PubMed Health⌕ Search

Biomedical subjects

A Dhala

Publications and source records attributed to A Dhala.

At least 37 records · Page 2Linked to original sources

Sinus tachycardia with atrioventricular block: an unusual presentation during neurocardiogenic (vasovagal) syncope.

INTRODUCTION: Neurocardiogenic (vasovagal) syncope is characterized by hypotension and bradycardia. The presence of sinus tachycardia along with AV block during syncope in patients with neurocardiogenic syncope has not been described previously. METHODS AND RESULTS: Two female patients (18 and 16 years old) with recurrent syncope and documented sinus tachycardia at the time of syncope are described. Patient 1 had recurrent episodes of syncope. During one of these episodes, which occurred while she was being monitored, sinus tachycardia along with high-grade AV block was seen at the time of syncope and hypotension. Patient 2 had a history of recurrent syncope and seizure. During one of these episodes, she was documented to have ventricular asystole lasting for about 39 seconds. The sinus rate was 480 msec at the beginning, before slowing down to 960 msec prior to restoration of sinus rhythm with 1:1 AV conduction. The same scenario was repeated during head-up tilt testing. Both patients were treated successfully with oral disopyramide and, during a follow-up of 28 months and 9 months, have remained symptom-free. CONCLUSION: Sinus acceleration along with high-grade AV block during syncope and hypotension can occur in some patients with neurocardiogenic syncope. The exact mechanism of this phenomenon is unclear.

Adolescent↗

Catheter ablation of atrial flutter using radiofrequency current: cumulative experience in 61 patients.

UNLABELLED: We present our experience with radiofrequency catheter ablation of common atrial flutter. METHODS: Radiofrequency ablation of atrial flutter was performed utilizing percutaneous techniques and the anatomic approach under conscious sedation or general anesthesia. RESULTS: Sixty-one consecutive patients (51 men, and 10 women) aged 59 +/- 12 years with medically refractory atrial flutter underwent catheter ablation. Thirty-eight patients (62%) had structural heart disease, including complex congenital anomalies in one patient. Atrial flutter ablation was successfully accomplished in 55 patients (90%) in one session. There were no complications, and all patients were discharged within 24-hours of the procedure. During a mean follow-up of 10 +/- 9 months, recurrent atrial flutter occurred in 11 patients (18%), eight of which successfully underwent repeat atrial flutter ablation. CONCLUSIONS: Catheter ablation of atrial flutter using radiofrequency current is safe and has a high success rate. This nonpharmacologic approach should be considered as the first line of therapy for common atrial flutter prior to the institution of antiarrhythmic drugs.

Adolescent↗

Advances in the care of children with heart disease.

As we enter the next millennium, we are encouraged by the progress that has been made in the care of neonates, infants, and children with heart disease. Surgical repair can be offered at an earlier age with excellent results. Diseases that were uniformly fatal in the past have improved outcomes. Research continues in the area of interventional devices such that surgical repair might be eliminated or delayed. We continue to look forward to advances in the next several years that will allow for future improvement in outcome, better quality-of-life and better long-term results.

Child↗

Implantable atrial defibrillator for atrial fibrillation.

Atrial fibrillation is a common problem. Pharmacological and nonpharmacological approaches have limited therapeutic efficacy in many patients. Low energy transvenous atrial defibrillation using catheters positioned inside the right atrium and cornonary sinus has been shown to be efficacious in converting atrial fibrillation to sinus rhythm. We report the successful use of this technology in an implantable form in a patient with symptomatic atrial fibrillation. The patient could be kept in sinus rhythm using an implanted atrial defibrillator.

Atrial Fibrillation↗

Ventricular tachycardia in valvular heart disease: facilitation of sustained bundle-branch reentry by valve surgery.

BACKGROUND: The clinical characteristics of sustained monomorphic ventricular tachycardia (SMVT), when it develops after valve surgery, have not been described. METHODS AND RESULTS: Between 1985 and 1996, 31 patients (30 men and 1 woman) who had undergone valve surgery were found to have inducible SMVT. Nine patients (29%) had sustained VT due to bundle-branch reentry (BBR) (group 1). Four of these patients had normal left ventricular function, and VT with a right bundle-branch morphology was inducible in 4 patients. Group 2 included 20 patients with inducible myocardial (ie, non-BBR) VT. Coronary artery disease was present in 15 group 2 patients (75%) due to atherosclerotic (n=12) and nonatherosclerotic (n=3) causes. Two patients had both inducible sustained BBR and myocardial VT (group 3). Sustained BBR VT occurred significantly earlier after valve surgery (median, 10 days) than the onset of postoperative myocardial VT (median, 72 months; P<.005). CONCLUSIONS: Myocardial VT was the most common type of inducible SMVT in patients with valvular heart disease. The majority of these patients had underlying coronary artery disease and significant left ventricular dysfunction. However, in almost one third of the patients, sustained BBR VT was the only type of inducible SMVT. This type of VT was facilitated by the valve procedure occurring within 4 weeks after surgery in most patients. In these patients, left ventricular function was relatively well preserved, and the right bundle-branch block type of BBR was frequently induced. Because a curative therapy can be offered to these patients (ie, bundle-branch ablation), BBR should be seriously considered as the mechanism of VT in patients with valvular heart disease, particularly if the arrhythmia occurs soon after valve surgery.

