PubMed Health⌕ Search

Biomedical subjects

A Fujisawa

Publications and source records attributed to A Fujisawa.

At least 19 recordsLinked to original sources

An unusual vitamin E constituent (alpha-tocomonoenol) provides enhanced antioxidant protection in marine organisms adapted to cold-water environments.

A new vitamin E constituent having an unusual methylene unsaturation at the isoprenoid-chain terminus of alpha-tocopherol (alpha-Toc) was isolated from chum salmon eggs and was found to have identical antioxidant activity as does alpha-Toc in methanol or liposomal suspension at 37 degrees C. Here we report that this marine-derived tocopherol (MDT) is broadly distributed with alpha-Toc in the tissue of marine fish, and that the MDT composition of total vitamin E is greater in the flesh of cold-water salmon (12-20%) than in that of tropical fish (< or =2.5%). Vitamin E analysis of cultured masu salmon maintained on a MDT-deplete diet showed substantially less MDT content than native masu salmon, suggesting a trophic origin of MDT. This contention is supported by the finding of MDT in marine plankton from the cold waters of Hokkaido. We found that MDT inhibited peroxidation of cholesterol-containing phosphatidylcholine liposomes to a greater extent than did alpha-Toc at 0 degrees C. Furthermore, the ratios of the rate constants for MDT and alpha-Toc to scavenge peroxyl radicals increased with decreasing rates of radical flux in liposomes and fish oil at 0 degrees C, indicating that the enhanced activity of MDT at low temperature is attributed to its greater rate of diffusion in viscous lipids. These results suggest that MDT production, or its trophic accumulation, may reduce lipid peroxidation in marine organisms functionally adapted to cold-water environments.

Adaptation, Physiological↗

Observation of toroidal flow antiparallel to the drift direction in the hot electron mode plasmas in the compact helical system.

A toroidal flow antiparallel to the drift direction is observed in the hot electron mode plasmas when a large positive electric field and a sharp electron temperature gradient are sustained inside the internal transport barrier in the Compact Helical System. This toroidal flow reaches up to 5x10(4) m/s at the plasma center, and it is large enough to reverse the toroidal flow driven by a tangentially injected neutral beam. These observations clearly show the plasma favors flow in the minimum nablaB direction at the transport barrier.

Journal Article↗

In vitro evaluation of the heparin-coated Gyro C1E3 blood pump.

The blood-contacting surface, mainly composed of polycarbonate, of the Gyro C1E3 pump was modified using plasma glow discharge to introduce a carboxyl functional group, coated with a base layer of polyethyleneimine as a linker, and coupled with heparin by multi-ionic binding to enhance blood compatibility. A relative surface content of 3.7% sulfur, which demonstrated heparin immobilization on the polycarbonate substrate, was observed on x-ray photoelectron spectroscopy, and a initial bioactivity of approximately 88.5 +/- 7.3 mIU/cm2 was obtained by the chromogenic method for antifactor Xa assay. Furthermore, in vitro observation of platelet and fibrin adherence using bovine blood under dynamic flow conditions for 6 h revealed that the multi-ionically heparinized Gyro C1E3 had significantly stronger antithrombogenecity than the noncoated original type which was evaluated as a good hemocompatible blood pump for clinical use. Not only the Gyro C1E3 but also the ionically heparin-coated Gyro pump are expected to be thromboresistant in clinical use.

Blood Coagulation↗

[A case of squamous cell carcinoma of the oral floor showing a complete response to oral administration of UFT].

A 73-year-old male with squamous cell carcinoma of the oral floor (T1N0M0), who had not consented to radical treatment was treated with UFT by oral administration alone. After commencement of the administration, tumor remission was observed at 2 weeks and disappeared clinically at 8 weeks. The total period of oral administration of UFT was twenty-three months, and the total dose was 186.5 g as tegafur. Major adverse effects were pigmentation of hands and liver dysfunction. He remains under observation, and there is no evidence of tumor recurrence.

