Caffeine citrate for the treatment of apnea of prematurity: a double-blind, placebo-controlled study.

STUDY OBJECTIVE: To evaluate the efficacy and safety of caffeine citrate for treatment of apnea of prematurity. DESIGN: Multicenter, parallel, randomized, double-blind, placebo-controlled trial with open-label rescue. SETTING: Nine neonatal intensive care units. PATIENTS: Eighty-five infants, 28-32 weeks postconception and 24 hours or more after birth who had six or more apnea episodes within 24 hours. INTERVENTION: Caffeine citrate 10 mg/kg (as caffeine base) administered intravenously, followed by 2.5 mg/kg/day orally or intravenously, or placebo, for up to 10 days. Infants failing double-blind therapy could receive open-label rescue. MEASUREMENTS AND MAIN RESULTS: Success was defined as 50% or greater reduction in apnea episodes and elimination of apnea. Caffeine citrate was significantly more effective than placebo in reducing apnea episodes by at least 50% in 6 days (p<0.05), and approached statistical significance (p<0.10) in 3 days. It was significantly better than placebo in eliminating apnea in 5 days (p<0.05), and approached significance (p<0.10) in 2 days. The number of infants with an aggregate of 7-10 days of at least a 50% reduction in apnea events or elimination of apnea was significantly higher in the caffeine citrate than in the placebo group. Adverse events did not differ significantly between groups. No correlations were found between success and mean daily plasma concentrations or baseline characteristics. Volume of distribution and clearance increased with weight, supporting weight-adjusted dosing of caffeine citrate. CONCLUSION: Caffeine citrate 10 mg/kg caffeine base (equivalent to 20 mg/kg caffeine citrate) intravenously followed by 2.5 mg/kg/day caffeine base (equivalent to 5 mg/kg/day caffeine citrate) either intravenously or orally for 10 days is safe and effective for treating apnea of prematurity in infants 28-32 weeks postconception.

Apnea↗

Novel somatostatin analogs for the treatment of acromegaly and cancer exhibit improved in vivo stability and distribution.

The biodistribution of several radiolabeled somatostatin (SRIF) analogs was determined in the rat. Newly developed analogs BIM-23190 and BIM-23197 attained higher plasma levels and much greater target tissue concentrations than the clinically used BIM-23014 analog. Highest tissue concentrations of BIM-23190 and BIM-23197 were found in adrenal, kidney, pituitary and pancreas, tissues that are known to be abundant in mRNA for the somatostatin subtype 2 receptor. BIM-23190 and BIM-23197 associated radioactivity in these tissues was prolonged compared with that of BIM-23014, especially in the SRIF-receptor-rich pituitary. BIM-23190 and BIM-23197 were more stable in vivo and much less subject to biliary excretion than BIM-23014. These properties account for the elevated plasma and target tissue concentrations of these new SRIF analogs. Based on higher plasma levels, greater distribution to target tissues and longer in vivo stability, BIM-23190 and BIM-23197 may prove to be superior to BIM-23014 for the treatment of acromegaly and some types of cancer.

Acromegaly↗

Imaging evaluation of breast-feeding and bottle-feeding systems.

OBJECTIVE: To compare infant sucking and swallowing patterns during feeding with a new artificial nipple and during breast-feeding. METHODS: Fifteen healthy, term infants were fed successfully for 1 week with use of the new tricut nipple; then each infant's oral cavity was examined during feeding by using real-time ultrasonography. Measurements of nipple length and compression were made, together with observations concerning the integrity of the seal formed by the infant's mouth around the nipple. These data were compared with similar data from previous studies of 16 breast-fed infants. RESULTS: Although no artificial feeding system exactly simulates breast-feeding, the new tricut nipple was sucked in a manner similar to the way the human nipple is sucked and delivered milk posteriorly to the foramen cecum region of the tongue, just as the breast does. CONCLUSION: Although further studies are necessary, to evaluate other characteristics of the new tricut nipple, the measurements from this investigation are useful additions to the ultrasound data these investigators have accumulated on various artificial feeding systems. These data may also prove helpful in determining the most appropriate nipples for infants with various feeding disorders.