Adult↗

Comparison of outcome of implantable cardioverter defibrillator implantation in patients with severe versus moderately severe left ventricular dysfunction secondary to atherosclerotic coronary artery disease.

This study was undertaken to assess the feasibility and clinical outcome of implantable cardioverter-defibrillators (ICDs) among patients with coronary artery disease and left ventricular ejection fraction (LVEF) of <20%. The morbidity, mortality, and the long-term survival of 117 patients with LVEF of <20% (group 1) were compared with 321 patients with LVEF of 20% to 40% (group 2). Mortality in the first 30 days after ICD implantation was 0% for group 1 and 0.6% in group 2. Actuarial survival (all cause) at the end of 2, 4, and 5 years were 83%, 70%, and 62%, respectively, in group 1 and 90%, 80%, and 71% in group 2 (p = 0.05). Fifty-five patients (47%) in group 1 and 126 patients (39%) in group 2 received appropriate shocks during follow up. Among the patients in group 1, the overall survival at 2 years after an appropriate shock from an ICD was 92% for patients <60 years of age, 77% for patients ages 60 to 69, and 53% for patients >70 years old. Although the overall survival of patients in group 1 was slightly lower compared with those in group 2, in a multivariate analysis, the EF was not an independent predictor of poor survival. The ICD can be implanted with acceptable operative morbidity and mortality in selected patients with LVEF of <20%.

Aged↗

Efficacy of the implantable cardioverter-defibrillator in the elderly.

OBJECTIVES: We sought to assess the effect of advanced age on the outcome of patients with an implantable cardioverter-defibrillator (ICD). BACKGROUND: ICDs are effective in preventing sudden cardiac death in susceptible patients, but their beneficial effect on survival is attenuated by the high rate of nonsudden cardiac death in those treated. Although advanced age is an important variable in determining cardiovascular mortality, its impact on the outcome of patients with an ICD has been inadequately studied. METHODS: We performed multivariate analysis of a data base consisting of 769 consecutive patients with an ICD. Seventy-four patients > or = 75 years old at ICD implantation (Group 1) were compared with the remaining 695 patients (Group 2). RESULTS: The two groups were similar in clinical presentation, left ventricular function and gender distribution. The mean follow-up time was 29 and 42 months, respectively, for patients in Group 1 and Group 2. Actuarial survival at 4 years was 57% in Group 1 versus 78% in Group 2 (p = 0.0001). This difference was primarily due to a higher rate of nonsudden cardiac death in Group 1. On multivariate analysis, age > or = 75 years, New York Heart Association functional class III, left ventricular ejection fraction < 30% and appropriate shocks during follow-up were independently associated with increased mortality (odds ratio 3.56, 1.8, 1.6 and 1.39, respectively). CONCLUSIONS: Among patients with similar functional class and ejection fraction, the mortality risk is increased threefold in those > or = 75 years old at the time of ICD implantation. Extrapolation of results from younger patients is likely to overestimate ICD benefit in the elderly.

Age Factors↗

Specificity of head-up tilt testing in adolescents: effect of various degrees of tilt challenge in normal control subjects.

