Catheter ablation without fulguration: design and performance of a new system.

A new system is described for catheter ablation which comprises a short time capacitive power source and a specially designed catheter. The aim of the new system is to deliver high voltages with minimal or no arcing and thus avoid the risks associated with barotrauma. The performance of the new system was compared in a saline tank with that of the conventional system. The new system allowed significant increases in delivered voltage, current and energy without arcing. This new system should allow safer catheter ablation.

Electric Countershock↗

The automatic implantable cardioverter/defibrillator for a life threatening arrhythmia in a case of post-partum cardiomyopathy.

We report the development of severe life threatening polymorphic ventricular tachycardia in a young woman shortly following her first pregnancy, who ultimately required the insertion of an automatic implantable cardioverter/defibrillator because of the failure of conventional antiarrhythmic therapy. Although only about 7 patients have received units in the UK to date, the experience in the USA, where up to 300 per month may be implanted, suggests that they will become a more common method of treatment in cases of life threatening arrhythmias.

Adult↗

Additional improvement of stenosis geometry in human coronary arteries by stenting after balloon dilatation.

The purpose of this study was to assess the early changes in stenosis geometry after insertion of intravascular stents in human coronary arteries. Morphologic changes were evaluated by quantitative coronary angiography (using automated edge detection) and by calculation of the theoretical pressure decrease across the dilated and stented stenosis from the Poiseuille and turbulent resistances assuming a coronary blood flow of either 1 or 3 ml/s. Twenty-six patients were studied before and after angioplasty, as well as immediately after stent implantation. The stented coronary artery was the left anterior descending artery in 19 cases, the circumflex artery in 2 cases, the right coronary artery in 2 cases and a coronary artery bypass vein graft in 3 cases. After stent implantation, an additional increase in minimal luminal cross-sectional area of the dilated vessel was observed, suggesting that the self-expanding stainless steel endoprosthesis used in this study has a dilating function in addition to its stenting role.

Angiography↗

Early and late assessment of stenosis geometry after coronary arterial stenting.

Early and late modifications of stenosis geometry after stenting of coronary arteries were assessed. Morphologic changes were evaluated by quantitative coronary angiography (automated edge-detection) and theoretical pressure drop across the dilated and stented stenosis was calculated from the Poiseuille formula, with turbulent resistances assuming a coronary blood flow of 1 or 3 ml/s. Eleven patients (ages 41 to 69 years, mean 55) were studied before and after angioplasty, and immediately after stent implantation. The stented coronary artery was the left anterior descending artery in 9 patients and the left circumflex in 2. Following stent implantation, an additional increase in minimal luminal cross-sectional area of the dilated vessel was observed, suggesting that the self-expanding stainless-steel endoprosthesis used had a dilating function in addition to its stenting role. Repeat angiography in 6 patients 3 months after stent implantation showed a decrease in the minimal luminal cross-sectional area without a significant change in theoretic pressure decrease. This slight reduction in vessel caliber had no hemodynamically significant repercussions. Thus, stenting of coronary arteries following dilatation is a potentially valuable technique for preventing both abrupt closure and late reduction in lumen diameter.

Adult↗

Effects of intracoronary isosorbide dinitrate during acute myocardial ischaemia: a study during angioplasty.

The effects of isosorbide dinitrate on acute myocardial ischaemia were studied in 19 patients during coronary angioplasty. The duration of balloon inflation to the onset of ST segment depression was increased by the administration of intracoronary isosorbide dinitrate from (mean +/- SEM) 13 +/- 2 to 20 +/- 2 s (48%) (P less than 0.01) and the duration to 1 mm ST segment depression increased form 23 +/- 2 to 29 +/- 3 s (28%) (P less than 0.01). Systolic blood pressure fell from 118 +/- 3 to 111 +/- 4 mmHg but there was no change in intracoronary distal occlusion pressure. Thus during coronary occlusion isosorbide dinitrate prolongs the time to the onset of myocardial ischaemia.

Acute Disease↗

Perforation thresholds and safety factors in in vivo coronary laser angioplasty.

Laser angioplasty can cause early (acute perforation) or late (stenosis or aneurysm) complications. To find how much intravascular laser energy can be delivered via a 100 microns core optical fibre passed down a balloon angioplasty catheter without causing angiographic abnormalities up to 10 days later, argon laser energy was delivered percutaneously under radiographic screening to the coronary circulation of 12 normal closed chest dogs. With the balloon inflated, sequential laser pulses were delivered to the same site. Angiograms were recorded before, immediately, and again at one week, after laser delivery. There were two laser-induced perforations (both fatal). Mechanical perforation with the 100 microns fibre occurred four times, but there were no haemodynamic sequelae. To find the acute perforation threshold of similar sized arteries to energy delivered via the bare 100 microns core fibre, the tip of which was held in contact with the luminal surface, 32 argon laser pulses were delivered transluminally in vivo to separate sites in normal rabbit iliac and canine coronary arteries. The acute perforation threshold with energy delivered via the angioplasty catheter lay between 6 and 10 J and that without the balloon angioplasty catheter lay between 3 and 4 J. After delivery of up to 6 J via a balloon angioplasty catheter, there were no angiographic abnormalities at one week. Fibre optic transluminal delivery of laser energy may improve the primary success rate of, and perhaps widen the indications for, coronary angioplasty.

