PubMed Health⌕ Search

Biomedical subjects

A Frigiola

Publications and source records attributed to A Frigiola.

At least 37 records · Page 2Linked to original sources

Aortic outflow obstruction in visceral heterotaxy: a study based on twenty postmortem cases.

Aortic outflow tract obstruction can complicate the clinical course and surgical management of patients with heterotaxy syndromes, but its anatomic basis has not been described in detail. In 20 postmortem cases with asplenia (n = 4) or polysplenia (n = 16), the anatomic causes of aortic outflow tract obstruction were absence of the subaortic conus in association with (1) narrowing of the subaortic outflow tract between the conal septum anteriorly and the common atrioventricular (AV) valve posteriorly in six (30%) patients; (2) aortic valvar atresia in four (25%), three with asplenia and one with polysplenia; (3) redundant AV valve leaflets in four (20%); (4) excessive AV valve fibrous tissue in four (20%); (5) marked hypoplasia of the mitral valve and left ventricle in two (10%); and (6) aneurysm of membranous septum in one (5%). One patient belonged to group (1) and (4). Aortic outflow tract obstruction was much more common with polysplenia (28%) than with asplenia (4%) (p < 0.001).

Abnormalities, Multiple↗

Normothermic perfusion and lung function after cardiopulmonary bypass: effects in pulmonary risk patients.

Fifty patients at risk for postoperative lung dysfunction and undergoing elective coronary revascularization have been randomly assigned to receive normothermic (36 degrees C) perfusion with warm heart protection (NP group) or hypothermic (28 degrees C) perfusion with cold heart protection (HP group). Lung function before and after cardiopulmonary bypass (CPB) was studied through the determination of the intrapulmonary shunt (Qs/Qt), the alveoloarterial oxygen gradient (A-a delta O2), and the artero-alveolar carbon dioxide gradient (a-A delta CO2). The Qs/Qt after CPB was significantly lower in the NP group (27.1 +/- 2.6 vs 35.7 +/- 2.3) as well as the A-a delta O2 (50.2 +/- 1.5 vs 57.6 +/- 2.4), both data returned to comparable between the groups after 3 h in the intensive care unit. The a-A delta CO2 was significantly lower after CPB in the NP group (5.2 +/- 0.74 vs 8.2 +/- 0.8). Hospital stay and mortality were comparable in the two groups; intubation time and rate of early extubation showed a trend in favour of the NP group; the rate of patients suffering hypoxia and/or hypercapnia after extubation was significantly lower in the NP group (12%) versus the HP group (44%). Normothermia seems to exert a protective effect against lung dysfunction after CPB. The absence of a rewarming injury associated with reperfusion, a limitation of the hypothermic-induced vasoconstriction due to local cooling of the lung and a better compliance of the normothermic lung are hypothesized as beneficial effects of the 'all-warm' strategy.

Aged↗

Beneficial effects of Duraflo II heparin-coated circuits on postperfusion lung dysfunction.

BACKGROUND: Heparin coating of the cardiopulmonary bypass circuit reduces the activation of the terminal part of the complement cascade. Conflicting data are reported concerning neutrophil activation and postoperative lung dysfunction. In this study, we compared three different types of oxygenator: a bubble oxygenator, a conventional hollow-fiber oxygenator, and a heparin-coated oxygenator and circuit. METHODS: Sixty patients undergoing myocardial revascularization were randomly assigned to one of three oxygenator groups. All the patients were free from preoperative lung dysfunction. Lung function was studied with repeated measurements of respiratory index, intrapulmonary shunt, alveolar dead space, ventilation/perfusion ratio, and static thoracopulmonary compliance. RESULTS: Immediately after cardiopulmonary bypass, the intrapulmonary shunt and respiratory index values in the bubble oxygenator and hollow-fiber oxygenator groups increased more than those in the heparin-coated oxygenator group. In the intensive care unit, the between-group difference in intrapulmonary shunt disappeared, but the within-group difference in respiratory index (from baseline) remained for the bubble oxygenator group. The other three variables did not significantly differ between groups. Intubation time and stay in the intensive care unit did not differ between groups. CONCLUSIONS: Heparin-coated circuits exert a protective effect on pulmonary function. However, their use did not modify the postoperative clinical course of patients with normal lung function preoperatively.

Aprotinin↗

Risk factors for renal dysfunction after coronary surgery: the role of cardiopulmonary bypass technique.