OBJECTIVES: This study sought to determine the specificity of commonly used tilt protocols in children. BACKGROUND: Tilt table testing is commonly utilized in the evaluation of children and adolescents with syncope despite a lack of uniformity in tilt protocols and a lack of studies of specificity in normal control subjects. METHODS: Sixty-nine normal control volunteers (12 to 18 years old, 38 male, 31 female) with no previous history of syncope, presyncope or arrhythmia underwent tilting to 80 degrees, 70 degrees or 60 degrees for a maximum of 30 min on a motorized table with a footboard support. Autonomic maneuvers, including deep breathing, carotid massage, Valsalva maneuver and diving reflex, were performed before tilt testing to determine whether the response to these maneuvers could identify subjects prone to fainting during tilt testing. RESULTS: Symptoms of presyncope and frank syncope were elicited in 24 of 69 subjects (13 male, 11 female): 6 (60%) of 10 were tilted at 80 degrees, 9 (29%) of 31 at 70 degrees and 9 (32%) of 28 at 60 degrees. Tilt testing at 80 degrees was terminated after the tenth subject by the institutional review board. The mean time to a positive test response was 10.5 min at 80 degrees, 14.2 min at 70 degrees and 13.2 min at 60 degrees. In the 80 degrees tilt, 4 of 10 subjects had a positive response within 10 minutes, whereas only 3 of 31 and 2 of 28 had a positive response within < 10 min at 70 degrees and 60 degrees tilt angles, respectively. Subjects with and without a positive response to tilt testing were similar with respect to age; gender; PR, QRS and QT intervals; and baseline heart rate and blood pressure. Likewise, responses to other autonomic function tests performed were similar in tilt-positive and tilt-negative patients. The power for detecting a significant difference between patients tilted at 80 degrees versus 60 degrees and 70 degrees was 0.45 and for detecting differences in autonomic tone between tilt-positive (n = 24) and tilt-negative (n = 45) subjects was 0.8. CONCLUSIONS: Children appear to be more susceptible to orthostatic stress than adults. Therefore, tilt protocols commonly used in adults lack specificity in teenage patients. A specificity > 85% may be obtained by performing the tilt test at 60 degrees or 70 degrees for no longer than 10 min.

Adolescent↗

The effect of biphasic waveform tilt in transvenous atrial defibrillation.

Atrial defibrillation can be accomplished using low energy shocks and transvenous catheters. The biphasic waveform tilt required to achieve optimal atrial defibrillation thresholds (ADFTs) is, however, not known. The effect of single capacitor biphasic waveform tilt modification on ADFT was assessed in 20 patients. Following AF induction the defibrillation pulses were delivered between the catheters positioned in the coronary sinus and the right atrium. The single capacitor biphasic waveform shocks, delivered over the same pathways, consisted of 65% tilt (65/65 biphasic waveform) to produce an overall tilt of 88%, or 50% tilt (50/50 biphasic waveform) to produce an overall tilt of 75%. Although 65/65 biphasic waveform delivers more energy, the shorter duration 50/50 biphasic waveform reduced stored energy ADFT 21%, from 1.34 +/- 0.82 J with 65/65 biphasic to 1.06 +/- 0.81 J. These differences were not statistically significant. Nine patients had lower ADFT with 50/50 biphasic waveform while five patients had lower ADFT with 65/65 biphasic waveform. Equivalent reduction in ADFT was seen in the remaining six patients. The ADFT was 0.83 +/- 0.65 J when both tilts were considered. In conclusion, biphasic waveform tilt modification may affect the ADFT in an individual patient. The optimal biphasic waveform for ADFT is not known.

Adult↗

The effect of polarity of the initial phase of a biphasic shock waveform on the defibrillation threshold of pectorally implanted defibrillators.

The effect of initial phase polarity on the DFT of two pectorally implanted biphasic ICDs was tested in a randomized, prospective manner at the time of implantation. Twenty-two consecutive patients with VT-VF who received either the Medtronic PCD 7219C Jewel device (10 patients) or PCD 7219D Jewel device (12 patients) were studied. DFT testing was performed in a standard step-down manner. Both initial phase polarities--initial defibrillation current flowing from active can/SVC coil +/- subcutaneous patch) to the RV coil (RV coil to active can/SVC (RV+)--were tested in random order. The mean DFT achieved with RV+ compared with RV-was lower for the 7219C patient group (6.6 +/- 3.1 vs 10.8 +/- 5.5 J; P = 0.007). A similar trend was observed for the 7219D group, though the difference did not reach statistical significance (12.0 +/ 4.0 vs 16.3 +/- 7.3 J; P = 0.07). Seven of the 10 patients in the 7219C group had a lower DFT with RV+, while the initial phase polarity made no difference in 3. In the 7219D group, 7 patients had a lower DFT using RV+, 2 patients had a lower DFT using RV-, and the initial phase polarity made no difference in 3. In conclusion, this study demonstrates that changing the polarity of the initial phase of a biphasic shock waveform can have a significant impact on the DFT achieved at the time of ICD implantation.

Aged↗

Efficacy of midodrine hydrochloride in neurocardiogenic syncope refractory to standard therapy.

