PubMed Health⌕ Search

Biomedical subjects

A Erfanian

Publications and source records attributed to A Erfanian.

2 recordsLinked to original sources

Real-time ocular artifact suppression using recurrent neural network for electro-encephalogram based brain-computer interface.

The paper presents an adaptive noise canceller (ANC) filter using an artificial neural network for real-time removal of electro-oculogram (EOG) interference from electro-encephalogram (EEG) signals. Conventional ANC filters are based on linear models of interference. Such linear models provide poorer prediction for biomedical signals. In this work, a recurrent neural network was employed for modelling the interference signals. The eye movement and eye blink artifacts were recorded by the placing of an electrode on the forehead above the left eye and an electrode on the left temple. The reference signal was then generated by the data collected from the forehead electrode being added to data recorded from the temple electrode. The reference signal was also contaminated by the EEG. To reduce the EEG interference, the reference signal was first low-pass filtered by a moving averaged filter and then applied to the ANC. Matlab Simulink was used for real-time data acquisition, filtering and ocular artifact suppression. Simulation results show the validity and effectiveness of the technique with different signal-to-noise ratios (SNRs) of the primary signal. On average, a significant improvement in SNR up to 27 dB was achieved with the recurrent neural network. The results from real data demonstrate that the proposed scheme removes ocular artifacts from contaminated EEG signals and is suitable for real-time and short-time EEG recordings.

Artifacts↗

Using evoked EMG as a synthetic force sensor of isometric electrically stimulated muscle.

A method for the estimation of the force generated by electrically stimulated muscle during isometric contraction is developed here. It is based upon measurements of the evoked electromyogram (EMG) [EEMG] signal. Muscle stimulation is provided to the quadriceps muscle of a paralyzed human subject using percutaneous intramuscular electrodes, and EEMG signals are collected using surface electrodes. Through the use of novel signal acquisition and processing techniques, as well as a mathematical model that reflects both the excitation and activation phenomena involved in isometric muscle force generation, accurate prediction of stimulated muscle forces is obtained for large time horizons. This approach yields synthetic muscle force estimates for both unfatigued and fatigued states of the stimulated muscle. In addition, a method is developed that accomplishes automatic recalibration of the model to account for day-to-day changes in pickup electrode mounting as well as other factors contributing to EEMG gain variations. It is demonstrated that the use of the measured EEMG as the input to a predictive model of muscle torque generation is superior to the use of the electrical stimulation signal as the model input. This is because the measured EEMG signal captures all of the neural excitation, whereas stimulation-to-torque models only reflect that portion of the neural excitation that results directly from stimulation. The time-varying properties of the excitation process cannot be captured by existing stimulation-to-torque models, but they are tracked by the EEMG-to-torque models that are developed here. This work represents a promising approach to the real-time estimation of stimulated muscle force in functional neuromuscular stimulation applications.

Artifacts↗