Sequential pulse defibrillation in humans: orthogonal sequential pulse defibrillation with epicardial electrodes.

A newly described sequential pulse technique, using four mesh electrodes positioned to approximate a true orthogonal system around the heart, was compared with a single pulse system using two of these same electrodes, which were located in positions that would be used for an automatic implantable defibrillator. The influence of electrode size was also assessed. The minimal energy necessary for defibrillation (defibrillation threshold) was determined intraoperatively in 21 volunteer patients undergoing accessory pathway ablation of Wolff-Parkinson-White syndrome. Ventricular fibrillation was induced with alternating current. Ten seconds after fibrillation onset defibrillation shocks were begun using either the single or the sequential pulse technique with stored voltage incremented until defibrillation was accomplished (defibrillation threshold). Selection of the use of a single or sequential pulse technique for the initial attempt was randomized. Defibrillation thresholds were determined in three groups of patients: 1) those with four small mesh electrodes (6 cm2), 2) those with two small and two large (13 cm2) mesh electrodes, and 3) those with four large mesh electrodes. In all cases, the average minimal energy needed for sequential pulse defibrillation was less than that required for single pulse defibrillation in the same patients with the same electrodes (four small, 24.8 +/- 24.7 J single versus 6.7 +/- 8.3 J sequential; two small plus two large, 11.4 +/- 15.0 J single versus 2.7 +/- 1.4 J sequential; four large, 8.1 +/- 5.3 J single versus 3.9 +/- 2.6 J sequential). Using the 6 cm2 electrodes for single pulse defibrillation energies delivered at greater than 45 J in two patients failed to defibrillate the heart.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Surgical approach to anterior septal accessory pathways in 20 patients with the Wolff-Parkinson-White syndrome.

Right anterior septal accessory pathways in the Wolff-Parkinson-White syndrome are generally defined by electrophysiological criteria, the most important being that earliest retrograde atrial activation during AV reciprocating tachycardia occurs at the anterior medial segment of the tricuspid annulus (His bundle catheter). The purpose of our study is to describe intraoperative mapping in 20 patients with anterior septal accessory pathways, and to assess if intraoperative mapping contributes to the operative approach. At surgery, all patients had identical early ventricular activation during pre-excitation at the infundibulum. However, two groups could be identified on the basis of retrograde atrial epicardial activation during AV reciprocating tachycardia or right ventricular pacing. Group 1 comprised 16 patients with earliest activation at the interatrial septum adjacent to the His bundle. Epicardial dissection failed to affect accessory pathway conduction. The accessory pathway was only ablated when a discrete endocardial approach to the atrial septum was used. Group 2 comprised 4 patients with early atrial activation "paraseptally" in the right coronary fossa. These accessory pathways were ablated by an epicardial approach without using cardiopulmonary bypass. We conclude that right anterior septal accessory pathways as defined by electrophysiological criteria can be divided into two groups on the basis of the atrial activation sequence: (1) right septal accessory pathways in the septal para-Hissian region and (2) right anterior 'paraseptal' accessory pathways. This classification is of practical importance because the latter can be ablated using an epicardial approach without the need for cardiopulmonary bypass or atriotomy.

Adolescent↗

"Atypical" posteroseptal accessory pathway in Wolff-Parkinson-White syndrome.

The posteroseptal accessory pathway in the Wolff-Parkinson-White syndrome is associated with a delta wave that is negative in the inferior electrocardiographic (ECG) leads and the occurrence of the earliest retrograde atrial activation near the orifice of the coronary sinus during atrioventricular (AV) reentrant tachycardia. Seventy-two patients with a posteroseptal accessory pathway underwent epicardial mapping before operative ablation. The earliest epicardial activation occurred at the posterosuperior process of the left ventricle in all patients. Dissection of the posteroseptal region (right atrial-left ventricular sulcus) resulted in permanent loss of preexcitation in 69 patients and failure to abolish preexcitation permanently in 3. At reoperation in two patients, preexcitation was abolished by discrete cryoablation of the left side of the interatrial septum near the AV node approached through the atrial septum in the normothermic beating heart. At reoperation, one patient had extensive AV node dissection. All patients have had permanent loss of preexcitation. The vast majority of posteroseptal accessory pathways ("typical") are epicardial and ablated by dissection of the posteroseptal region. Rarely, posteroseptal accessory pathways are "atypical" in that they are intraseptally located near the AV node on the left atrial endocardial surface.

