PubMed Health⌕ Search

Biomedical subjects

A Dessl

Publications and source records attributed to A Dessl.

At least 19 recordsLinked to original sources

Virtual endoscopy for planning neuro-endoscopic intraventricular surgery.

To evaluate the usefulness of virtual endoscopy (VE) in planning neuroendoscopic intraventricular surgeries, the technique was applied in 20 of 22 consecutive procedures. Thirteen endoscopic third ventriculostomies (ETV) in 12 patients, 3 endoscopic colloid cyst removals, 1 third ventricular arachnoidal cyst fenestration, 1 endoscopic ventricul-cysto-cisternostomy (suprasellar arachnoidal cyst), 1 endoscopic tumor biopsy, one third ventricular gross total tumor removal and 2 septostomies at the foramen of Monro due the septal occlusion were performed. Contrast medium-enhanced MR images (3DMPRAGE, Siemens, Germany) were semi-automatically segmented with a surface-rendering technique ("Navigator" software, General Electric Medical, Buc, France) to produce the virtual endoluminal views. Surgery was performed with cerebral ventriculoscopes by Wolf (Richard Wolf, Knittlingen, Germany). VE was feasible in all patients and the virtual endoscopic images were comparable with the real intraventricular views obtained by standard rod lens systems. After contrast medium administration intra- and paraventricular vessels such as the thalamocaudate vein, the septal veins, the basilar artery and its branches (distal BA complex) and the choroid plexus were identified on the virtual endoscopic images. In 8 patients, the additional anatomic information provided by VE profoundly influenced surgical planning. VE provides the neurosurgeon with additional morphological information supporting the planning process of neuroendoscopic intraventricular surgeries, contributing to the safety of the procedures.

Adolescent↗

Color and pulsed Doppler ultrasound findings in normally functioning transjugular intrahepatic portosystemic shunts.

OBJECTIVE: To evaluate blood flow changes inside normally functioning transjugular intrahepatic portosystemic shunts (TIPS), using color Doppler ultrasound (CDUS) and pulsed Doppler ultrasound (PDUS). METHODS: A total of 72 patients (mean age 54, range 36-78 years) underwent TIPS placement, portal angiography, CDUS and PDUS examinations. Measurements inside the stent were taken at the portal side, at the central part and at the venous end of the TIPS. RESULTS: In well functioning TIPS the mean peak velocity (PV) on the portal side was 37 m/s (range 22-65 cm/s), in the area of the incoming intrahepatic portal branch the mean PV was 59 cm/s (range 40-95 cm/s) and at the side of the incoming hepatic vein the mean PV was 135 cm/s (range 88-220 cm/s). In the punctured hepatic and portal veins the mean PV was 25 cm/s (range 15-30 cm/s) and 18 cm/s (10-22 cm/s), respectively. The flow increase from the portal to the mid part (P less than or = 0.001) and to the venous side was statistically significant (P less than or = 0.001). CONCLUSION: A velocity gradient between the portal and the venous side of a TIPS is a normal finding caused by branches of the portal and hepatic vein joining the TIPS from the side and it is characteristic of a normally functioning TIPS.

Adult↗

Virtual endoscopy for planning endoscopic third ventriculostomy procedures.

Virtual endoscopy was used to plan 10 endoscopic third ventriculostomy procedures in 9 patients suffering from occlusive hydrocephalus due to idiopathic aqueductal stenosis and tumors. The patients were 4 children (4-14 years, mean age: 9 years) and 5 adults (21-38 years, mean age: 29 years). The aim of the study was to preoperatively evaluate the individual intraventricular and vascular endoscopic anatomy at the floor of the third ventricle based on virtual endoscopic images. The virtual views were correlated with the real endoscopic images, intraoperatively obtained by a standard ventriculoscope (Wolf, Knittlingen, Germany) during endoscopic third ventriculostomy procedures. Contrast-medium-enhanced MR images (3D-MPRAGE; Siemens, Germany) were semiautomatically segmented with a surface-rendering technique ('Navigator' software; General Electric Medical, Buc, France) to produce the virtual endoluminal views. The virtual endoscopic images were comparable with the real intraoperative endoscopic view in 8 of 9 patients. Virtual endoscopy can display the position of the basilar artery, the posterior cerebral arteries and the posterior communicating arteries in their relationship to the mammillary bodies and the clivus. Preoperative virtual endoscopy planning can intraoperatively assist the neurosurgeon to find a safe location for third ventriculostomy.

