Gas chromatographic-mass spectrometric identification and quantitation of benzyl alcohol in serum after derivatization with perfluorooctanoyl chloride: a new derivative.

Benzyl alcohol is commonly used as an antibacterial agent in a variety of pharmaceutical formulations. Several fatalities in neonates have been linked to benzyl alcohol poisoning. Most methods for measuring benzyl alcohol concentrations in serum utilize direct extraction followed by high-performance liquid chromatography. We describe here a novel derivatization of benzyl alcohol using perfluorooctanoyl chloride after extraction from human serum for analysis by gas chromatography-mass spectrometry (GC-MS). The derivative was eluted at a significantly higher temperature respective to underivatized molecule and the method was free from interferences from more volatile components in serum and hemolyzed specimens. Another advantage of this derivatization technique is the conversion of low-molecular-mass benzyl alcohol (Mr 108) to a high-molecular-mass derivative (Mr 504). The positive identification of benzyl alcohol can be achieved by observing a distinct molecular ion at m/z 504 as well as the base peak at m/z 91. Quantitation of benzyl alcohol in human serum can easily be achieved by using 3,4-dimethylphenol as an internal standard. The within run and between run precisions (using serum standard of benzyl alcohol: 25 mg/l) were 2.7% (mean=24.1, S.D.=0.66 mg/l, n = 8) and 4.2% (mean=24.3, S.D.=1.03 mg/l, n = 8), respectively. The assay was linear for the serum benzyl alcohol concentrations of 2 mg/l to 200 mg/l and the detection limit was 0.1 mg/l. We observed no carry-over (memory effect) problem in our assay as when 2 microl ethyl acetate was injected into the GC-MS system after analyzing serum specimens containing 200 mg/l of benzyl alcohol, we observed no peak for either benzyl alcohol or the internal standard in the total ion chromatogram.

Benzyl Alcohol

Gas chromatographic-mass spectrometric determination of serum mexiletine concentration after derivatization with perfluorooctanoyl chloride, a new derivative.

Mexiletine is an antiarrhythmic agent used in the treatment of ventricular arrhythmia. The drug has a narrow therapeutic window which necessitates monitoring its serum concentrations. We describe a gas chromatographic-mass spectrometric analysis of mexiletine using selected ion monitoring. Mexiletine was extracted from alkaline serum with dichloromethane and then derivatized with perfluorooctanoyl chloride. The derivatization reaction was completed in 20 min at 80 degrees C. We used N-propylamphetamine as the internal standard. The ions monitored were m/z 122, 454 and 575 for the derivatized mexiletine and m/z 91, 118, 440 and 452 for the derivatized internal standard. The within-run precision at a serum mexiletine concentration of 1 mg/l was 1.9% (mean=0.98, S.D.=0.019 mg/l, n=7) and the between-run precision was 2.5% (mean=0.99, S.D.=0.025 mg/l, n=7). The assay was linear for serum mexiletine concentrations of 0.2 to 4 mg/l. The detection limit was 0.1 mg/l. The average recoveries of mexiletine and the internal standard were 80% and 84%, respectively at a mexiletine concentration of 1 mg/l. There was no carry over problem in our assay. We observed a good correlation between mexiletine concentrations measured by a reference laboratory (GC) and by our new GC-MS assay.

Caprylates

Tropomyosin isoforms in intestinal mucosa: production of autoantibodies to tropomyosin isoforms in ulcerative colitis.

BACKGROUND & AIMS: Autoantibodies against tropomyosins (TMs) have been reported in ulcerative colitis (UC). In this study the hTM isoforms (hTM1-5) present in intestinal epithelial cells and in smooth muscle were investigated, and the immunoreactivity against hTMs by immunoglobulin G (IgG) produced in vitro by colonic mucosal lymphocytes (LPMCs) from patients with UC, Crohn's disease (CD), and controls was examined. METHODS: TMs were extracted from colonic and jejunal epithelial cells and smooth muscle, and hTM isoforms were identified using isoform-specific monoclonal antibodies by enzyme-linked immunosorbent assay and transblot analysis. The immunoreactivity of IgG produced by colonic LPMCs was analyzed against the recombinant hTM isoforms. RESULTS: The major hTM isoforms present in colonic and jejunal epithelial cells are hTM5 and hTM4, whereas intestinal smooth muscle contains the hTM1-3 isoforms. The IgG synthesized in vitro by LPMCs from UC (n = 19) recognized hTM5 and hTM1, more significantly (P < 0.04 to <0.001) when compared with CD (n = 12) and controls (n = 17). However, IgG produced by LPMCs from CD did not show such anti-hTM reactivity. Mucosal anti-hTM IgG mainly belonged to the IgG1 subclass. CONCLUSIONS: Intestinal epithelial cells and smooth muscle have distinct hTM isoforms. Patients with UC, and not CD, show mucosal autoantibody response against hTM isoforms, particularly hTM5 and hTM1.