Angioplasty, Balloon↗

Myocardial potassium loss after acute coronary occlusion in humans.

Animal studies have established that there is a rapid increase in extracellular potassium concentration in myocardial tissue after the onset of ischemia. To study this phenomenon in humans, coronary sinus plasma potassium concentration was measured in five patients undergoing therapeutic coronary angioplasty. Recordings were obtained during a total of 22 coronary artery occlusions lasting between 5 and 50 seconds. Though little change was observed during angioplasty balloon inflation, all occlusions that lasted more than 15 seconds were followed by a transient elevation in coronary sinus potassium concentration of between 0.18 and 1.55 mmol X liter-1. The majority of occlusions (n = 17) were not accompanied by chest pain, electrocardiographic (ECG) changes or alteration of heart rate. The increase in coronary sinus potassium concentration after angioplasty balloon deflation is attributable to a washout of accumulated extracellular potassium during reperfusion. Redistribution of human myocardial potassium occurs within 15 seconds of the onset of myocardial ischemia and may be an important factor accounting for early electrophysiologic changes.

Acute Disease↗

The NASPE/BPEG generic pacemaker code for antibradyarrhythmia and adaptive-rate pacing and antitachyarrhythmia devices.

A new generic pacemaker code, derived from and compatible with the Revised ICHD Code, was proposed jointly by the North American Society of Pacing and Electrophysiology (NASPE) Mode Code Committee and the British Pacing and Electrophysiology Group (BPEG), and has been adopted by the NASPE Board of Trustees. It is abbreviated as the NBG (for "NASPE/BPEG Generic") Code, and was developed to permit extension of the generic-code concept to pacemakers whose escape rate is continuously controlled by monitoring some physiologic variable, rather than determined by fixed escape intervals measured from stimuli or sensed depolarizations, and to antitachyarrhythmia devices including cardioverters and defibrillators. The NASPE/BPEG Code incorporates an "R" in the fourth position to signify rate modulation (adaptive-rate pacing), and one of four letters in the fifth position to indicate the presence of antitachyarrhythmia-pacing capability or of cardioversion or defibrillation functions.

Bradycardia↗

Coronary sinus pH during percutaneous transluminal coronary angioplasty: early development of acidosis during myocardial ischaemia in man.

Coronary sinus pH was measured continuously in eight patients undergoing angioplasty to the left anterior descending coronary artery. A catheter tip pH sensitive electrode with a response time of less than 300 ms and an output of greater than or equal to 57 mV/pH unit was placed high in the coronary sinus. Recordings were obtained during a total of 24 balloon occlusions of the left anterior descending coronary artery varying in duration from 5 to 45 s. Continuous 12 lead surface electrocardiograms were recorded. During or after balloon inflation of greater than or equal to 12 s (n = 4) there was no change in coronary sinus pH or the electrocardiogram. During balloon inflation of greater than or equal to 15 s (n = 20) coronary sinus pH was unaltered but between 4 and 6 s after balloon deflation coronary sinus pH fell transiently by between 0.010 and 0.120 pH units before returning to the control value within 65 s. Ischaemic changes were seen on the electrocardiogram during 15 balloon occlusions. In individual patients the peak fall in coronary sinus pH was related to the duration of occlusion of the left anterior descending coronary artery. A rise in coronary sinus pH (alkalosis) was never seen. In man acidosis occurs in the myocardium after short periods (greater than or equal to 12 s) of ischaemia. The fall of pH precedes ischaemic changes on the surface electrocardiogram and occurs concurrently with the earliest reported changes in contractile function.

Acidosis↗

Importance of "reciprocal" electrocardiographic changes during occlusion of left anterior descending coronary artery. Studies during percutaneous transluminal coronary angioplasty.

ST-segment depression remote from the region of acute myocardial infarction was investigated in three groups of patients undergoing left anterior descending coronary angioplasty. Ten patients had single-vessel disease, nine concomitant stenoses in one or more other major coronary arteries, and two myocardial infarction after occlusion during angioplasty. Continuous surface electrocardiograms were recorded from leads I, II, III, v2, and v5, before, during, and after coronary angioplasty and ST-segment changes were measured to 0.1 mm. All ten patients with single-vessel disease had ST-segment elevation in lead v2 and nine also had changes in lead III. All nine patients with multivessel disease had ST-segment changes in lead v2; eight of them had concomitant changes in lead III. Both patients with myocardial infarction had elevation in lead v2 and depression in lead III. ST-segment changes began simultaneously in all leads where they occurred. Most (70%) patients with single-vessel disease who had inferior ST-segment depression had a right-dominant coronary circulation. Therefore, the presence of inferior ST-segment depression during left anterior descending coronary artery occlusion does not indicate the presence or absence of multivessel disease. Furthermore, it is unlikely that this change always represents ischaemia remote from the site of infarction; it is merely an electrical phenomenon.

