size estimated at surgery (r = 0.73, p = 0.004). It is concluded that transesophageal Doppler color flow imaging is useful in the detection and classification of atrial septal defects and in the assessment of shunt volumes.

Adult↗

Two-dimensional echocardiography and Doppler color flow mapping in the diagnosis and prognosis of ventricular septal rupture.

Doppler color flow mapping in conjunction with two-dimensional echocardiography was used to evaluate ventricular septal rupture after myocardial infarction (seven anterior and eight inferior) in 15 patients and to correlate these findings with cardiac catheterization and surgical or autopsy data. Ventricular septal rupture was diagnosed by turbulent flow traversing the ventricular septum. The direction and velocity of shunt flow was determined by color M-mode and conventional Doppler methods. In all patients, Doppler color flow mapping correctly defined the site of septal rupture, which occurred at areas of discordant septal wall motion or "hinge points" (six posterior inlet, three anterior inlet, and six apical trabecular septum). Each of three patients with moderate tricuspid regurgitation and three of four patients with right-to-left shunting during diastole died, and all had an elevated right ventricular end-diastolic pressure. Right ventricular wall motion index was significantly higher in the patients who died compared with those who survived (mean +/- SEM; 2.8 +/- 0.2 vs. 2.0 +/- 0.2, p = 0.012), but there was no difference in left ventricular wall motion index. The rupture size measured by Doppler color flow imaging (1.7 +/- 0.1 cm) correlated with the size determined during surgery or autopsy (1.8 +/- 0.2 cm, r = 0.68, p = 0.022) and the pulmonic-to-systemic shunt flow ratio by cardiac catheterization (2.4:1 +/- 0.3, r = 0.74, p = 0.004). Color-guided continuous-wave Doppler estimates of right ventricular systolic pressure (47 +/- 2 mm Hg) correlated with cardiac catheterization measurements (48 +/- 3 mm Hg, r = 0.90, p = 0.0002).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Clinical application of closed-loop postoperative autotransfusion.

A computerized system for postoperative autotransfusion with on-line feedback of left atrial pressure and other relevant variables is in routine use in the cardiac surgical intensive care unit at University Hospital, the University of Alabama at Birmingham, USA. The autotransfusion subsystem was integrated into an existing intensive care computer system that monitors and stores physiological data. The autotransfusion system decreases the need for bank blood and lessens the chance for patient exposure to complications possible with homologous blood transfusion. The fully automated system promotes greater hemodynamic stability than other techniques of postoperative autotransfusion. Closed-loop autotransfusion is less labor-intensive than manual methods and has proved to be cost-effective.

Blood Transfusion, Autologous↗

Mechanical myocardial actuation during ventricular fibrillation improves tolerance to ischemia compared with cardiopulmonary bypass.

Direct mechanical ventricular actuation (DMVA) is a unique non-blood-contacting biventricular assist device that provides circulatory support during ventricular fibrillation without demonstrating adverse effects on the myocardium. The purpose of this study was to assess the preservation of myocardial energy stores and myocardial responses to ischemia after circulatory support during ventricular fibrillation with direct mechanical ventricular actuation versus cardiopulmonary bypass. Twenty adult mongrel dogs were randomized to receive circulatory support with either cardiopulmonary bypass or direct mechanical ventricular actuation. After 4 hours of ventricular fibrillation, hearts were defibrillated and left ventricular transmural biopsies were obtained. Hearts were then excised and subjected to 90 minutes of normothermic total ischemia. Serial biopsies were obtained at 15-minute intervals to determine regional depletion of high energy phosphates. The time-to-peak ischemic contracture was recorded by using needle-tipped Millar catheters placed in the left ventricular endocardium, epicardium, septum, and right ventricle. Time-to-peak ischemic contracture of the endocardium (62.6 +/- 1.4 vs. 58.8 +/- 1.0 minutes, p less than 0.05) and septum (61.1 +/- 6.9 vs. 46.9 +/- 6.2 minutes, p less than 0.004) were significantly prolonged after direct mechanical ventricular actuation versus cardiopulmonary bypass, respectively. Similar trends were noted in the epicardium and right ventricular regions; however, these differences were not statistically significant. Left ventricular adenosine triphosphate (ATP) levels were better preserved after direct mechanical ventricular actuation (22 +/- 1.5 mumols/g dry wt) compared with cardiopulmonary bypass (17 +/- 1.9 mumols/g dry wt). The depletion of left ventricular endocardium ATP during normothermic ischemia was significantly delayed after direct mechanical ventricular actuation compared with cardiopulmonary bypass.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Triphosphate↗

Optimal temperature for preservation of donor myocardium.

The ideal method for the preservation of donor hearts for transplantation is unclear. To assess the optimal temperature for donor myocardium preservation, the recovery of isolated canine hearts (n = 20) exposed to 4 hours of either standard ice-chest hypothermia (0-4 degrees C) or constant moderate hypothermia (12 degrees C) were compared. Functional and metabolic data were acquired before hypothermia and every 30 minutes during 3 hours of reperfusion with oxygenated blood. Mean end-systolic pressure-volume slopes were 2.11 +/- 0.06 and 2.09 +/- 0.06 mm Hg/ml for ice-chest hypothermia and constant moderate hypothermia, respectively (p = NS), which were unchanged from control. All y intercepts during reperfusion were decreased compared with control (p = 0.002) without any differences between groups. End-diastolic pressures were greater than control throughout the reperfusion period for both groups (p = 0.02), but there was a difference in change of end-diastolic pressures with time between groups (p = 0.04). Dry/wet ratios were similar after preservation and reperfusion in both groups. ATP recovered to control levels during reperfusion for both groups although energy charge ratios were greater for hearts exposed to constant moderate hypothermia (p = 0.007). These data indicate that intracellular energy stores are well maintained by preservation using either technique. Changes in function appear to be related to altered compliance irrespective of preservation temperature. These data suggest that a wide range of temperatures may be acceptable for donor heart preservation.

Animals↗