Adult

Use of the Trolox assay to estimate the antioxidant content of seventeen edible wild plants of Niger.

Although wild edible plants of the western Sahel and other parts of sub-Saharan Africa are consumed to some extent at all times of the year, greater amounts are consumed when cereal harvests are insufficient to support the populations living in these areas. The purpose of this study was to use a recently reported Trolox-based assay to measure the total antioxidant capacity of aqueous extracts of 17 plants that we gathered from southern Niger. The antioxidant contents of the aqueous extracts were compared to those of spinach and potato. Of the 17 plants, 11 had a greater antioxidant content than spinach and 14 had a greater antioxidant content than potato. The leaves of Tapinanthus globiferus had the greatest antioxidant content, and the fruit of Parinari macrophylla had the lowest. In general, leaves contained more antioxidants than either fruits or seeds. The total antioxidant capacity of the aqueous extracts was relatively high, indicating that the wild plants of the western Sahel may contain substantial amounts of water-soluble flavonoid glycosides, which are potent antioxidants and have been shown to have anticancer properties.

Antioxidants

Rapid automated determination of lipid hydroperoxide concentrations and total antioxidant status of serum samples from patients infected with HIV: elevated lipid hydroperoxide concentrations and depleted total antioxidant capacity of serum samples.

Excessive production of oxygen free radicals causes the oxidation of circulating or membrane lipids, proteins, and DNA. Patients infected with HIV usually have severe malnutrition in the AIDS stage of disease. Therefore, they may be at higher risk of oxidative stress. We measured lipid hydroperoxide concentration, antioxidant status, cholesterol, triglyceride, iron, ceruloplasmin, and transferrin concentrations in the serum samples of 14 patients infected with HIV and compared our results with the results from 14 volunteers who served as controls. Lipid hydroperoxide concentrations in serum samples were measured by a colorimetric assay in which hemoglobin catalyzes the reaction of lipid hydroperoxide with a methylene blue derivative, yielding methylene blue. The total antioxidant capacity of serum was measured by the ability of serum to inhibit the formation of ferrylmyoglobin by metmyoglobin and hydrogen peroxide. Both assays were automated on the Syva-30R analyzer (Behring, San Francisco, Calif). We measured serum cholesterol and triglyceride concentrations by using the Vitro 950 analyzer (Johnson & Johnson, Rochester, NY). The lipid hydroperoxide concentrations were significantly elevated (mean, 1.44; SD, 0.95 micromol/L) in patients with HIV compared with control subjects (mean, 0.25; SD, 0.24 micromol/L). In contrast, the total antioxidant capacity was significantly lower in patients with HIV (mean, 1.04; SD, 0.13 mmol/L of trolox equivalent) compared with control subjects (mean, 1.66; SD, 0.09 mmol/L). We observed a fair correlation between serum lipid hydroperoxide concentrations and serum triglyceride concentrations in patients with AIDS. The correlation between serum hydroperoxide concentration and antioxidant status of serum was relatively poor. The lipid hydroperoxide assay was linear, from 0.1 micromol/L to 50 micromol/L. The within-run and between-run coefficients of variation were 3.5% and 4.5%, respectively, at a lipid hydroperoxide concentration of 2.5 micromol/L. The total antioxidant capacity assay was linear, from 0.1 to 2.5 mmol/L of trolox equivalent. The within-run and between-run coefficients of variation were 1.4% and 4.2% for the standard, with a target total antioxidant capacity of 1.5 mmol/L of trolox equivalent. We conclude that our automated assays for determination of total antioxidant status of serum and lipid hydroperoxide products may be helpful screening tests followed by measuring individual antioxidants, such as tocopherol, ascorbic acid, and other antioxidants for patients with severe deficiency of antioxidant status.