Bottle Feeding↗

Imaging evaluation of artificial nipples during bottle feeding.

OBJECTIVES: To determine whether real-time ultrasonography can be used to directly visualize artificial nipples in vivo while an infant is sucking, to compare deformation differences of the artificial nipple with the human nipple during sucking, and to compare the suck mechanism used by the infant with four types of artificial nipples. DESIGN: Nonrandomized clinical study with a control group. SETTING: University-affiliated teaching hospital in Iowa City, Iowa. PARTICIPANTS: A volunteer sample of 35 healthy infants 6 to 12 weeks of age. INTERVENTION: None. MEASUREMENTS/MAIN RESULTS: Images produced by real-time ultrasound of infants during sucking using artificial nipples were measured to determine the percentage lengthening, the percentage lateral compression, and the percentage flattening of nipples. These results were compared with data obtained from studies using breast-fed infants. None of the artificial nipples lengthened like the human nipple. One artificial nipple was significantly more compressible than the human nipple and the remaining three artificial nipples. CONCLUSION: Real-time ultrasonography can be used to visualize artificial nipples in vivo during sucking.

Bottle Feeding↗

Safety and efficacy of sufentanil therapy in the ventilated infant.

This pilot study examined the safety and efficacy of sufentanil in the ventilated neonate. Informed parental consent for study participation was obtained for eight infants who were admitted to the neonatal intensive care unit and required analgesic/sedative therapy as part of their medical management to support mechanical ventilation. An intravenous loading dose (0.2 microgram/kg) was administered over 20 minutes, followed by a continuous infusion (0.05 microgram/kg/hour). Whole blood samples were collected prior to onset of sufentanil therapy, immediately following the loading dose, and 24 hours after the start of the continuous sufentanil infusion for analysis of beta-endorphin and sufentanil serum content. Heart rate, respiratory rate, and blood pressure were recorded as a routine part of medical management. The ventilatory efficiency index (VEI) and ventilation index (VI) were calculated before and after sufentanil therapy. Four male and four female infants were admitted to this study; the mean gestational age was 37 weeks, and weight was 2,970 gm. Sufentanil therapy appeared to be well tolerated, as evidenced by a lack of nursing observations noting changes in heart rate or mean arterial pressure. VEI values increased in four subjects, and VI values decreased in six subjects. Overall, the mean increase in VEI was 19 percent; the decrease in VI was 27 percent. The beta-endorphin serum content decreased in all subjects, and nurses did not report any signs of patient discomfort. Serum sufentanil content was undetectable. Sufentanil appears to be a suitable agent to provide analgesia/sedation in the neonatal patient under the experimental conditions of this study.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Pressure↗

Continuous intravenous morphine infusion in postoperative newborn infants.

The efficacy and safety of morphine sulfate was evaluated in 20 neonates requiring surgery. Following surgery, each subject received an intravenous morphine loading dose (50 micrograms/kg) followed by a continuous infusion (15 micrograms/kg/hr) for a minimum of 24 hours. Heart rate, respiratory rate, and blood pressure were frequently monitored during therapy. Blood samples were obtained following surgery and during and after morphine therapy for analysis of serum morphine and beta-endorphin content. A 12-hour urine collection was obtained 12 hours following the start of the constant morphine infusion for analysis of morphine content. The mean (+/- SD) duration of morphine infusion was 34 +/- 15 hours and a steady-rate serum morphine concentration was 39 +/- 23 ng/ml. The respective serum morphine half-life, elimination rate, and volume of distribution were 6.6 +/- 2.9 hr, 0.126 +/- 0.056 hr-1, and 5.0 +/- 6.8 liters/kg. The mean percentage of unchanged morphine recovered in the urine was 39 +/- 19 of the dose administered over 12 hours. A significant reduction in serum beta-endorphin content was observed following the onset of morphine therapy. No adverse reports were noted that could be attributed to morphine therapy. Continuous morphine therapy appears to be effective in controlling neonatal postoperative pain, as suggested by subjective nursing observations and decreased serum beta-endorphin content.

