PubMed Health⌕ Search

Biomedical subjects

A De Miguel

Publications and source records attributed to A De Miguel.

6 recordsLinked to original sources

[Anesthesia and postoperative care of 11 patients undergoing peritonectomy and hypothermic intraperitoneal chemotherapy].

Peritoneal carcinomatosis is the final stage of certain malignant tumors located both inside and outside the abdomen. Mortality is high with conventional treatments and the best mean survival rates reported have reached up to 6 months. One technique tried in recent years involves resection of macroscopic parietal and visceral peritoneal lesions (peritonectomy) combined with intra- and postoperative perfusion of the abdominal cavity with hyperthermic chemotherapy to treat residual microscopic lesions. Five-year survival in series so-treated can reach as high as 80%, depending on tumor histology. Anesthetic management in these patients is complex, particularly because of the aggressive nature of the procedure. The main complications are related to the long duration of surgery, bleeding secondary to the many surgical resections, and hyperthermia caused by the chemical agents. The therapeutic process, therefore, is not risk-free and involves high rates of morbidity and mortality. We describe the anesthetic and postoperative management of the first 11 cases in which this procedure was carried out at our hospital, analyzing the main complications arising.

Adult↗

Influence of methylene blue photoinactivation treatment on coagulation factors from fresh frozen plasma, cryoprecipitates and cryosupernatants.

OBJECTIVE: To study the influence of virus photoinactivation with methylene blue (MB) on the coagulation factors of fresh frozen plasma (FFP) and the corresponding cryoprecipitates and cryosupernatants derived from it. MATERIALS AND METHODS: The photoinactivation procedure of the German Red Cross (Springe) was applied using Biomat (Grifols, Spain). Twenty isogroup pools of three plasma units were made from 60 U of FFP. The pools were split into three bags. One of them was photoinactivated, and pre- and postinactivation samples (MB-plasma) were obtained. The second bag was treated in the same way, followed by the preparation of MB-cryoprecipitate and MB-cryosupernatant. The third bag was not photoinactivated, and was processed in the same way to obtain control cryoprecipitate and cryosupernatant. The prothrombin time and activated partial thromboplastin time were analysed, as well as fibrinogen, factors (F) II, V, VII, VIII, IX, XI and XIII, antithrombin III, von Willebrand (vW) F:RCo, vWF:Ag and the multimeric structure of vWF. RESULTS: In plasma, the proteins most sensitive to photoinactivation were fibrinogen, FV, FVIII, FIX and FXI (24, 32, 28, 23 and 27% loss, respectively). In the MB-cryoprecipitate, the losses were higher for FVIII (23%), moderate for fibrinogen, FXIII and vWF:RCo (18, 14 and 13%, respectively) and minimal (only 3%) for vWF:Ag. In MB-cryosupernatants, the losses were higher for FV (26%) and moderate for fibrinogen (16%), FIX (18%) and FXI (19%), as well as for FII and FXIII (15%). The multimeric structure of vWF was not modified in MB-plasma or in MB-cryoprecipitates. The supernatants (both MB treated as well as controls) showed an absence of multimers of very high and high molecular weight. CONCLUSIONS: The quantitative and qualitative conservation of coagulation factors achieved in MB-plasma-derived products suggest that they are useful for the global replacement of coagulation factors and for deficiencies in FV and FXI. In countries lacking the economic resources to obtain virally inactivated concentrates, MB-cryoprecipitates could be useful in von Willebrand's disease and fibrinogen and FXIII deficiencies. MB-cryosupernatants could be employed in thrombotic thrombocytopenic purpura, in the correction of total or partial deficiencies of prothrombin complex factors and in specific deficiencies of FV and FXI.

Antiviral Agents↗

Quality analysis of blood components obtained by automated buffy-coat layer removal with a top & bottom system (Optipress (R)II).