Adult↗

"Nodoventricular" accessory pathway: evidence for a distinct accessory atrioventricular pathway with atrioventricular node-like properties.

Two patients are described with recurrent pre-excited tachycardia and electrophysiologic characteristics typically ascribed to a nodoventricular accessory connection. The accessory pathway in each case demonstrated rate-dependent prolongation of conduction time and a low right ventricular insertion site; it was associated with a left bundle branch block configuration during pre-excitation. Intraoperatively, the pathway was demonstrated to originate at the anterior right atrioventricular (AV) anulus and not at the AV node. These data suggest that a "typical" nodoventricular pathway, by electrophysiologic criteria, may in fact be an AV pathway with AV node-like conduction properties and a distal right ventricular insertion site.

Adult↗

Internal cardiac defibrillation: single and sequential pulses and a variety of lead orientations.

A sequential pulse system for internal cardiac defibrillation incorporating catheter and patch electrodes with two current pathways has been shown to reduce defibrillation threshold in comparison to the single pulse technique. The relative advantage of the sequential pulse over the single pulse technique with other lead systems is not known. We compared defibrillation thresholds using sequential and single pulses delivered to a variety of lead orientations with the same electrode surface areas, when possible. Defibrillation threshold totals determined in halothane-anesthetized open-chest pigs averaged: For the single pulse shock passed between (1) superior vena cava (SVC) and left ventricular apical patch (LVA), 27.2 +/- 9.1 joules (J) and (2) LV epicardial patch (LVE) to right ventricular epicardial (RVE) patch leads, 16.5 +/- 2.1 J; and for the sequential pulse shock with two pulses passed between: (1) the SVC to RV intracavitary apex (RVA) and a quadripolar catheter in the coronary sinus to the RVA, 11.6 +/- 1.0 J; (2) the SVC to LVA and the LVE to RVE, 9.6 +/- 1.3 J and (3) the SVC to RVA and the LVE to RVA, 8.9 +/- 0.4 J. Defibrillation thresholds for sequential pulse shocks were all significantly lower than either of the defibrillation thresholds for single pulse shocks (p less than 0.001). We conclude that the sequential pulse system provides a substantial reduction in defibrillation threshold over the single pulse regardless of the lead system when the surface area and pulse characteristics are controlled. Sequential pulse technique may be valuable in the design of an implantable automatic defibrillator.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Prediction of defibrillation success from a single defibrillation threshold measurement with sequential pulses and two current pathways in humans.

The ultimate aim of defibrillation testing is to predict consistent defibrillation. This study tested the hypothesis that defibrillation success could be predicted from a single measurement of defibrillation threshold. We measured defibrillation threshold by using three patch electrodes and a standard protocol intraoperatively in 49 patients undergoing arrhythmia surgery. Each patient was then assigned to one of five energy subgroups (0.5, 1.0, 1.5, 2.0, or 2.5 times defibrillation threshold) for a single shock (followed by a rescue shock if necessary) for a subsequent ventricular fibrillation episode. A curve relating percent success to energy was then constructed for the group. Defibrillation threshold averaged 4.7 +/- 2.98 J for the group (mean +/- SD). There was a curvilinear relation between the energy of the defibrillation threshold ratio test shock and percent success: 33.3%, 58.3%, 81.8%, 91.7%, and 100% at mean defibrillation threshold ratios of 0.56 +/- 0.14, 1.02 +/- 0.07, 1.53 +/- 0.14, 1.88 +/- 0.09, and 2.60 +/- 0.14, respectively. We conclude that consistent defibrillation is predictable from a single measurement of defibrillation threshold. Furthermore, for an individual patient, a safety margin of 2.6 times defibrillation threshold should approximate 100% successful defibrillation for a single test shock.

Adult↗

A Canadian hospital's experience with the automatic implantable cardioverter/defibrillator.