Antioxidants

A rapid novel derivatization of amphetamine and methamphetamine using 2,2,2-trichloroethyl chloroformate for gas chromatography electron ionization and chemical ionization mass spectrometric analysis.

Amphetamine and methamphetamine are commonly abused central nervous system stimulants. We describe a rapid new derivatization of amphetamine and methamphetamine using 2,2,2-trichloroethyl chloroformate for gas chromatography-mass spectrometric analysis. Amphetamine and methamphetamine, along with N-propyl amphetamine (internal standard), were extracted from urine using 1-chlorobutane. The derivatization with 2,2,2-trichloroethyl chloroformate can be achieved at room temperature in 10 minutes. The electron ionization mass spectrum of amphetamine 2,2,2-trichloroethyl carbamate showed two weak molecular ions at m/z 309 and 311, but showed diagnostic strong peaks at m/z 218, 220, and 222. In contrast, chemical ionization of the mass spectrum of amphetamine 2,2,2-trichloroethyl carbamate showed strong (M + 1) ions at m/z 310 and 312 and other strong diagnostic peaks at m/z 274 and 276. The major advantages of this derivative are the presence of a diagnostic cluster of peaks due to the isotopic effect of three chlorine atoms (isotopes 35 and 37) in the derivatized molecule and the relative ease of its preparation. We also observed strong molecular ions for derivatized methamphetamine in the chemical ionization mass spectrum, but the molecular ions were very weak in the electron ionization mass spectrum. We used the scan mode of mass spectrometry in all analyses. When using a urine standard containing 1,000 ng/mL of amphetamine (a 7.4-micromol/L concentration) and methamphetamine (a 6.7-micromol/L concentration), the within-run precisions were 4.8% for amphetamine and 3.6% for methamphetamine. The corresponding between-run precisions were 5.3% for amphetamine and 6.7% for methamphetamine. The assay was linear for amphetamine and methamphetamine concentrations of 250 to 5,000 ng/mL (amphetamine, 1.9-37.0 micromol/L; methamphetamine, 1.7-33.6 micromol/L). The detection limit was 100 ng/mL (amphetamine, 0.74 micromol/L; methamphetamine, 0.67 micromol/L) using the scan mode of electron ionization mass spectrometry. We observed good a correlation between the concentrations of amphetamine and methamphetamine in five urine specimens positive for amphetamines using the more conventional pentafluoropropionyl derivative and our new derivative using 2,2,2-trichloroethyl chloroformate.

Amphetamine

Unexpected suppression of total digoxin concentrations by cross-reactants in the microparticle enzyme immunoassay: elimination of interference by monitoring free digoxin concentration.

The microparticle enzyme immunoassay (MEIA for digoxin (Abbott Laboratories, Abbott Park, Ill) requires no sample pretreatment and is widely used in clinical toxicology laboratories for monitoring serum digoxin concentrations. One advantage of the new MEIA is the lower cross-reactivities with such cross-reactants as digitoxin, oleandrin, and bufalin compared with the fluorescence polarization immunoassay (FPIA)for digoxin. Digitoxin, oleandrin, and bufalin showed positive cross-reactivity with MEIA and FPIAs for digoxin in the absence of the primary analyte, digoxin. A surprising finding was that digoxin concentrations were falsely decreased by these cross-reactants when serum pools containing digoxin were supplemented with various concentrations of these cross-reactants and when digoxin concentrations were measured by the MEIA. In contrast, digoxin concentrations were falsely elevated when measured by the FPIA. For example, when a serum pool containing 2.15 nmol/L of digoxin was supplemented with 129.5 nmol/L of bufalin, the apparent digoxin concentrations were 1.45 nmol/L with the MEIA and 3.00 nmol/L with the FPIA. Taking the advantage of only 25% protein binding of digoxin and more than 95% protein binding of digitoxin and bufalin, we demonstrated that monitoring free digoxin instead of total digoxin eliminated negative interference of digoxin by these cross-reactants in the MEIA and positive interference in the FPIA. Although oleandrin is also strongly bound to serum protein, high concentrations of oleandrin still modestly affect the free digoxin assay for both MEIA and FPIAs.