Administration, Oral↗

Twenty-three Cases of Primary Cornea Guttata.

Purpose: An evaluation of the clinical aspects of patients with primary cornea guttata and the morphology of their corneal endothelial cells.Methods: Twenty-three patients who visited Kanazawa Medical University Hospital or related hospitals in Ishikawa or Fukui prefectures and were diagnosed as having primary cornea guttata by slit lamp microscopy and contact specular microscopy underwent an analysis of corneal endothelial cells as well as their clinical status.Results: In 23 cases, the number of men and young people under 30 years of age was low, with 4 and 2 cases respectively. There was no visual impairment due to cornea guttata. In the specular microscopic findings, the size and density of dark areas varied according to each case and there was asymmetry in some cases. The parameters of the endothelial cells, comprising mean cell area, hexagonality, and the coefficient of variation, were almost within normal limits except for one eye of a 79-year-old man who was speculated to be at an early stage of Fuch's endothelial corneal dystrophy. Three cases had received cataract surgery, but showed no statistical changes in endothelial morphology before or after the surgery.Conclusion: Cornea guttata is thought to be a disease which is not uncommon in Japanese people and which does not bring about visual impairment or abnormalities in corneal endothelial cell parameters except for a small number of patients. Such cases with remarkably decreased cell densities should be considered to be at an early stage of Fuch's dystrophy.

Journal Article↗

Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study.

The control system for an implantable rotary blood pump is not clearly defined. A detection system is considered to be necessary for pump flow monitoring and abnormal conditions such as back flow or a sucking phenomenon where the septum or left ventricle wall is sucked into the cannula, etc. The ultrasound flowmeter is durable and reliable but the control system should not be totally dependent on the flowmeter. If the flowmeter breaks, the rotary blood pumps have no control mechanism. Therefore, the authors suggest controlling the pumps by an intrinsic parameter. One left ventricular assist device (LVAD) calf model was studied where the flow rate and waveform of the pump flow proved to identify the sucking phenomenon. Thus, the pump flow rate was calculated from the required power, motor speed, and heart rate. The value of the coefficient of determination (R2) between the measured and estimated pump flow rate was 0.796. To estimate this abnormal phenomenon, 2 methods were evaluated. One method was the total pressure head in which the pump flow rate and motor speed were estimated. During normal conditions the total pressure head is 79.5 +/- 7.0 mm Hg whereas in the abnormal condition, it is 180.0 +/- 2.8 mm Hg. There was a statistical difference (p < 0.01). Another method is using a current waveform. There is an association between the current and pump flow waves. The current was differentiated and squared to calculate the power of the differentiated current. The normal range of this value was 0.025 +/- 0.029; the abnormal condition was 11.25 +/- 15.13. There was a statistical difference (p < 0.01). The predicted flow estimation method and a sucking detection method were available from intrinsic parameters of the pump and need no sensors. These 2 methods are simple, yet effective and reliable control methods for a rotary blood pump.

Animals↗

Gyro pump wear and deformation analysis in vivo study: creep deformation.

The Gyro pump has a double pivot bearing system to support its impeller. In this study, the integrity of the bearing system was examined after ex vivo studies. The pumps were implanted into calves and evaluated for different periods as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to a test of 30 days, 1 for 15 days, 4 for 14 days, 1 for 10 days, 1 for 7 days, 2 for 4 days, and 4 for 2 days. One additional pump was subjected to percutaneous cardiopulmonary support (PCPS) condition for 6 days (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an achieved clotting time (ACT) of 200-250 s during the LVAD study and 250-300 s during the PCPS study. After the experiment, the pumps were disassembled, and the wear and deformation of male and female bearings were analyzed. There were no dimensional changes on male bearings but there were on female bearings. Wear and deformation of the female bearings were calculated as follows: wear and deformation = (depth of female before pumping) - (depth after pumping). Thirteen assembled Gyro pumps were disassembled to measure the depth of the female bearings before pumping. There was no statistical relationship between the wear and deformation and the motor speed x driving period. From these results, the deformation was not due to wear but to the creep or elastic deformation. This study suggested that the double pivot bearing system of the Gyro pump is highly durable.