The automatic implantable cardioverter/defibrillator is a device that can be implanted in patients for treatment of recurrent ventricular tachycardia and ventricular fibrillation. It was recently approved for clinical use in Canada. The authors describe their experience with 12 patients (mean age 51.3 years) who underwent implantation of a defibrillator. All 12 patients had a history of documented ventricular fibrillation, which was idiopathic in 3 and due to ischemic heart disease in 9. Electrophysiologic testing revealed inducible ventricular tachycardia or ventricular fibrillation in 8 of the 10 patients tested. An important criterion for selection for implantation was failure of pharmacologic therapy to suppress ventricular arrhythmias induced during electrophysiologic testing. Of the 12 patients, 1 died within 24 hours after implantation. During a mean follow-up period of 15.5 months there were no further deaths. All the surviving patients expressed satisfaction with the device; five of the seven under the age of 60 years have returned to work, and one has returned to school. This initial favourable experience with the automatic implantable cardioverter/defibrillator suggests that future increases in the availability of the device and improvements in its function will lead to much more widespread use, as the population of patients at risk of sudden cardiac death is large.

Adolescent↗

Relation between clinical presentation and induced arrhythmias in the Wolff-Parkinson-White syndrome.

Electrophysiologic testing is warranted in patients with the Wolff-Parkinson-White (WPW) syndrome presenting with rapid atrial fibrillation (AF) or ventricular fibrillation. Indications are less clear in patients presenting only with atrioventricular reentrant tachycardia (ART). A knowledge of propensity of this latter group to show a rapid ventricular response in the event of AF and the ability of electrophysiologic testing to reproduce the type and rate of clinical arrhythmias are relevant to this decision. The records of 126 symptomatic patients with manifest WPW syndrome were reviewed and separated into 4 groups according to presentation: group 1--AF; group 2--ART; group 3--palpitations suggesting ART; and group 4--AF and ART. All patients except those in group 3 had electrocardiographically documented clinical arrhythmias, and these arrhythmias were compared with those induced during electrophysiologic testing. The shortest RR interval during induced AF and the cycle length of induced ART correlated well with those occurring clinically (r = 0.72, p less than 0.00001), as did the cycle length of induced ART (r = 0.79, p less than 0.00001). Patients presenting with AF (65%) had a higher incidence of atrial vulnerability (48%) and sustained AF at electrophysiologic testing than those presenting with ART (16% and 5%) or undocumented palpitations (27% and 21%). Forty-one percent of patients with ART and 51% with undocumented palpitations had potentially lethal rates (shortest RR interval less than 250 ms) during induced AF. The ability to reproduce clinical arrhythmias and the frequency of rapid rates during AF induced in patients presenting with only ART or undocumented palpitations supports the recommendation for electrophysiologic testing in symptomatic patients with WPW.

Adult↗

Classification of supraventricular tachycardias.

An ideal approach to classification of supraventricular arrhythmias would be based on exact knowledge of the pathophysiology and mechanism of the arrhythmia. Unfortunately, the mechanism may not be apparent from electrocardiographic data or indeed may not be known after extensive invasive and non-invasive studies. Difficulties are encountered in applying and extrapolating to patients criteria that are known to exist in experimental preparations. The traditional methods of classification have used electrocardiographic features and atrial rate. Although such classifications are simple, the criteria are arbitrary and electrocardiographically similar arrhythmias may have different mechanisms. A realistic classification must incorporate both electrocardiographic description and mechanism. The classification should be such that it can readily incorporate new knowledge in an additive way without completely restructuring the classification. A classification fulfilling these requirements would begin with electrocardiographic descriptors and end with mechanism, known or unknown. For example, a tachycardia may be characterized as supraventricular, atrial rate 300, 1:1 atrioventricular relation, with atrioventricular nodal reentry mechanism. It could then be qualified by further clinical descriptors such as incessant, paroxysmal or repetitive. With this approach, the initial descriptive category will always be constant and the mechanism known or unknown. As more data are obtained in future years, the "mechanism" segment of the descriptor may be added or revised.

Atrial Fibrillation↗

Electrophysiologic effects, clinical efficacy and safety of intravenous and oral nadolol in refractory supraventricular tachyarrhythmias.