Aged↗

Optical transmission of normal and atheromatous arterial wall: a spectral analysis.

In laser angioplasty one of the factors influencing the immediate damage (and therefore the risk of acute arterial perforation) is the optical absorption characteristics of the target tissue. In an attempt to evaluate the differences in optical absorptive properties, the transmission spectrograms of samples of normal and atheromatous human postmortem aortic wall were measured over the visible spectrum. Optical transmission varied inversely with sample thickness and directly with wavelength through both normal and atheromatous samples. Over the whole visible spectrum atheromatous tissue transmitted less per unit thickness than normal tissue. This differential effect was, however, most pronounced at 500 nm, where atheromatous tissue transmitted light 5-10 times less strongly than normal aortic wall. Such wavelength dependent differential optical absorption could provide a means for the selective photovaporisation of atheroma in laser angioplasty.

Angioplasty, Balloon↗

A new low energy power source for catheter ablation.

The current technology in the area of catheter ablation for cardiac arrhythmia is limited by the amount of damage sustained by the ablated area in relationship to the energy used. Thus, a newly designed power source is described in this report in three patients, two with resistant atrial flutter/fibrillation and one with a reentrant AV tachycardia. The delivered energy in all patients was 5.1 joules or less with the exception of a single shock of 37.5 joules, which was required in one patient. We conclude that this effort of low energy ablation using a unique power source represents an advance in the field of ablation that merits further evaluation.

Aged↗

Incidence of spasm at the site of previous successful transluminal coronary angioplasty: effect of ergometrine maleate in consecutive patients.

The incidence of coronary artery spasm at the site of previous successful angioplasty and its importance in leading to subsequent restenosis or recurrence of symptoms are unknown. Fourteen consecutive patients with single vessel coronary artery disease who had undergone successful percutaneous transluminal angioplasty were studied. All patients were given ergometrine maleate (ergonovine maleate) intravenously during repeat cardiac catheterisation six weeks to three months after angioplasty. Five patients demonstrated excessive luminal reduction (spasm) at the site of previous angioplasty that led to luminal stenoses ranging from 50% to 79%. Two of these patients developed chest pain and ST segment changes during ergometrine maleate provocation and they also showed maximal vasoconstriction. The remaining nine patients did not develop important luminal change at the site of angioplasty after ergometrine maleate. Ergometrine maleate administration resulted in less than or equal to 20% reduction in lumen diameter of adjacent apparently normal sections of the coronary arteries in all but two patients. At the site of previous angioplasty in the five patients with spasm, however, the lumen was constricted by a mean (SD) of 51 (12)%, whereas in the nine patients not demonstrating spasm mean reduction was 12 (7)%. Thus hypersensitivity to ergometrine maleate at the site of previous successful angioplasty was demonstrated in over a third of consecutive patients with single vessel coronary artery disease. The importance of this finding to long term results of coronary angioplasty needs to be investigated further.

Angioplasty, Balloon↗

Value of the bipolar lead CM5 in electrocardiography.

Only bipolar lead recording are available during ambulatory monitoring. Their sensitivity in detecting ST segment changes in relation to standard electrocardiographic leads is not known. The magnitude and direction of ST segment changes in the bipolar lead CM5 were compared with those in standard electrocardiographic leads in patients during exercise testing and percutaneous transluminal coronary angioplasty. Thirty patients with coronary artery disease were studied during exercise tests in which ST segment depression (greater than 0.5 mm) occurred in one or more standard electrocardiographic leads and 13 patients were studied during angioplasty that resulted in ST segment change in one or more leads (I, II, III, V2, V5, and CM5). Lead CM5 was the most sensitive lead (93%) during exercise testing and also showed the greatest magnitude of ST segment change below the isoelectric line in 93% of the patients. Only two patients, one with ST segment elevation in inferior leads and one with changes restricted to septal leads, had no ST segment depression in lead CM5. When ST segment shift from the baseline electrocardiogram was measured the magnitude of depression was greatest in lead CM5 in only 63% of the patients. During angioplasty of the left anterior descending coronary artery, lead CM5 showed ST segment depression in seven patients, ST segment elevation in two, and a biphasic response in one. Two of the three patients with balloon inflation in right coronary artery developed ST segment elevation in lead CM5. Thus lead CM5 is a reliable lead for detecting subendocardial ischaemia experienced during everyday activities in anginal patients. During total occlusion of coronary arteries (as in variant angina or myocardial infarction) lead CM5 commonly shows ST segment depression and changes due to right coronary artery occlusion may not be detected.

Coronary Disease↗