PubMed HealthSearch

Biomedical subjects

A F Maizza

Publications and source records attributed to A F Maizza.

2 recordsLinked to original sources

Heart valve bioprosthesis durability: a challenge to the new generation of porcine valves.

Long-term experience with first generation porcine valve xenografts enabled identification of the major limitations to their durability: (1) prosthetic-ventricular mismatch due to the high profile of the stent in patients with mitral stenosis and a small left ventricle; (2) high-pressure fixation with loss of natural collagen crimping in the fibrosa, and wash-out of proteoglycans in the spongiosa; (3) xenograft tissue autolysis, due to the long interval between animal slaughter and aortic valve removal fixation; (4) muscle shelf in the right coronary cusp, which created a gradient and could undergo accelerated calcification and/or spontaneous perforation with time; (5) a flexible polypropylene stent, which could creep or even fracture with consequent inward bending of the stent; (6) progressive time-related dystrophic calcification; (7) host fibrous tissue ingrowth. An awareness of these limitations stimulated technical modifications, which frequently brought about distinct improvements: (1) the reduction of the stent profile eliminated the problem of mismatch, but resulted in a higher tendency towards cusp prolapse and earlier commissural tearing; (2) natural collagen waviness, proteoglycans and cusp extensibility were preserved by employing low or even zero pressure during the fixation process; (3) earlier valve fixation enabled preservation of cell integrity; (4) a new orifice for small valves was designed by replacing the right muscular cusp, thus achieving less gradient and avoiding muscle-shelf-related complications; (5) polypropylene was replaced by Delrin as stent material; (6) calcium-retarding agents like T6 and toluidine blue were applied during commercial processing and storage in order to mitigate tissue mineralization.(ABSTRACT TRUNCATED AT 250 WORDS)

Bioprosthesis

[Structural changes in valve prostheses].

All available prostheses, either mechanical or biological, may undergo structural alterations which are cause of reoperation or death. Some of these complications are common to all valves, whereas some are specific for certain models. Modern mechanical prostheses usually are resistant to structural deterioration, but still thrombogenic thus requiring long-term anticoagulation therapy to avoid thrombotic and thromboembolic episodes, which implies the risk of anticoagulation related hemorrhages. Bioprostheses, on the other hand, present a lower thrombogenicity, however they undergo by definition structural degeneration, especially dystrophic calcification, which is usually cause of reoperation within 8-10 years from implantation. Other prosthetic complications, such as infective endocarditis and fibrous tissue overgrowth, are common to both types of prostheses.

Bioprosthesis