The electrocardiographic and electrophysiologic effects, clinical efficacy and safety of intravenous and oral nadolol therapy were examined in 34 patients with recurrent supraventricular tachyarrhythmias (SVT) undergoing electrophysiologic evaluation. Programmed electrical stimulation was performed in the control (drug-free) state, after infusion of intravenous nadolol (mean dose 0.09 +/- 0.03 mg/kg) and after chronic oral nadolol therapy in patients who responded to intravenous nadolol (mean dose 83 +/- 12 mg for 5 days). Intravenous nadolol administration prolonged mean sinus cycle length (p = 0.009), mean PR interval (p = 0.001) and mean AH interval (p = 0.001), with no significant electrophysiologic effects in the atrium, ventricle or accessory bypass tracts. Oral nadolol had similar electrocardiographic and electrophysiologic effects, but of lesser magnitude. Intravenous nadolol resulted in complete suppression of induced SVT in 78% of patients with sinus and atrioventricular nodal reentrant tachycardia and 11% of patients with atrioventricular (AV) reentrant tachycardia (p less than 0.001). Partial responses were frequent in intraatrial or AV reentrant tachycardia (37%). Oral nadolol suppressed induction of SVT in patients who responded to intravenous nadolol. Adverse reactions to intravenous and oral nadolol were infrequent--6% and 8%, respectively--and usually did not require drug withdrawal. Intravenous nadolol is highly effective in sinus and AV nodal reentrant tachycardia, and a successful electrophysiologic response to it predicts efficacy of long-term oral nadolol therapy. It has limited efficacy alone in AV reentrant tachycardia and should be considered in combination with other antiarrhythmic therapy in this type of SVT.

Administration, Oral↗

Electrophysiologic effects and long-term efficacy of bepridil for recurrent supraventricular tachycardias.

Thirteen patients underwent electrophysiologic evaluation for recurrent supraventricular tachycardia (SVT). The effects of intravenous bepridil (4 mg/kg) were evaluated during the initial study in 5 patients, and 12 patients underwent repeat study 7 to 10 days later taking oral bepridil, 300 to 400 mg/day. Intravenous bepridil increased the pacing cycle length inducing atrioventricular (AV) (276 +/- 43 vs 334 +/- 31 ms, p less than 0.01) and ventriculoatrial (VA) block (268 +/- 34 vs 310 +/- 35 ms, p less than 0.001), the retrograde refractory period of the accessory pathway (251 +/- 17 vs 295 +/- 25 ms, p less than 0.05) and the ventricular refractory period (216 +/- 17 vs 226 +/- 11 ms, p less than 0.05), and prevented induction of sustained SVT in 3 patients. Oral bepridil increased the sinus cycle length (723 +/- 64 vs 800 +/- 118 ms, p less than 0.05), corrected QT (403 +/- 14 vs 431 +/- 21 ms, p less than 0.05) and the pacing cycle inducing AV (288 +/- 63 vs 353 +/- 78 ms, p less than 0.01) and VA block (271 +/- 31 vs 408 +/- 124 ms, p less than 0.01). It prolonged the refractory period of the atrium (195 +/- 29 vs 233 +/- 36 ms, p less than 0.05), AV node (264 +/- 35 vs 303 +/- 22 ms, p less than 0.05), ventricle (221 +/- 16 vs 245 +/- 21 ms, p less than 0.01), accessory pathway in the AV (290 +/- 47 vs 329 +/- 54 ms, p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Oral↗

Lysophosphoglycerides and ventricular fibrillation early after onset of ischemia.

Lysophosphoglycerides accumulate in ischemic myocardium and induce electrophysiologic alterations in normoxic tissue in vitro closely analogous to those seen during ischemia in vivo. The present study was performed to define the temporal alterations of myocardial phospholipids during the first 3 minutes of ischemia in anesthetized cats and to determine whether the magnitude of the increase in lysophosphoglycerides correlates with the severity of ventricular arrhythmias. Fast-frozen transmural biopsies were obtained simultaneously from the ischemic and non-ischemic zones of the left ventricle. In control animals, values of lysophosphatidylcholine (LPC) did not differ in anterior (2.1 +/- 0.2 nmol/mg protein) compared with lateral (2.2 +/- 0.2 nmol/mg protein) regions of the left ventricular wall. The values for LPC in the anterior and lateral regions were also identical when expressed as % of total phospholipid phosphorus (1.4 +/- 0.1%). Comparing these values to those of all other animals biopsied within 3 minutes of ischemia, no significant increase in LPC was seen (1.7 +/- 0.2%). However, stratification of the animals based on the severity of ventricular arrhythmias showed striking differences. In animals without arrhythmias, no significant change occurred in LPC (1.2 +/- 0.2% phospholipid phosphorus or 2.0 +/- 0.3 nmol/mg protein) compared with the non-ischemic tissue control values (1.4 +/- 0.1% phospholipid phosphorus or 2.1 +/- 0.2 nmol/mg protein). In contrast, in animals with arrhythmias, a striking and significant increase in LPC (to 2.0 +/- 0.2% phospholipid phosphorus or 3.1 +/- 0.3 nmol/mg protein) was seen.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Sensitivity and specificity of invasive and noninvasive testing for risk of sudden death in Wolff-Parkinson-White syndrome.