Bufanolides

Elevated free phenytoin and free valproic acid concentrations in sera of patients infected with human immunodeficiency virus.

Seizures are common in patients infected with human immunodeficiency virus (HIV). Phenytoin and valproic acid are common anticonvulsants, and both drugs are strongly bound to serum albumin. Because patients infected with HIV are often on polytherapy, using homeopathic medicines, and may also have hypoalbuminemia, elevated free drug concentrations may occur in these patients. The authors prepared one serum pool from patients infected with HIV but receiving no bactrim and the other pool from HIV patients receiving bactrim. They supplemented both HIV pools and normal pool (diluted with 0.9% saline to mimic albumin concentration of HIV pools) with a known concentration of phenytoin or valproic acid. After incubation at 37 degrees C for 3 hours, they measured free phenytoin and free valproic acid concentrations in the protein free ultrafiltrates using fluorescence polarization immunoassays. The total drug concentrations in original sera were measured by microparticle enzyme immunoassays. None of the patients had any significant liver or renal disease. The aliquots of HIV pools and normal pool were supplemented with the same concentration of phenytoin or valproic acid. The concentration of free phenytoin and free valproic acid were significantly elevated in patients with HIV (mean = 2.52, SD = 0.11 micrograms/ml for phenytoin; mean = 41.5, SD = 1.5 micrograms/ml for valproate) compared to controls (mean = 1.50, SD = 0.0 7 micrograms/ml for phenytoin; mean = 19.9, SD = 0.5 micrograms/ml for valproate). The concentrations of both free phenytoin and valproic acid were further elevated in patients prepared in the HIV pool who were receiving bactrim (mean = 2.81, SD = 0.09 micrograms/ml for phenytoin; mean = 44.0, SD = 1.1 micrograms/ml for valproate), but when normal serum pool was supplemented with 4.4 mg/dl of bactrim (concentration of bactrim in HIV pool) and supplemented with the same concentration of phenytoin or valproic acid, the observed free concentrations were much lower (mean = 1.65, SD = 0.05 micrograms/ml for phenytoin; mean = 26.1, SD = 1.4 micrograms/ml for valproate). This indicates that hypoalbuminemia and bactrim concentrations do not account for the observed free drug concentrations in patients with HIV. The authors also observed elevated free phenytoin and valproic acid in sera from three individual patients with AIDS compared to normals (normal serum diluted with 0.9% saline to mimic the albumin concentration of serum collected from a patient with HIV and then both specimens supplemented with the same concentration of phenytoin or valproic acid.

Anticonvulsants

Rapid detection of cardioactive bufalin toxicity using fluorescence polarization immunoassay for digitoxin.

Intoxication caused by digitalis-like substances after ingestion of cooked toad soup has been reported. Bufalin, a cardioactive compound, is found in toad. Bufalin is also found in many Chinese medicines. Earlier reports demonstrated cross reactivity of bufalin with fluorescence polarization immunoassay for digoxin. In this report, the authors demonstrated a significantly higher cross reactivity of bufalin with the fluorescence polarization assay for digitoxin. They supplemented aliquots of normal plasma that had various concentrations of bufalin (1 to 50 micrograms/ml) from a local blood bank and measured apparent digitoxin concentrations using fluorescence polarization immunoassay and chemiluminescent assays (ACS digitoxin) for digitoxin. They measured apparent digoxin and digitoxin concentrations using fluorescence polarization, microparticle enzyme immunoassay, and chemiluminescent assays for digitoxin. They observed apparent digitoxin or digoxin concentrations in sera supplemented with bufalin only with the fluorescence polarization assays. For example, the apparent digitoxin concentration observed in a serum supplemented with 25 ng/ml of bufalin was 24.3 ng/ml of digitoxin equivalent. The apparent digoxin concentration observed in the same specimen was 1.33 ng/ml digoxin equivalent. Bufalin caused positive interference in serum digoxin or digitoxin measurements in specimens containing digoxin or digitoxin when concentrations were measured by fluorescence polarization assays. In contrast, bufalin lowered the measured digoxin concentrations in serum pools containing digoxin when digoxin concentrations were measured by the microparticle enzyme immunoassay. The authors conclude that bufalin toxicity can be rapidly detected by the fluorescence polarization assay for digitoxin.