We studied 316 patients undergoing cardiopulmonary bypass for coronary artery surgery in order to determine perioperative risk factors for postoperative renal dysfunction. A preliminary univariate analysis was performed by chi 2 analysis for categorical data and Mann-Whitney U-test for continuous variables to detect significant correlations between each risk factor and the occurrence of moderate or severe renal dysfunction. Subsequently, a multiple logistic regression was applied to the three risk factors identified as predictive for severe renal dysfunction. Low cardiac output syndrome and need for banked blood transfusions combined with a low haematocrit value during cardiopulmonary bypass increase the probability of severe renal dysfunction in the postoperative course.

Aged↗

[Percutaneous closure of interatrial defect using the buttoned double-disk prosthesis].

BACKGROUND: Surgical repair is the procedure of choice for atrial septal defect correction. Even though surgical mortality is low (< 1%), morbidity is significant (anesthesia, thoracotomy, cardiopulmonary bypass, longer hospitalization and intensive care unit monitoring). Transcatheter methods to occlude atrial septal defects have been in development during the last two decades. We report our experience in Italy with the Sideris buttoned double-disk device. METHODS: From March 1992 to April 1993, 14 patients aged 20 months to 52 years, weight 10 to 82 kg, underwent transcatheter atrial septal defect occlusion with the Sideris buttoned device. The buttoned device is a miniaturized two disk device introduced through small venous sheaths (8-9 F). The diameter of atrial septal defects by echocardiography varied between 9 and 23 mm, while the balloon stretched diameter of the defects varied between 13 and 24 mm. The devices selected were 19 +/- 4 mm larger than the stretched diameter of the defect, but less than the total length of the septum (33-56 mm) by echo. RESULTS: Pulmonary-to-systemic flow ratio varied between 1.5 to 4.0. Mean pulmonary artery pressure varied between 10 and 24 mmHg (mean value 17 +/- 3.5 mm Hg). The relationship between different atrial septal defect measurements (echo, shunt flow, stretched diameter) was statistically analysed: transthoracic echo diameter had a good correlation with the balloon stretched diameter (r = 0.63, p < 0.001). The atrial septal defect was occluded in 12 patients (86% success rate). There was one early "unbuttoning" which was surgically corrected with success. The other patient underwent surgical correction 3 months later because of unsuitability for transcatheter closure. Minimal residual shunt detected by color flow mapping at 1 month follow-up was seen in 4 patients (33%). No complications occurred in any of our patients. CONCLUSIONS: This initial experience with the Sideris buttoned double-disk device demonstrated that transcatheter closure of atrial septal defect is feasible and effective. It can be accomplished through small introducing sheaths. Further clinical trials are justified. This method could become the procedure of choice for the correction of small ASDs.

Adolescent↗

Infundibular septal defect with severe aortic regurgitation: a new surgical approach.

Aortic regurgitation associated with prolapse of an aortic cusp and an infundibular septal defect is caused by the lack of anatomical support for the aortic annulus by the conal septum. This fact is taken into consideration in the new surgical approach that we performed in 5 children 3 to 16 years of age with infundibular ventricular septal defect and severe aortic regurgitation. The ventricular septal defect is closed by a patch anchored to another patch through the prolapsed cusp. This second patch is pulled up with the prolapsed cusp and is then fixed in the aortic wall. In all 5 patients, all clinical signs of aortic insufficiency disappeared, and only minimal aortic regurgitation could be demonstrated by color Doppler mapping.

Adolescent↗

[Aortocoronary bypass in a child with Kawasaki disease: the follow-up results].

The Kawasaki disease (mucocutaneous lymph node syndrome) usually affects children younger than 5 years, and is considered one of the most important causes of myocardial infarction in children. Some disagreement still exists regarding the following: the selection, surgery techniques, and follow-up outcomes of aortocoronary bypass grafting in Kawasaki disease. We describe the case of a three-year-old child with Kawasaki disease and with left and right multiple aneurysms, suffering from an antero-lateral myocardial infarction and inferior reinfarction. After thrombolytic treatment and coronary arteriography, left anterior descending aortocoronary bypass grafting was performed by using the autologous saphenous vein. After two years clinical, angiographic, ergometric and echocardiographic examinations show good surgical results with a global and regional kinesis improvement.

Child, Preschool↗

[Double mitral valve orifice associated with complete atrioventricular canal. Description of 2 cases].

The Authors describe two cases of double mitral valve orifice associated with complete atrioventricular canal. The first patient, 10 month-old male, affected by type A complete atrioventricular canal, underwent surgical repair which was performed in association with division of the tissue bridge between the two orifices. The patient died the day after because of severe mitral insufficiency and pulmonary oedema. The second patient, 3.5 year-old female, affected by type A complete atrioventricular canal with pulmonary banding, underwent a surgical procedure without division of the tissue bridge. In the postoperative period a suture dehiscence occurred which caused severe mitral regurgitation, and another intervention had to be performed; subsequently the patient did well and was discharged in good condition. The Authors discuss the possible role of two dimensional and Doppler echocardiography in the diagnosis of this uncommon condition; they also discuss the related surgical problems and stress the necessity to repair with a proper compromise between residual mitral insufficiency and a mitral stenosis.