Invasive electrophysiologic testing and noninvasive testing were compared as methods for identifying patients with Wolff-Parkinson-White syndrome at risk for sudden death. Sixty-seven patients were studied, including nine with a history of ventricular fibrillation. Electrophysiologic testing, using the shortest interval between consecutive pre-excited beats (shortest RR interval) less than or equal to 250 ms during induced atrial fibrillation to define risk, identified seven of nine patients with previous ventricular fibrillation. The sensitivity increased to 87.5% if one patient with prior amiodarone therapy was excluded. Electrophysiologic testing had a specificity of 48.3% and a low predictive accuracy (18.9%) when using the shortest RR interval (less than or equal to 250 ms) to identify the risk for sudden death. Continuous pre-excitation after disopyramide (2 mg/kg body weight, intravenously) had a sensitivity of 71.4%, specificity of 26.1% and predictive accuracy of 12.8% for identifying patients with sudden death. Continuous pre-excitation during an exercise test identified these patients with a sensitivity of 80%, a specificity of 28.6% and a predictive accuracy of 11.8%. These noninvasive tests could also be used to predict the shortest RR interval observed during induced atrial fibrillation. Continuous pre-excitation on both tests used in combination had a sensitivity of 91.2%, a specificity of 66.7% and a predictive accuracy of 75.6% for predicting the shortest RR interval less than or equal to 250 ms. Thus, both invasive and noninvasive techniques have a good sensitivity but a low specificity for identifying patients with Wolff-Parkinson-White syndrome and sudden death.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Cryosurgical modification of the atrioventricular node: a closed heart approach in the dog.

Intraoperative modification of the atrioventricular (AV) node to prolong refractoriness could be an alternative to His bundle ablation in patients with refractory supraventricular arrhythmias. It was postulated that a cryosurgical lesion at the posterior interatrial septum in the closed heart could achieve this. An electrophysiologic study was performed in anesthetized dogs. The AV fat pad was mobilized to expose the posteroseptal region. A cryoprobe cooled to 0 to -10 degrees C was moved in the exposed region until reversible AV block indicated proximity of the AV node. The probe was then cooled to -70 degrees C for 30 seconds. Four weeks later, five dogs had a favorable result with a mean prolongation of Wenckebach cycle length of 45 +/- 7% (p less than 0.05). Two dogs had complete heart block. Decreased (one dog) or increased (one dog) duration of freezing resulted in no change and complete heart block, respectively. Histologic examination verified partial damage to the AV node with preservation of the His bundle. Thus, controlled cryoinjury to modify AV node function is feasible in the closed heart; preservation of AV conduction provides an advantage over His bundle ablation.

Animals↗

Comparison of the ventricular response during atrial fibrillation in patients with enhanced atrioventricular node conduction and Wolff-Parkinson-White syndrome.

Although ventricular fibrillation is a well known sequel to atrial fibrillation in the Wolff-Parkinson-White syndrome, ventricular fibrillation is not generally associated with supraventricular tachycardia in the presence of enhanced atrioventricular (AV) node conduction without pre-excitation. It was hypothesized that the ventricular response during atrial fibrillation may be less in patients with enhanced AV node conduction than in their counterparts with Wolff-Parkinson-White syndrome matched for anterograde effective refractory period. Slower ventricular rates during atrial fibrillation would suggest an increased propensity for concealed conduction in the enhanced AV node conduction group than in the group with an accessory pathway. Three groups of patients aged 16 to 65 years underwent electrophysiologic testing for supraventricular tachycardia or after surgical correction of Wolff-Parkinson-White syndrome. Sixteen patients had enhanced AV node conduction, 16 had Wolff-Parkinson-White syndrome and 16 had normal AV node conduction. Patients with enhanced AV node conduction and Wolff-Parkinson-White syndrome were well matched for anterograde effective refractory period (245 +/- 22 versus 258 +/- 25 ms) and minimal cycle length, maintaining 1:1 anterograde conduction (261 +/- 21 versus 260 +/- 40). There was no difference in intervals during atrial fibrillation (average RR interval = 372 +/- 37 versus 346 +/- 66) or shortest RR interval (266 +/- 27 versus 243 +/- 51). Thus, patients with Wolff-Parkinson-White syndrome and those with enhanced AV node conduction matched for anterograde refractory period exhibit similar ventricular rates during atrial fibrillation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

An algorithm for the electrocardiographic localization of accessory pathways in the Wolff-Parkinson-White syndrome.