INTRODUCTION: Some patients with neurocardiogenic syncope continue to have recurrent syncope or presyncope despite the use of currently available drug therapy. The purpose of this study was to determine whether midodrine hydrochloride, a selective adrenergic agonist, could be effective in patients resistant to, or intolerant of, currently used medications in the treatment of neurocardiogenic syncope. METHODS AND RESULTS: Eleven patients with a history of recurrent syncope or presyncope in whom hypotension with syncope or presyncope could be provoked during head-up tilt testing were included. There were 4 men and 7 women with a mean age (+/-SD) age of 34 +/- 13 years. In all patients, standard therapy with beta-adrenergic receptor blocking agents, ephedrine, theophylline, disopyramide, fludrocortisone, and sertraline hydrochloride, was either ineffective, poorly tolerated, or contraindicated. Midodrine was initially administered orally at a dose of 2.5 mg three times daily. After adjustment of dosage over 2 to 4 weeks, patients were followed-up clinically. Midodrine was discontinued in one patient because of side effects. Frequency of syncope or presyncope during the 3 months prior to starting treatment was compared during a mean follow-up of 17 +/- 4 weeks after starting treatment with midodrine. There was significant (P < 0.01) reduction in syncopal and presyncopal episodes on midodrine. Five patients had complete resolution of symptoms, while four patients had significant improvement. Symptoms did not improve in one patient. CONCLUSIONS: Midodrine hydrochloride can be effective in preventing recurrent symptoms in selected patients with neurocardiogenic syncope unresponsive to, or intolerant of, standard drug therapy.

Administration, Oral↗

Delivery of noncommitted shocks for nonsustained ventricular arrhythmias by a new implantable cardioverter defibrillator with abortive shock capability.

INTRODUCTION: To describe the delivery of noncommitted implantable cardioverter defibrillator (ICD) shocks despite self-termination of ventricular arrhythmias. Abortive shock capability should eliminate the delivery of shocks for self-terminating ventricular arrhythmias. The delivery of noncommitted shocks despite abortive shock capability is, therefore, unexpected and previously unreported. METHODS AND RESULTS: Among 118 patients who received the Transvene nonthoracotomy lead system and the Jewel ICD (model 7219D), three patients (1.7%) experienced supurious, noncommitted shocks for self-terminating arrhythmias. Only one detection zone (i.e., ventricular fibrillation) had been programmed in the defibrillator in each patient. In all three patients, the ventricular arrhythmias self-terminated during the charging period. One patient received seven shocks during periods of asystole, and the other two patients received one shock each. Two different mechanisms for shock delivery in this setting were identified: one occurring in the absence of electrical activity at the end of the bradycardia escape interval (i.e., associated with bradyarrhythmias), and the other when two sensed electrical events (i.e., escape beats) occurred during the so-called "synchronization" window of the defibrillator. CONCLUSIONS: In rare patients with the Jewel defibrillator, shocks may be delivered for self-terminating arrhythmias despite abortive shock capability. Patients who are dependent upon pacing from their implanted defibrillator are at particular risk for shock in the aftermath of self-terminating ventricular arrhythmias. Defibrillator programming strategies aimed at eliminating or diminishing the incidence of this problem are discussed.

Aged↗

Feasibility of atrial fibrillation detection and use of a preceding synchronization interval as a criterion for shock delivery in humans with atrial fibrillation.

OBJECTIVES: This study assessed the feasibility of detecting atrial fibrillation (AF) and delivery of appropriately timed R wave shocks using an implantable atrial defibrillator. BACKGROUND: For atrial defibrillation therapy to be feasible in an implantable form, AF must be detected in a specific fashion, and the risk of ventricular proarrhythmia should be minimized. METHODS: Eleven patients with AF underwent testing with an implantable atrial defibrillator (METRIX 3000 Automatic Atrial Defibrillator, InControl, Inc.). Wideband electrograms (EGMs) were recorded from the right ventricular (RV) bipolar catheter and from the multipolar catheters located in the right atrium (RA) and coronary sinus (CS). Atrial fibrillation detection was performed using two serial algorithms-quiet interval analysis and baseline crossing analysis-that detect atrial activity on the RA-CS channel. Ventricular sensing using a minimal preceding synchronization interval of 500 ms as a criterion for synchronous shock delivery was performed from filtered RV and RV-CS EGMs. RESULTS: The AF detection algorithms were applied to 53 AF data segments and 18 normal sinus rhythm data segments. Atrial fibrillation was detected appropriately in 49 instances, and the specificity for detecting AF and normal sinus rhythm was 100%. Synchronization criterion efficacy was assessed by delivering shock markers and shocks. Of the 2,025 R waves processed, 557 (27.5%) were marked as suitable for shock delivery. In addition, 69 therapeutic and 11 test shocks were delivered during AF. All shock markers and shocks were delivered synchronously with the R wave, and the synchronization criterion was never violated. CONCLUSIONS: Atrial fibrillation can be detected in a specific fashion using the RA-CS lead configuration and serial detection algorithms for atrial sensing. The delivery of properly timed shocks is feasible and should minimize the risk of ventricular proarrhythmia.