Abnormalities, Multiple↗

[Left ventricular fibroma in childhood: 2-dimensional echocardiographic diagnosis and surgical treatment. Description of a case].

We describe the case of a patient 4 months old transferred to our hospital for evaluation of occasionally detected cardiac alterations: ecg showed abnormal Q and negative T waves in D1 - aVL leads and chest x-ray was consistent with enlargement of the left ventricular cavity. After admission, 2D echocardiographic examination disclosed, in the left ventricular cavity, a large mass extending from the papillary muscles to the outflow tract. The mass was of uniform density and easily recognizable as a tumor. Although asymptomatic, the patient underwent operation 10 months later because of the risk of occurrence of severe conduction disturbances or arrhythmias. Histological examination demonstrated that the mass was a fibroma. At post-op echocardiographic and angiographic evaluation the left ventricle appeared abnormally dilated with a large aneurysm of the lateral wall and very poor pump function. Nevertheless the patient did well in the following months until a ventricular fibrillation occurred at home. He was immediately brought to hospital and resuscitation was attempted unsuccessfully. We discuss the role of 2D echocardiography in the diagnosis of cardiac tumors, the indication of the early surgical removal and the possible limitations of the technique we used in this case.

Echocardiography↗

[Bidimensional echocardiographic diagnosis of the pulmonary valve agenesis syndrome in the newborn infant. Description of 2 cases].

We describe the cases of two neonates affected by the syndrome of pulmonary valve agenesis, in whom non-invasive diagnosis was possible by two dimensional echocardiography. The echocardiographic features we describe are the following: enlargement of the right ventricle in association with ventricular septal defect, malalignment type, dilatation of the right ventricular outflow tract, massive dilation of the main and branch pulmonary arteries, annular pulmonary stenosis. At the expected site of the pulmonary valve two ridges were seen, which did not have the typical motion of a fully developed valve. The ventricular septal motion was paradoxical in both cases. The diagnosis was confirmed at cardiac catheterization and the two neonates underwent operation unsuccessfully. The anatomic post-mortem examination confirmed the echocardiographic and angiographic findings. As successful treatment of this syndrome is difficult, we believe that a non-invasive echocardiographic diagnosis is very useful in order to avoid or, at least, delay a high risk cardiac catheterization.

Dilatation, Pathologic↗

[Echocardiographic aspects of persistence of the right valve of the venous sinus].

The aim of this work is to demonstrate the possibility to identify persistent right sinus venous valve and to differentiate it from other right sided heart pathology by two dimensional echocardiography. We report the echocardiographic findings observed in three out of 215 paediatric patients we examined for clinically suspected congenital heart disease in 12 months period. The first patient was a 24 hours old newborn with transient pulmonary hypertension; the second one was a 6 months old child with pulmonary atresia, severe right ventricular hypertrophy, atrial septal defect and patent ductus arteriosus; the third patient, aged 6 months, had atrial septal defect and mild pulmonary stenosis. In all three patients a particular linear structure was seen, as a membrane that crossed the right atrium from the orifice of the inferior vena cava towards the atrial septum. This structure was identified as persistent right sinus venosus valve according to its morphology, its position into the right atrium and its connection to the atrial septum. The incidence of this echocardiographic finding was 1.4% in our series. In the first case contrast echocardiography from the inferior vena cava demonstrated the deviation of blood flow caused by the persistent sinus valve, although no intra-atrial pressure gradient was shown at cardiac catheterization. In the second patient who died during the operative procedure for making a systemic-pulmonary anastomosis, post mortem examination showed a membranous structure connecting the orifice of the inferior vena cava to the atrial septum.(ABSTRACT TRUNCATED AT 250 WORDS)

Echocardiography↗

[Myocardial protection during repair of congenital heart disease in infants (author's transl)].

The authors use the Bretschneider's cardioplegic solution at 4 degrees C as myocardial preservation in 45 open-heart cases in infants. Using moderate hypothermia at 28 degrees C, the mean myocardial temperature is 17.2 degrees C, using profound hypothermia at 18 degrees C, the mean myocardial temperature is 11.7 degrees C. The reinfusion criteria is myocardial temperature equal or up to perfusion temperature, that is about 40 to 50 minutes after the first infusion. The need of heart defibrillation has been 3 cases over 45 (6.5%). In the early post-operative course they notice 2 low cardiac output syndromes (5%) who responded well at catecholamines infusion. The hospital mortality is 2 deaths over 45 cases, unreliable with myocardial protection.

Child, Preschool↗