Analgesia↗

Safety and efficacy of a topical anesthetic for neonatal circumcision.

OBJECTIVE: Circumcision is a common neonatal surgical procedure routinely performed without the use of anesthesia. The purpose of this study was to evaluate the safety and efficacy of topical lidocaine cream as an anesthetic for circumcision. METHODS: Thirty newborns were studied in a randomized, double-blind, placebo-controlled study; 15 received a topical 30% lidocaine cream and 15 received the cream base alone. Vital signs were recorded, and preoperative and postoperative serum beta-endorphin and lidocaine concentrations were measured. A videotape of the newborn was used to score behavioral changes. RESULTS: Comparisons of the vital signs precircumcision and postcircumcision showed no differences between the placebo and treatment groups, with the exception of mean systolic blood pressure, which significantly increased in the placebo-treated newborns (P < .05). Serum beta-endorphin concentrations increased postoperatively in 11 of 15 subjects receiving placebo, but decreased or remained unchanged in 10 of 15 subjects receiving lidocaine (P = .03, Fisher's exact test). When stress-related behaviors in the precircumcision and post-circumcision periods were compared, the mean increase in their occurrence was greater in the placebo than in the treatment group. There was no significant absorption of lidocaine as measured in the serum. CONCLUSION: Topical application of a 30% lidocaine cream as used in this study may be a safe and efficacious anesthetic for circumcision.

Anesthesia, Local↗

Influence of infusion pumps on the pharmacologic response to nitroprusside.

OBJECTIVE: To compare the relationship between variability in nitroprusside delivery from five infusion pumps and the resulting variability in mean arterial pressure (MAP). DESIGN: Randomized, crossover study design. SETTING: A pediatric ICU in a university hospital. PATIENTS: Informed parental consent was obtained for six patients who were hemodynamically stable and receiving a continuous nitroprusside infusion for a clinical application. Subjects ranged in age from 11 months to 9 yr. INTERVENTIONS: All of the subjects were administered nitroprusside using selected infusion pumps, which included Abbott (Micro), 3M/AVI (210), IMED (965), IVAC (565), and Kendall McGaw (MicroRate). MEASUREMENTS AND MAIN RESULTS: After an initial equilibration interval for each device, MAP was measured and recorded at 10-sec intervals for greater than or equal to 90-min intervals using a computerized data collection technique. Variation in nitroprusside administration (flow continuity) for each infusion pump was determined in vitro using a computerized gravimetric technique. Variation in both MAP and flow continuity was mathematically expressed as the coefficient of variance (CV) of the measured values for each of the respective infusion pumps. For the Abbott, IMED, 3M/AVI, IVAC, and Kendall McGaw, infusion pumps, mean +/- SD continuity CV values were 85 +/- 31%, 39 +/- 26%, 19 +/- 8%, 17 +/- 3%, and 12 +/- 3%, respectively, and MAP CV values were 18 +/- 21%, 15 +/- 11%, 8 +/- 2%, and 16 +/- 10%, respectively. CONCLUSIONS: An apparent direct relationship between MAP variability and flow continuity was observed. We speculate that variation in effect of potent short-acting drugs may, in part, be due to infusion pump operation.

Blood Pressure↗

Pulmonary mechanics in healthy term neonates: variability in measurements obtained with a computerized system.

Using a commercially available computer-based analysis of ventilation and esophageal pressure (PeDs), we studied 11 healthy term neonates with serial pulmonary mechanics measurements during the first 3 days of life to determine the intrasubject variability of repeated measurements. Three consecutive pulmonary function tests were obtained before and after repositioning of the esophageal catheter, for a total of six measurements per day in each subject. The daily coefficient of variation for these 11 subjects ranged from 6% to 32% for respiratory rate; 6% to 27% for tidal volume; 3% to 28% for specific dynamic compliance, and 11% to 69% for pulmonary resistance. Repositioning the esophageal catheter did not produce significant differences in measurements of pulmonary mechanics (p greater than 0.05). We conclude that within a given subject, the maximum variability (mean + 2 SD) was 28% for specific dynamic compliance and 56% for pulmonary resistance. These intrasubject variability limits are important when one is interpreting pulmonary mechanics measurements in neonates before and after specific treatment, such as bronchodilators, diuretics, surfactant, or steroids.