Adolescent↗

Computer-assisted neurosurgery by using a noninvasive vacuum-affixed dental cast that acts as a reference base: another step toward a unified approach in the treatment of brain tumors.

OBJECT: The purpose of the study was to evaluate the use of the Vogele-Bale-Hohner (VBH) mouthpiece, which is attached to the patient's upper jaw by negative pressure, for patient-image registration and for tracking the patient's head during image-guided neurosurgery. METHODS: A dynamic reference frame (DRF) is reproducibly mounted on the mouthpiece. Reference points, optimally distributed and attached to the mouthpiece, are used for registration in the patient's absence on the day before surgery. In the operating room, the mouthpiece and DRF are precisely repositioned using a vacuum, and the patient's anatomical structures are automatically registered to corresponding ones on the image. Experimental studies and clinical experiences in 10 patients confirmed repeated (rigid body) localization accuracy in the range of 0 to 2 mm, throughout the entire surgery despite movements by the patient. CONCLUSIONS: Because of its noninvasive, rigid, reliable, and reproducible connection to the patient's head, the VBH vacuum-affixed mouthpiece grants the registration device an accuracy comparable to invasive fiducial markers.

Adult↗

Virtual neuroendoscopy, a comparative magnetic resonance and anatomical study.

We evaluated the usefulness and reliability of intraventricular virtual neuroendoscopy based on a comparative anatomical study. Virtual intraventricular endoscopic images were calculated from 3D magnetic resonance images in five anatomic specimens. Contiguous 1.2 mm slices of the specimen heads were acquired at a 1.5 T MR scanner using a 3D-gradient echo sequence. The images were then transferred to an independent 3D-workstation (Sun Spark 20). After scanning the specimen heads, real endoscopy within the cerebral ventricles of these brains was performed with a standard rod lens system. Comparison between real and virtual endoscopic views of the intraventricular topography was based on the same anatomical reference and landmarks. Acquisition of MR data and virtual image post-processing have been possible in all specimens. The virtual endoscopic images of the ventricles were comparable to the intraventricular views obtained by a standard rod lens system. Virtual intraventricular neuroendoscopy can be employed for planning and simulating neuroendoscopic procedures. It enables the neurosurgeon to simulate the endoscopic procedure within the cerebral ventricles on the basis of the patient's individual anatomy prior to surgery.

Cerebral Ventricles↗

Sonographic appearance of an appendix carcinoma.

Malignant appendix tumours are rare entities. Especially adenocarcinomas, which only appear in about 10% of appendix tumours, are very seldom. Preoperative diagnosis is very difficult due to a lack of typical clinical signs and a clinical appearance mimicking perforated appendicitis. Nevertheless, sonography is able to show indirect signs and therefore it can provide the surgeon with more information for a better operative treatment.

Adenocarcinoma↗

[Ruptures of the medial gastrocnemius muscle: diagnosis with high resolution ultrasound].

AIM: Evaluation of high resolution ultrasound to diagnose rupture of the medial head of gastrocnemius muscle in patients with uncharacteristic calf pain. METHOD: 66 patients with clinically unclear calf pain were examined in a prospective study. RESULTS: Out of 66 patients, 51 showed sonographic criteria of a partial rupture of the medial gastrocnemius head. 47 ruptures were located in musculotendineus transition zone. CONCLUSION: High resolution sonography detect minimal lesions of the medial gastrocnemius muscle in patients with clinically uncharacteristic calf pain.

Adult↗

[ACOnet (Austrian Academic Computer Network) as data carrier for teleradiologic consultations].

PURPOSE: To assess the feasibility of image transfer for teleradiologic consultations using the Austrian Academic Computer Network (ACOnet). The ACOnet corresponds between the main universities to a MAN (Metropolitan Area Network) with a transfer rate of 4 Mbps. Its use is free of charge for university institutions. MATERIALS AND METHODS: 1740 test image data sets and 620 image data sets for teleradiological consultations were exchanged without annotations between the Departments of Diagnostic Radiology of the universities of Innsbruck and Graz, using the ACOnet. RESULTS: Data transmission was reliable and fast with an average transfer capacity of 170.2 kBytes/s (94-341 kBytes/s). There were no major problems with image transfer during the test phase. CONCLUSION: Due to its high transfer capacity, the ACOnet is considered a reasonable alternative to the ISDN service.

Austria↗

MR findings in tibial adamantinoma. A case report.

