PubMed Health⌕ Search

Biomedical subjects

A F Laine

Publications and source records attributed to A F Laine.

7 recordsLinked to original sources

Improving PET-based physiological quantification through methods of wavelet denoising.

The goal of this study was to evaluate methods of multidimensional wavelet denoising on restoring the fidelity of biological signals hidden within dynamic positron emission tomography (PET) images. A reduction of noise within pixels, between adjacent regions, and time-serial frames was achieved via redundant multiscale representations. In analyzing dynamic PET data of healthy volunteers, a multiscale method improved the estimate-to-error ratio of flows fivefold without loss of detail. This technique also maintained accuracy of flow estimates in comparison with the "gold standard," using dynamic PET with O15-water. In addition, in studies of coronary disease patients, flow patterns were preserved and infarcted regions were well differentiated from normal regions. The results show that a wavelet-based noise-suppression method produced reliable approximations of salient underlying signals and led to an accurate quantification of myocardial perfusion. The described protocol can be generalized to other temporal biomedical imaging modalities including functional magnetic resonance imaging and ultrasound.

Adult↗

LV volume quantification via spatiotemporal analysis of real-time 3-D echocardiography.

This paper presents a method of four-dimensional (4-D) (3-D + Time) space-frequency analysis for directional denoising and enhancement of real-time three-dimensional (RT3D) ultrasound and quantitative measures in diagnostic cardiac ultrasound. Expansion of echocardiographic volumes is performed with complex exponential wavelet-like basis functions called brushlets. These functions offer good localization in time and frequency and decompose a signal into distinct patterns of oriented harmonics, which are invariant to intensity and contrast range. Deformable-model segmentation is carried out on denoised data after thresholding of transform coefficients. This process attenuates speckle noise while preserving cardiac structure location. The superiority of 4-D over 3-D analysis for decorrelating additive white noise and multiplicative speckle noise on a 4-D phantom volume expanding in time is demonstrated. Quantitative validation, computed for contours and volumes, is performed on in vitro balloon phantoms. Clinical applications of this spaciotemporal analysis tool are reported for six patient cases providing measures of left ventricular volumes and ejection fraction.

Cardiac Volume↗

Use of wavelet transforms in analysis of time-activity data from cardiac PET.

UNLABELLED: Because of its intrinsic quantitative properties, PET permits measurement of myocardial perfusion and metabolism in absolute terms (i.e., mL/g/min). However, quantification has been limited by errors produced in image acquisition, selection of regions of interest, and data analysis. The goal of this study was to evaluate a newly developed, novel, wavelet-based noise-reduction approach that can objectively extract biologic signals hidden within dynamic PET data. METHODS: Quantification of myocardial perfusion using dynamic PET imaging with 82Rb, H2(15)O, and 13NH3 was selected to evaluate the effects of the wavelet-based noise-reduction protocol. Dynamic PET data were fitted to appropriate mathematic models before and after wavelet-based noise reduction to get flow estimates. Time-activity curves, precision, accuracy, and differentiating capacity derived from the wavelet protocol were compared with those obtained from unmodified data processing. A total of 84 human studies was analyzed, including 43 at rest (18 82Rb scans, 18 H2(15)O scans, and 7 13NH3 scans) and 41 after coronary hyperemia with dipyridamole (17 82Rb scans, 17 H2(15)O scans, and 7 13NH3 scans). RESULTS: For every tracer tested under all conditions, the wavelet method improved the shape of blood and tissue time-activity curves, increased estimate-to-error ratios, and maintained fidelity of flow in regions as small as 0.85 cm3. It also improved the accuracy of flow estimates derived from 82Rb to the level of that achieved with H2(15)O, which was not affected markedly by the wavelet process. In studies of patients with coronary disease, regional heterogeneity of myocardial perfusion was preserved and flow estimates in infarcted regions were differentiated more easily from normal regions. CONCLUSION: The wavelet-based noise-reduction method effectively and objectively extracted tracer time-activity curves from data with low signal-to-noise ratios and improved the accuracy and precision of measurements with all tracer techniques studied. The approach should be generalizable to other image modalities such as functional MRI and CT and, therefore, improve the ability to quantify dynamic physiologic processes.

Coronary Circulation↗

Quantification of myocardial perfusion in human subjects using 82Rb and wavelet-based noise reduction.