Airway Resistance↗

Decreased flow accuracy from volumetric infusion pumps.

Accurate flow from infusion pumps should be maintained when exposed to a variety of clinical conditions. The intent of this study was to evaluate in vitro flow rate accuracy of three infusion pumps subjected to the influences of variable back-pressure, solution viscosity, and infusion rates. A factorial study design was selected to determine the influence of three flow rates (5, 10, and 20 ml/h), three back-pressures (100, 200, and 300 mm Hg), and two solution viscosities (5%, 25% dextrose in water) on flow rate accuracy from three infusion pumps (Abbott 4P, IVAC 560, and Travenol 6200) using a standard gravimetric technique. Mean +/- SD accuracy values were -9.4 +/- 6.4% (range -29.1 to -0.7), 0.5 +/- 2.2% (range -4.2 to 6.3), and -0.5 +/- 4.7% (range -8.5 to 9.9) of the desired rate for the Abbott, IVAC, and Travenol devices, respectively. Back-pressure was the only factor to influence significantly flow accuracy for the Abbott device (r = .81). All factors significantly influenced accuracy for the Travenol device (r = .55). No factor influenced accuracy for the IVAC infusion pump. Both the IVAC 560 and Travenol 6200 have acceptable flow accuracy values within the range of study factors examined. The Abbott 4P had significant decreases in flow accuracy in response to increasing back-pressure.

Calibration↗

Imaging evaluation of the human nipple during breast-feeding.

A new real-time ultrasound technique was employed to document in vivo the anatomic characteristics of the human nipple during breast-feeding. The study quantifies human nipple deformation and provides a description of the mechanics of normal sucking derived from 16 normal infants aged 60 to 120 days. This in vivo imaging technique has great potential value in the study of feeding dysfunction.

Adult↗

Flow rate variability from electronic infusion devices.

During continuous drug administration to pediatric patients, unfavorable pharmacologic effects have occurred. These effects were attributed to variations in flow from electronic infusion devices (EIDs). The intent of this investigation was to evaluate the influence of microrate (0.1 to 99.9 ml/h) EID on the accuracy, continuity, and pattern of flow of continuously effused fluid. Using a factorial study design, iv fluid was effused through iv delivery systems using combinations of five microrate EIDs, three iv flow rates, and three sample-collection intervals. Serial weights were measured at the appropriate sample-collection time using a computerized gravimetric technique to determine accuracy, continuity, and pattern of flow. All the EIDs produced accurate flow within 5% of the desired rate of 5 and 10 ml/h. At 1 ml/h, the actual iv flow rate ranged from 65.1% to 91% of the desired rate. Each of the respective EIDs produced various levels of flow continuity; each flow pattern characterized the mechanism of pump operation for each device. Thus, alteration in response (e.g., increased toxicity or decreased efficacy) to a continuous drug infusion must not be attributed exclusively to the drug or clinical condition of the patient. Serious consideration should also be given to the method of drug delivery and, in particular, the continuity of flow that results from a particular EID.

Child↗

Changes in arterial blood gases following cardiac asystole during fetal life.

A case of suspected fetal cardiac asystole with normal umbilical cord blood gas values is reported. Possible explanations of this apparent discrepancy were examined by measuring sequential changes in fetal arterial acid-base and blood gas values after induced cardiac asystole in chronically instrumented fetal lambs at 132-141 days' gestation. Arterial pH values did not decrease from baseline for at least ten minutes. Elevation of pCO2 values were observed at 30 minutes. Arterial pO2 and HCO3 values remained unchanged for at least 30 minutes. Therefore, we conclude that sudden fetal cardiac asystole occurring within ten minutes of delivery may be one reason why umbilical cord acid-base and blood gas values do not correlate with Apgar scores.

Acid-Base Equilibrium↗