Adamantinoma of the long bones is a rare skeletal tumor and its MR features have seldom been reported. It is difficult to distinguish from other bone lesions (such as osteofibrous dysplasia or osteosarcoma) by means of conventional radiography and CT. MR imaging, however, may be useful in differentiating adamantinoma from such lesions. With this presentation of a typical case, we hope to draw the attention of radiologists to this lesion and contribute information on its MR appearance.

Adult↗

The Austrian Academic Computer Network and its usefulness for teleradiology.

To study the value of the Austrian Academic Computer Network (ACOnet) for teleradiology, 1740 test image data-sets and 620 image data-sets were exchanged between the departments of diagnostic radiology of the Universities of Innsbruck and Graz using the ACOnet service. Data transmission was reliable and fast with an average transfer capacity of 170 kByte/s (range 94-341). During the test phase, no major problems with image transfer occurred. Assuming that problems like security of patient data-sets, data compression and data verification can be solved, the ACOnet service would be a useful additional tool for telemedicine applications throughout Austria and eastern Europe.

Austria↗

Virtual computed tomography gastroscopy: a new technique.

BACKGROUND AND STUDY AIMS: The aim of the present study was to establish a suitable method for virtual computed tomography (CT) gastroscopy. PATIENTS AND METHODS: Three-millimeter helical CT scans of a pig stomach were obtained after air insufflation and instillation of diluted diatrizoic acid (Gastrografin), and with double contrast. In addition, three patients with gastric tumors were studied after ingestion of an effervescent agent (Duplotrast, 6 g) and intravenous injection of hyoscine butylbromide (Buscopan, 1 ml). Virtual endoscopy images were computed on a Sun Sparc 20 workstation (128 megabytes of random access memory, four gigabytes of hard disk space), using dedicated software (Navigator, General Electric Medical System Company). The endoscopy sequences were compared with real endoscopic examinations and with anatomical specimens. RESULTS: In the cadaver studies, the best results were obtained with plain air insufflation, whereas virtual CT gastroscopy with diluted contrast and with double contrast showed artifacts simulating polyps, erosions, and flat ulcers. Patient studies showed good correlation with the fiberoptic endoscopy findings, although large amounts of retained gastric fluid substantially reduced the quality of the surface reconstruction. CONCLUSION: These preliminary results show that virtual CT gastroscopy is able to provide insights into the upper gastrointestinal tract similar to those of fiberoptic endoscopy. However, due to the limited spatial resolution of the CT protocol used, as well as inherent image artifacts associated with the Navigator program's reconstruction algorithm, the form of virtual CT gastroscopy studied was not capable of competing with the imaging quality provided by fiberoptic gastroscopy.

Animals↗

A cost analysis of an emergency computerized tomography teleradiology system.

We carried out a cost analysis of a teleradiology system for emergency computerized tomography (CT) examinations. Teleradiology was implemented by connecting two spiral CT scanners in the University Hospital in Innsbruck and the Regional Hospital in Zwettl. It enabled the remote hospital in Zwettl to get fast and competent reports of emergency CT examinations when there was no specialist radiologist available. In 13 months' use for routine night and weekend service, the system proved fast and reliable. During the study period 121 emergency examinations of 116 patients were transmitted from Zwettl to Innsbruck. The fixed costs of teleradiology were for the ISDN connection and amounted to DM230 plus DM696/year rental. The average cost of one emergency CT examination by teleradiology was DM372 (range 308-453). One possible alternative, transporting the films by taxi for reporting elsewhere, was cheaper (estimated cost DM156), but would have been much slower. Another alternative, transporting the patient to the nearest central hospital for scanning, was much more expensive: DM524 by road or DM4667 by helicopter ambulance.

Austria↗

[Virtual endoscopy with post-processing helical CT data sets].

PURPOSE: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n = 2), the tracheobronchial system (n = 3), the nasal sinuses (n = 2), the colon (n = 2), and the common carotid artery n = 1). Software developed specifically for virtual endoscopy ("Navigator") was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. RESULTS: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Through use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. CONCLUSIONS: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware.

Artifacts↗

[Open questions on the topic of teleradiology from the current viewpoint].

A review on the theoretical challenges and potential risks of teleradiology is given. Based on the authors two years clinical experience and the current literature unsolved problems are discussed, which are to a smaller extent the technical implementation but much more the still missing regulation of various concomitant circumstances.

Computer Security↗