PubMed Health⌕ Search

Biomedical subjects

A F Frangi

Publications and source records attributed to A F Frangi.

6 recordsLinked to original sources

Outlook for grid service technologies within the @neurIST eHealth environment.

The aim of the @neurIST project is to create an IT infrastructure for the management of all processes linked to research, diagnosis and treatment development for complex and multi-factorial diseases. The IT infrastructure will be developed for one such disease, cerebral aneurysm and subarachnoid haemorrhage, but its core technologies will be transferable to meet the needs of other medical areas. Since the IT infrastructure for @neurIST will need to encompass data repositories, computational analysis services and information systems handling multi-scale, multi-modal information at distributed sites, the natural basis for the IT infrastructure is a Grid Service middleware. The project will adopt a service-oriented architecture because it aims to provide a system addressing the needs of medical researchers, clinicians and health care specialists (and their IT providers/systems) and medical supplier/consulting industries.

Database Management Systems↗

Myocardial motion estimation in tagged MR sequences by using alphaMI-based non rigid registration.

Tagged Magnetic Resonance Imaging (MRI) is currently the reference MR modality for myocardial motion and strain analysis. NMI-based non rigid registration has proven to be an accurate method to retrieve cardiac deformation fields. The use of alphaMI permits higher dimensional features to be implemented in myocardial deformation estimation through image registration. This paper demonstrates that this is feasible with a set of Haar wavelet features of high dimension. While we do not demonstrate performance improvement for this set of features, there is no significant degradation as compared to implementing the registration method with the traditional NMI metric. We use Entropic Spanning Graphs (ESGs) to estimate the alphaMI of the wavelet feature vectors WFVs since this is not possible with histograms. To the best of our knowledge, this is the first time that ESGs are used for non rigid registration.

Algorithms↗

Parametric optimization of a model-based segmentation algorithm for cardiac MR image analysis: a grid-computing approach.

In this work we present a Grid-based optimization approach performed on a set of parameters that affects both the geometric and grey-level appearance properties of a three-dimensional model-based algorithm for cardiac MRI segmentation. The search for optimal values was assessed by a Monte Carlo procedure using computational Grid technology. A series of segmentation runs were conducted on an evaluation database comprising 30 studies at two phases of the cardiac cycle (60 datasets), using three shape models constructed by different methods. For each of these model-patient combinations, six parameters were optimized in two steps: those which affect the grey-level properties of the algorithm first and those relating to the geometrical properties, secondly. Two post-processing tasks (one for each stage) collected and processed (in total) more than 70000 retrieved result files. Qualitative and quantitative validation of the fitting results indicates that the segmentation performance was greatly improved with the tuning. Based on the experienced benefits with the use of our middleware, and foreseeing the advent of large-scale tests and applications in cardiovascular imaging, we strongly believe that the use of Grid computing technology in medical image analysis constitutes a real necessity.

Algorithms↗

Quantitative analysis of vascular morphology from 3D MR angiograms: In vitro and in vivo results.

A 3D model-based approach for quantification of vascular morphology from several MRA acquisition protocols was evaluated. Accuracy, reproducibility, and influence of the image acquisition techniques were studied via in vitro experiments with ground truth diameters and the measurements of two expert readers as reference. The performance of the method was similar to or more accurate than the manual assessments and reproducibility was also improved. The methodology was applied to stenosis grading of carotid arteries from CE MRA data. In 11 patients, the approach was compared to manual scores (NASCET criterion) on CE MRA and DSA images, with the result that the model-based technique correlates better with DSA than the manual scores. Spearman's correlation coefficient was 0.91 (P < 0.001) for the model-based technique and DSA vs. 0.80 and 0.84 (P < 0.001) between the manual scores and DSA. From the results it can be concluded that the approach is a promising objective technique to assess geometrical vascular parameters, including degree of stenosis. Magn Reson Med 45:311-322, 2001.

Algorithms↗

Three-dimensional modeling for functional analysis of cardiac images: a review.

Three-dimensional (3-D) imaging of the heart is a rapidly developing area of research in medical imaging. Advances in hardware and methods for fast spatio-temporal cardiac imaging are extending the frontiers of clinical diagnosis and research on cardiovascular diseases. In the last few years, many approaches have been proposed to analyze images and extract parameters of cardiac shape and function from a variety of cardiac imaging modalities. In particular, techniques based on spatio-temporal geometric models have received considerable attention. This paper surveys the literature of two decades of research on cardiac modeling. The contribution of the paper is three-fold: 1) to serve as a tutorial of the field for both clinicians and technologists, 2) to provide an extensive account of modeling techniques in a comprehensive and systematic manner, and 3) to critically review these approaches in terms of their performance and degree of clinical evaluation with respect to the final goal of cardiac functional analysis. From this review it is concluded that whereas 3-D model-based approaches have the capability to improve the diagnostic value of cardiac images, issues as robustness, 3-D interaction, computational complexity and clinical validation still require significant attention.

Diagnostic Imaging↗

Model-based quantitation of 3-D magnetic resonance angiographic images.

Quantification of the degree of stenosis or vessel dimensions are important for diagnosis of vascular diseases and planning vascular interventions. Although diagnosis from three-dimensional (3-D) magnetic resonance angiograms (MRA's) is mainly performed on two-dimensional (2-D) maximum intensity projections, automated quantification of vascular segments directly from the 3-D dataset is desirable to provide accurate and objective measurements of the 3-D anatomy. A model-based method for quantitative 3-D MRA is proposed. Linear vessel segments are modeled with a central vessel axis curve coupled to a vessel wall surface. A novel image feature to guide the deformation of the central vessel axis is introduced. Subsequently, concepts of deformable models are combined with knowledge of the physics of the acquisition technique to accurately segment the vessel wall and compute the vessel diameter and other geometrical properties. The method is illustrated and validated on a carotid bifurcation phantom, with ground truth and medical experts as comparisons. Also, results on 3-D time-of-flight (TOF) MRA images of the carotids are shown. The approach is a promising technique to assess several geometrical vascular parameters directly on the source 3-D images, providing an objective mechanism for stenosis grading.

Algorithms↗