BACKGROUND AND OBJECTIVE: There are Council of Europe recommendations for the quality of blood components. We analyzed the quality of blood components processed by a top & bottom system (Optipress((R)) II), the routine method used in our blood bank, to test whether the components reached the recommended quality. DESIGN AND METHODS: Blood was collected in triple CPD-SAGM bags (Optipac((R)) Baxter). Whole blood (WB) was centrifuged at 4,158 g for 14 min before separation by an automated top & bottom system (Optipress((R) )II). Platelet concentrate (PC) was prepared by pooling four isogroup buffy-coat (BC) units before low-speed centrifugation, and transferring the supernatant (4 BC-PC) to a 5-day storage bag (PL732, Baxter). An alternative approach involved PC preparation from a single BC unit by adding approximately 70 mL of plasma before centrifugation, followed by transfer of the platelet concentrate (1BC-PC) to a 300 mL Teruflex((R)) transfer bag. Both 4 BC-PC and 1 BC-PC were stored in a flat agitator at 22 degrees C for up to 5 days after collection. Cell counts were determined, along with hemoglobin and hematocrit in a Sysmex K-800 cell counter. The pH was determined on day 5 at 22 degrees C. Weights were measured and volumes were calculated based on specific gravity. Statistical analyses were carried out using the Kolmogorov-Smirnov test as a normality distribution test, the t-test for parametric values and Wilcoxon's test as a non-parametric test. Statistical significance between samples was considered to have been reached when p<0.05. RESULTS: The best parameters for configuring the system were: strength 25; BC volume 33-55; level of BC 5.5. Red blood cell (n = 1,434) volume was 279+/-20 mL, with 54.92+/-7.16 g of hemoglobin. More than 96% of units had fewer than 1.2x10(9) white blood cells. Fresh plasma volume (n = 803) averaged 279+/-19 mL, with a white blood cell contamination of fewer than 0.1x10(9)/L in all samples examined (n = 23). Platelet recovery in BC was 92+/-9% of platelets present in WB; the percentage of removed leukocytes was 74+/-10%, and between 13 and 15% of RBCs were lost in the BC (95% confidence interval). The BC volume (n = 1,037) fitted the target volume of 60 mL, except for some devices, when Optipress II((R)) lost the configuration for this parameter. Of 4 BC-PCs 80.3% yielded more than 0.6x10(11) platelets per unit, whereas this criterion was only met by 59.7% of 1 BC-PCs, and a greater proportion of 1 BC-PCs (58.8%) showed pH values within the range of 6.5-7.4 after 5 days of storage in comparison with 4 BC-PCs (44.25%). INTERPRETATION AND CONCLUSIONS: Optipress II((R)) provides standardized, leukocyte-poor blood components. Council of Europe requirements were met in a large percentage of red-cell concentrates, with less than 92 and 74% of the original platelets and leukocytes, respectively, and a small hemoglobin loss per unit. The system gave an optimal yield in terms of plasma volume. The top & bottom technique allowed us to reduce the number of blood units per platelet concentrate from 6 to 4 units, with similar platelet yields compared with traditional procedures. Nevertheless, the storage conditions must be improved to satisfy all Council of Europe requirements for platelet concentrates.

Blood Cell Count↗

A new method for phenotyping red blood cells using microplates.

BACKGROUND AND OBJECTIVES: The supply of phenotyped red blood cells (RBC) for patients with several RBC antibodies presents a difficult task to hospital blood banks and regional blood centers. The aim of this study was to establish a low-cost typing system to allow extensive phenotyping of regular blood donors for clinically significant RBC antigens. MATERIALS AND METHODS: We developed a new buffer that greatly intensifies the antigen-antibody reaction and thus reduces the quantity of serum needed for phenotyping. The procedure was carried out on microplates. RESULTS: A total of 20,435 regular blood donors have been typed to date. For 752 units required for transfusion, 3,584 phenotyping tests were performed, validating the results by tube or gel typing methods; agreement was achieved in all cases. CONCLUSION: This technique seems adequate for phenotyping a large number of RBC units at very low cost, thus facilitating the availability of phenotyped blood.

Antibodies↗

Cytogenetic study of a patient with the Sézary syndrome.

A cytogenetic study was performed in a patient with Sézary syndrome, which is a T-helper lymphoproliferative disorder. Metaphases were obtained from a phytohemagglutinin-stimulated lymphocyte culture. Normal, hypodiploid (42 to 45 chromosomes) and hypotetraploid (84 to 88 chromosomes) cells were observed. Both abnormal cell lines showed the same abnormalities involving chromosomes 1, 2, 4, 6, 10, 11, 12, 14, 16, and 20.

Aged↗