Adult↗

Recurrence of neurocardiogenic syncope without pharmacologic interventions.

In 54 patients with positive tilt and who refused medical therapy, we observed a significant decrease in the frequency of syncopal spells after diagnosis and counseling. However, symptoms were reported at follow-up by 64.8% of the patients and were predicted by the frequency and total number of syncope episodes before upright tilt.

Adult↗

Unmasking the trifascicular left intraventricular conduction system by ablation of the right bundle branch.

Twenty-five patients underwent transcatheter right bundle ablation either for bundle branch reentrant tachycardias or inadvertent or deliberate right bundle ablation during atrioventricular junctional ablation for rate control. Electrophysiologic data and 12-lead electrocardiograms before and after right bundle ablation were available in all patients. Eleven of the patients had no significant intraventricular conduction abnormalities by surface electrocardiograms (group I), whereas 14 patients had underlying intraventricular conduction delays (group II). All group I patients had typical electrocardiographic changes of right bundle branch block after right bundle ablation, with minimal changes in initial or mean QRS axis. In group II, 5 patients had an initial 40 ms QRS axis shift of > 45 degrees, in 7 patients the mean QRS axis changed significantly (leftward in 4 and rightward in 3), and a qR pattern in V1 was seen in 12 of 14 patients including 2 with structurally normal hearts. These changes, namely new Q waves, and rightward and leftward axis shifts are most likely the result of septal fascicular, left posterior fascicular, and left anterior fascicular delay/block, which were exposed by exclusive conduction via a diseased left bundle and its fascicles. The trifascicular nature of left intraventricular conduction is more apparent when diseased and unmasked by concomitant block in the right bundle branch.

Aged↗

Distribution of atrial electrogram types during atrial fibrillation: effect of rapid atrial pacing and intercaval junction ablation.

OBJECTIVES: This study examined the anatomic distribution types and possible determinant of atrial electrogram types during atrial fibrillation. BACKGROUND: Different types of atrial electrograms during atrial fibrillation have been observed and classified, but their anatomic distribution patterns, determinants and potential usefulness in guiding future catheter ablation are unknown. METHODS: Two animal models of atrial fibrillation were used: the sterile pericarditis model (n = 10) and the rapid atrial pacing model (400 beats/min for 6 weeks, n = 6). The atrial electrogram of atrial fibrillation and the atrial effective refractory period were obtained from multiple sites of the right and left atrium. In addition, decremental rapid atrial stimulation was applied to the site of shortest and longest atrial effective refractory periods until atrial fibrillation induction in a subgroup of nine dogs. Ablation of the intercaval junction was performed using the radiofrequency catheter technique in dogs with atrial fibrillation duration > 1 min. RESULTS: In both models, organized atrial electrograms (type I) were predominantly observed at the left atrial sites and the right atrial appendage, whereas disorganized atrial electrograms (type III) were mainly observed at the right posterolateral atrium. The distribution of the atrial electrogram types closely followed that of the atrial effective refractory period, with the shortest atrial effective refractory period corresponding to organized atrial electrograms (type I) and the longest atrial effective refractory period corresponding to disorganized atrial electrograms (type III). The correlation of atrial electrogram type with the atrial effective refractory period was further demonstrated by the effect of rapid atrial stimulation. When rapid atrial stimulation was applied to the site with the shortest atrial effective refractory period, disorganized atrial electrograms were observed at sites with the longest atrial effective refractory period, whereas 1:1 atrial capture was still present at the stimulation site. Ablation of the intercaval junction made atrial fibrillation noninducible or tended to shorten the atrial fibrillation duration (from 26.4 +/- 24.2 to 8.8 +/- 22.6 min in the pericarditis group, p = 0.02, and from 33.7 +/- 29.2 to 12.1 +/- 23.8 min in the rapid pacing group, p = 0.09) but did not change the atrial electrogram types during atrial fibrillation. CONCLUSIONS: Various types of atrial electrograms are present at different locations during atrial fibrillation. The atrial electrogram characteristics of atrial fibrillation at a specific location are related to the atrial effective refractory period, with short effective refractory periods associated with organized atrial electrograms and long effective refractory periods associated with disorganized electrograms.

Animals↗