UNLABELLED: Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of flow estimates after the application of a novel multidimensional wavelet-based noise-reduction protocol. METHODS: Myocardial perfusion was estimated using 82Rb and a two-compartment model from dynamic PET scans on 11 healthy volunteers at rest and after hyperemic stress with dipyridamole. Midventricular planes were divided into eight regions of interest, and a wavelet transform protocol was applied to images and time-activity curves. Flow estimates without and with the wavelet approach were compared with those obtained using H2(15)O. RESULTS: Over a wide flow range (0.45-2.75 mL/g/min), flow achieved with the wavelet approach correlated extremely closely with values obtained with H2(15)O (y = 1.03 x -0.12; n = 23 studies, r = 0.94, P < 0.001). If the wavelet noise-reduction technique was not used, the correlation was less strong (y = 1.11 x + 0.24; n = 23 studies, r = 0.79, P < 0.001). In addition, the wavelet approach reduced the regional variation from 75% to 12% and from 62% to 11% (P < 0.001 for each comparison) for resting and stress studies, respectively. CONCLUSION: The use of a wavelet protocol allows near-optimal noise reduction, markedly enhances the physiologic flow signal within the PET images, and enables accurate measurement of myocardial perfusion with 82Rb in human subjects over a wide range of flows.

Adult↗

Wavelets in temporal and spatial processing of biomedical images.

We review some of the most recent advances in the area of wavelet applications in medical imaging. We first review key concepts in the processing of medical images with wavelet transforms and multiscale analysis, including time-frequency tiling, overcomplete representations, higher dimensional bases, symmetry, boundary effects, translational invariance, orientation selectivity, and best-basis selection. We next describe some applications in magnetic resonance imaging, including activation detection and denoising of functional magnetic resonance imaging and encoding schemes. We then present an overview in the area of ultrasound, including computational anatomy with three-dimensional cardiac ultrasound. Next, wavelets in tomography are reviewed, including their relationship to the radon transform and applications in position emission tomography imaging. Finally, wavelet applications in digital mammography are reviewed, including computer-assisted diagnostic systems that support the detection and classification of small masses and methods of contrast enhancement.

Algorithms↗

Speckle reduction and contrast enhancement of echocardiograms via multiscale nonlinear processing.

This paper presents an algorithm for speckle reduction and contrast enhancement of echocardiographic images. Within a framework of multiscale wavelet analysis, we apply wavelet shrinkage techniques to eliminate noise while preserving the sharpness of salient features. In addition, nonlinear processing of feature energy is carried out to enhance contrast within local structures and along object boundaries. We show that the algorithm is capable of not only reducing speckle, but also enhancing features of diagnostic importance, such as myocardial walls in two-dimensional echocardiograms obtained from the parasternal short-axis view. Shrinkage of wavelet coefficients via soft thresholding within finer levels of scale is carried out on coefficients of logarithmically transformed echocardiograms. Enhancement of echocardiographic features is accomplished via nonlinear stretching followed by hard thresholding of wavelet coefficients within selected (midrange) spatial-frequency levels of analysis. We formulate the denoising and enhancement problem, introduce a class of dyadic wavelets, and describe our implementation of a dyadic wavelet transform. Our approach for speckle reduction and contrast enhancement was shown to be less affected by pseudo-Gibbs phenomena. We show experimentally that this technique produced superior results both qualitatively and quantitatively when compared to results obtained from existing denoising methods alone. A study using a database of clinical echocardiographic images suggests that such denoising and enhancement may improve the overall consistency of expert observers to manually defined borders.

Algorithms↗

A wavelet-based metric for visual texture discrimination with applications in evolutionary ecology.

Much work on natural and sexual selection is concerned with the conspicuousness of visual patterns (textures) on animal and plant surfaces. Previous attempts by evolutionary biologists to quantify apparency of such textures have involved subjective estimates of conspicuousness or statistical analyses based on transect samples. We present a method based on wavelet analysis that avoids subjectivity and that uses more of the information in image textures than transects do. Like the human visual system for texture discrimination, and probably like that of other vertebrates, this method is based on localized analysis of orientation and frequency components of the patterns composing visual textures. As examples of the metric's utility, we present analyses of crypsis for tigers, zebras, and peppered moth morphs.

Animals↗