Accessory pathway location in the Wolff-Parkinson-White syndrome influences the success and morbidity of nonpharmacological therapies, so that an estimate of accessory pathway location is relevant to the practicing physician. We derived an algorithm for accessory pathway localization based on the surface electrocardiogram; we tested it in a population of 141 patients with the Wolff-Parkinson-White syndrome in whom accessory pathway localization was made by electrophysiological and/or intraoperative mapping. The goal of the algorithm was to localize the accessory pathway to one of four anatomic regions, namely, left free wall, posteroseptal, anteroseptal or right free wall by using a simple, easy-to-apply scheme. Each of two observers, blinded to the results of mapping, correctly identified the anatomic location of 91% and 90% of pathways, respectively. We conclude that a simple algorithm utilizing the 12-lead electrocardiogram can provide a valuable first approximation of accessory pathway location in the Wolff-Parkinson-White syndrome.

Adult↗

Defibrillation threshold: a simple and quantitative estimate of the ability to defibrillate.

It has recently been shown that the probability of successful defibrillation as a function of energy has a sigmoidal dose-response relationship. Determination of a defibrillation "dose-response curve" is time consuming and requires multiple defibrillation attempts. On the other hand, determination of a defibrillation threshold is achieved rapidly and would be better suited to study the effect of interventions on the ability to defibrillate patients. We assessed the relationship of defibrillation threshold to the defibrillation "dose-response curve" in twelve open chest, halothane anesthetized pigs. Ventricular fibrillation was induced electrically, and defibrillation was attempted by passing sequential pulse shocks through an indwelling catheter and plaque electrodes. Defibrillation threshold was determined by decreasing the stored voltage of the initial shock until it failed to defibrillate the heart. Five different stored voltage levels distributed around defibrillation threshold were then randomly administered, six times for each level. A "dose-response curve" was obtained for each animal. Defibrillation threshold superimposed on the "dose-response curve" at 76 +/- 7.2 percent (mean +/- SEM) defibrillation success. Energy delivered at 1.5 times average defibrillation threshold was predicted to achieve 100 percent defibrillation success for a single shock in all animals. We conclude that defibrillation threshold provides a simple and quantitative estimate of the ability to defibrillate with a predictable relationship to the "dose-response curve."

Animals↗

Adrenergic effects on internal cardiac defibrillation threshold.

Autonomic neural tone modulates arrhythmias and could affect the efficacy of an implantable defibrillator if defibrillation threshold is also altered by changes in neural activity. We determined the effects of alpha- and beta-adrenoceptor agonists and antagonists on the energy requirement for defibrillation using a sequential-pulse technique in anesthetized pigs. The doses for each drug were selected based on the results of dose-response curves. The mean defibrillation threshold was 10.2 +/- 0.65 J (mean +/- SE) in control and 10.0 +/- 0.84, 9.4 +/- 0.87 and 8.9 +/- 0.89 J during phenylephrine infusions of 0.7, 1.35, and 2.0-4.0 micrograms X kg-1 X min-1 [n = 8, P = not significant (NS)]. Phenylephrine at all infusion rates increased the ventricular fibrillation threshold, indicating that effects on the ventricular fibrillation threshold may occur independent of changes in defibrillation threshold. No significant change was observed in the defibrillation threshold before and after administration of isoproterenol (6.5 +/- 0.72 and 6.7 +/- 0.93 J, n = 8, P = NS). Similarly, no change in defibrillation thresholds was observed after 1.5-2.0 mg/kg phentolamine (8.5 +/- 0.85 and 7.9 +/- 0.93 J, n = 8, P = NS) or 3.0-6.0 mg/kg atenolol (10.0 +/- 1.7 and 10.3 +/- 2.6 J, n = 8, P = NS). However, when defibrillation threshold was determined using a single-pulse method, isoproterenol infusion produced a significant decrease (17.3 +/- 1.5 vs. 14.6 +/- 1.9 J, n = 7, P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