PubMed Health⌕ Search

Biomedical subjects

A F Abramson

Publications and source records attributed to A F Abramson.

42 records · Page 3Linked to original sources

Stereotaxic 14-gauge breast biopsy: how many core biopsy specimens are needed?

PURPOSE: To determine the optimum number of specimens to obtain at stereotaxic core breast biopsy. MATERIALS AND METHODS: Stereotaxic biopsies were performed in 145 mammographically evident lesions by using a dedicated table with patients in the prone position. Samples were obtained with an automated gun and a 14-gauge needle. Indications for biopsy were calcifications (n = 53) and masses (n = 92). Three to 11 (mean, 5.4) core biopsy specimens were obtained per lesion and were analyzed separately. RESULTS: Diagnostic material was obtained in the first specimen in 102 (70%) of the 145 lesions. Obtaining two, three, four, five, and six core specimens yielded a diagnosis in 117 (81%), 129 (89%), 132 (91%), 137 (94%), and 140 (97%) of the 145 lesions, respectively. Obtaining five specimens yielded a diagnosis in 46 (87%) of the 53 calcifications and 91 (99%) of the 92 masses. Obtaining six specimens resulted in a diagnosis in 49 (92%) lesions evident as calcifications but did not improve the yield on masses. CONCLUSION: Stereotaxic 14-gauge core biopsy achieved a 99% diagnostic yield with five specimens for masses. Additional specimens may be necessary to diagnose some calcified lesions.

Biopsy, Needle↗

Use of digital mammography in needle localization procedures.

OBJECTIVE: With digital technology, images can be displayed rapidly and manipulated. This study was undertaken to assess the duration and accuracy of needle localizations performed with digital vs film-screen technology. These two technologies also were compared with respect to radiation doses and ability to image a standard phantom. SUBJECTS AND METHODS: A prototype digital mammographic system with both a 512 x 512 matrix and a 1024 x 1024 matrix was evaluated by using the American College of Radiology mammography accreditation phantom, and these results were compared with testing done on commercially available, dedicated, analog mammography equipment. Duration, accuracy of needle placement, and number of exposures needed to perform localization were recorded for 157 consecutive needle localizations done with digital technology, and these results were compared with data collected from 103 needle localizations done with film-screen technology. Another 33 localizations attempted with digital imaging were aborted because of technical factors. Average glandular doses were calculated for those women who had a compressed breast thickness of 4-5 cm. RESULTS: The time to complete needle localization was reduced by almost 50%, from 20 to 11 min, when digital technology was used. Because of the small (5 x 5 cm) field of view of the digital system, an additional mammogram obtained at the onset of the procedure was found to be helpful in localization, but otherwise the number of images was the same regardless of imaging receptor. Mean glandular dose was reduced by about 50% with digital imaging from 0.219 to 0.120 cGy. In those 17% (33/190) of needle localizations that could not be completed with digital imaging, failure was due to a variety of factors. Despite improved detectability of fibrils, specks, and masses on digital images, digital systems did not show some fine calcifications or soft-tissue masses during needle localizations. Difficulty in imaging lesions near the chest wall or in the axilla and the small field of view also caused procedures attempted with digital imaging to be aborted and completed with film-screen systems. CONCLUSION: The time to complete needle localization was reduced by 50%, with a similar reduction in patients' radiation dose, when digital mammography was used. These findings should be applicable to stereotaxic procedures done with digital mammography. Factors limiting the use of digital mammography equipment included inability to image some fine calcifications and some masses, difficulty in imaging near the chest wall and in the axilla, and a small field of view.

Breast Neoplasms↗

Update on interventional treatment of urinary obstruction.

During the last 20 years percutaneous nephrostomy has evolved as one of the basic procedures in the management of obstructive uropathy. This procedure is now widely available, it is relatively safe, and it offers rapid treatment of urinary obstruction regardless of underlying cause. Percutaneous nephrostomy is also the first step in a variety of antegrade ureteral procedures, including stent placement and ureteral dilation.

Humans↗

Wallstent migration following deployment in right and left bile ducts.

The Wallstent biliary endoprosthesis has recently been approved for treatment of malignant bile duct obstruction. Although minor changes in position have occurred, migration of these stents has been uncommon. The authors report a case in which migration occurred when stents were simultaneously deployed in the right and left bile ducts. Several mechanisms for this complication are postulated.

Bile Ducts↗

Hypoplastic pulmonary artery: an unusual entity mimicking pulmonary embolism during pregnancy.

Hypoplastic pulmonary artery is an unusual congenital malformation. We describe a case of hypoplastic pulmonary artery diagnosed during the third trimester of pregnancy. The clinical and radiologic features mimicked pulmonary embolism, including hemoptysis, chest pain, pleural effusion, mild hypoxemia, and a suggestive ventilation-perfusion scan. Accurate differentiation of this entity from pulmonary embolism is necessary to obviate the need for prolonged anticoagulation.

Adult↗