Animals

Gas chromatography-electron ionization and chemical ionization mass spectrometric analysis of serum mexiletine concentration after derivatization with 2,2,2-trichloroethyl chloroformate: a novel derivative.

Mexiletine (Mexitil) is an antiarrhythmic agent used in the treatment of ventricular arrhythmia. The drug has a narrow therapeutic window, and monitoring its serum concentration is recommended. The authors describe a gas chromatography-mass spectrometric (GC/MS) assay of mexiletine using selected ion monitoring. Mexiletine was extracted from alkaline serum with dichloromethane followed by derivatization with 2,2,2-trichloroethyl chloroformate. The reaction was completed in 30 minutes at 70 degrees C. N-propylamphetamine was used as the internal standard. The ions monitored were m/z 58, 102, 122, 232, and 234 for derivatized mexiletine and m/z 56, 91, 131, 260, and 262 for the derivatized internal standard. The within-run precision at a serum mexiletine concentration of 1 mg/l was 1.7% (mean = 0.981, SD = 0.017 mg/l, n = 8) and the between-run precision was 3.3% (mean = 0.983, SD = 0.033 mg/l, n = 6). The assay was linear for serum mexiletine concentrations of 0.2 to 2.5 mg/l. The detection limit was 0.1 mg/l. The authors observed no carry-over problem in their assay. They observed a good correlation between mexiletine concentrations measured by a reference laboratory (Associated Regional University Pathologists, Salt Lake City, UT, U.S.A.) and by the new GC/MS assay.

Anti-Arrhythmia Agents

Bidirectional (positive/negative) interference in a digoxin immunoassay: importance of antibody specificity.

The importance of high specificity in immunoassays used in therapeutic monitoring is highlighted by a case study in which therapeutic-to-toxic borderline digoxin levels were measured by a digoxin immunoassay in the serum sample from a patient administered digitoxin rather than digoxin. The sample, mistakenly sent to the laboratory for digoxin analysis, gave discordant results in three digoxin immunoassays: 1.99 and 0.79 ng/ml in assays using polyclonal antibodies (fluorescence-polarization immunoassay and microparticle enzyme immunoassay, respectively), and <0.1 ng/ml in a chemiluminescent immunoassay using more specific monoclonal antibody. The presence of digitoxin (approximately 40 ng/ml) in the sample was confirmed by three different digitoxin immunoassays. Based on these results, the interference of different levels of digitoxin was studied in the presence of 0, 0.85, 1.9, and 4.7 ng/ml digoxin in all three digoxin assays. The chemiluminescent assay showed no significant interference. The fluorescence-polarization immunoassay showed positive interference in all cases; however, the microparticle enzyme immunoassay showed a bidirectional interference: a positive interference observed at digoxin level <1.8 ng/ml, changing to a negative interference at higher digoxin concentrations. The authors conclude that in countries such as Germany, where both digoxin and digitoxin may be prescribed, caution should be used to interpret digoxin immunoassay results. Digoxin assays, with cross-reactivity to digitoxin <0.1% should be used.

Antibody Specificity

Herpes simplex virus DNA packaging without measurable DNA synthesis.

Herpes simplex virus (HSV) type 1 DNA synthesis and packaging occur within the nuclei of infected cells; however, the extent to which the two processes are coupled remains unclear. Correct packaging is thought to be dependent upon DNA debranching or other repair processes, and such events commonly involve new DNA synthesis. Furthermore, the HSV UL15 gene product, essential for packaging, nevertheless localizes to sites of active DNA replication and may link the two events. It has previously been difficult to determine whether packaging requires concomitant DNA synthesis due to the complexity of these processes and of the viral life cycle; however, we have recently described a model system which simplifies the study of HSV assembly. Cells infected with HSV strain tsProt.A accumulate unpackaged capsids at the nonpermissive temperature of 39 degrees C. Following release of the temperature block, these capsids proceed to package viral DNA in a single, synchronous wave. Here we report that, when DNA replication was inhibited prior to release of the temperature block, DNA packaging and later events in viral assembly nevertheless occurred at near-normal levels. We conclude that, under our conditions, HSV DNA packaging does not require detectable levels of DNA synthesis.

Animals

A small yeast RNA blocks hepatitis C virus internal ribosome entry site (HCV IRES)-mediated translation and inhibits replication of a chimeric poliovirus under translational control of the HCV IRES element.

Hepatitis C virus (HCV) infection frequently leads to chronic hepatitis and cirrhosis of the liver and has been linked to development of hepatocellular carcinoma. We previously identified a small yeast RNA (IRNA) capable of specifically inhibiting poliovirus (PV) internal ribosome entry site (IRES)-mediated translation. Here we report that IRNA specifically inhibits HCV IRES-mediated translation both in vivo and in vitro. A number of human hepatoma (Huh-7) cell lines expressing IRNA were prepared and characterized. Constitutive expression of IRNA was not detrimental to cell growth. HCV IRES-mediated cap-independent translation was markedly inhibited in cells constitutively expressing IRNA compared to control hepatoma cells. However, cap-dependent translation was not significantly affected in these cell lines. Additionally, Huh-7 cells constitutively expressing IRNA became refractory to infection by a PV-HCV chimera in which the PV IRES is replaced by the HCV IRES. In contrast, replication of a PV-encephalomyocarditis virus (EMCV) chimera containing the EMCV IRES element was not affected significantly in the IRNA-producing cell line. Finally, the binding of the La autoantigen to the HCV IRES element was specifically and efficiently competed by IRNA. These results provide a basis for development of novel drugs effective against HCV infection.

Autoantigens

Lysosomal enzymuria in protein energy malnutrition.

Protein energy malnutrition (PEM) is common in underprivileged populations in many parts of the world and results from diets deficient in protein (kwashiorkor) or protein and calories (marasmus). The literature documents renal tubular abnormalities in children with PEM. In PEM the reabsorption of amino acids and phosphate is defective. In many kidney disorders in which renal tubular function is impaired (e.g., diabetes, preeclampsia, nephrotic syndrome, sickle cell anemia), lysosomal enzymuria ensues. We compared the urinary excretion of the following five lysosomal enzymes in 31 Nigerian children with marasmus, kwashiorkor, or marasmic-kwashiorkor: beta-hexosaminidase, alpha-galactosidase, beta-galactosidase, beta-glucuronidase, and alpha-mannosidase. All of the protein energy malnourished children and the 18 age- and gender-matched controls were from the city of Jos, located in central Nigeria. In the severely malnourished children, the urine levels of all five lysosomal enzymes (expressed as units of enzyme activity per mg creatinine) were markedly increased. The greatest increases were seen with beta-hexosaminidase (16-fold) and beta-glucuronidase (14-fold). Routine clinical analyses also revealed that, relative to the control population, the sera of the 14 most severely malnourished patients contained 2- to 5-fold more vitamin B12 and markedly reduced levels (15%, p < 0.00001) of calcium. These data are significant in that they document lysosomal enzymuria in Nigerian children with severe PEM and point to the potential diagnostic utility of the urinary beta-galactosidase determination for assessing renal function in children with this disorder.

Child, Preschool

Erosion of implantable cardioverter defibrillator patch electrode into airways: an unusual cause of recurrent hemoptysis.

A 74-year-old man presented with a 9-month history of recurrent hemoptysis. He had implantable cardioverter defibrillator (ICD) patch electrodes placed 4 years before. A chest x-ray film showed crinkling of his posteriorly placed ICD patch which also appeared to have separated from his ventricle on a CT scan of the chest. Bronchoscopy localized the ICD patch electrode to the lower lobe of the left lung. He underwent a lobectomy and was treated with antibiotics at home. In patients with known ICD implantation, patch erosion into the airways should be considered in the differential diagnosis of recurrent hemoptysis.

Aged

Self-expandable metallic airway stent insertion employing flexible bronchoscopy: preliminary results.

We describe 37 patients in whom 52 self-expandable metallic stents were successfully placed using a flexible bronchoscope. Indications for stenting were tracheobronchomalacia (n=13), neoplasia (n=20), and tracheal stenosis (n=4). Airway patency was restored in all patients. Symptoms improved in all but one patient. The median follow-up for all patients and the group of 16 patients alive has been 21 and 69.5 weeks, respectively. Complications have included granulomas and bronchitis. Migration or mucus plugging was not encountered. We conclude that metallic stents can be inserted safely using a flexible bronchoscope. At least in the short term, major complications are uncommon.

Adult