Animals↗

Antithrombogenicity evaluation of a centrifugal blood pump.

The Gyro C1E3 pump was developed not only for cardiopulmonary bypass but also as a short-term assist device. The main purpose of this study was to examine the correlation between the thrombus formation factor and the Gyro C1E3 pumps. Seven pumps were implanted into 3 calves and evaluated for different periods of duration as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to percutaneous cardiopulmonary support condition (PCPS) (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an activated clotting time (ACT) of 200-250 during the LVAD study and 250-300 during the PCPS study. After the experiment, the pumps were disassembled and examined. In cases where there were any blood-derived deposits inside the pumps, the dry weight of these thrombi that adhered to the bearing area of the pump was measured. A multiple correlation was attempted to speculate possible thrombus formation. The estimated dry weight of thrombi was calculated from pump flow rate, pumping day, motor speed, and activated clotting time. This equation was estimated dry weight of thrombi = 1.140 x pump flow rate -0.001 motor speed + 1.652 pumping time -0.041 x ACT + 2.198 R2 = 0.944. This study suggested that there was a possibility to calculate the amount of adhered thrombus formation from pump flow rate, motor speed, pumping day, and ACT.

Animals↗

Particles released from the Gyro C1E3 during simulated extracorporeal circulation.

Evaluation of released particles from the blood pump during extracorporeal circulation is an important aspect because the particles may cause microembolism. The Gyro C1E3 is a centrifugal blood pump that has an impeller suspended by double pivot bearings inside the housing; therefore, it is important to evaluate the released particles. The C1E3 was driven for 14 days to simulate clinical left ventricular assist device (LVAD) and percutaneous cardiopulmonary support (PCPS). Also, a roller pump was driven for 2 days as a comparison. Released particles were weighed and examined by SEM. After 14 days of pumping, the particles from the C1E3 were 238.6 microg in an LVAD condition. The particles with the roller pump were 270.2 microg after only 2 days. Average particle sizes with the roller pump and C1E3 were 3.7 and 0.6 microm, respectively. These results suggest that the Gyro C1E3 substantially reduces the risk of microembolism from released particles.

Biocompatible Materials↗

Impeller design for a miniaturized centrifugal blood pump.

The impeller design for a miniature centrifugal blood pump is an important consideration since the small diameter impeller requires higher rotational speed, which may cause more blood trauma compared to the larger diameter impeller. Three different impeller vanes (straight vanes with a height of 4 mm and 8 mm, and 8 mm curved vanes) of which the diameter was 35 mm were subjected to hydraulic performance and hemolysis tests in the same pump housing. Both straight vane impellers attained left ventricular assist condition (5 L/min against 100 mm Hg) at 2,900 rpm while the curved vane required 3,280 rpm. There was no significant hemolysis difference between the tall and short vanes. The curved impeller vanes did not exhibit sufficient hydraulic performance when compared to the straight vanes. The straight vane impellers, even with different heights, were incorporated into the same pump housings, and the vane heights did not drastically change the hydraulic performance or hemolysis.

Equipment Design↗

Identification and expression of a Mycoplasma gallisepticum surface antigen recognized by a monoclonal antibody capable of inhibiting both growth and metabolism.

In order to identify antigenic proteins of Mycoplasma gallisepticum, monoclonal antibodies (MAbs) against virulent M. gallisepticum R strain were produced in mice. MAb 35A6 was selected for its abilities to inhibit both growth and metabolism of M. gallisepticum in vitro. The MAb recognized a membrane protein with an apparent molecular mass of 120 kDa. The corresponding gene, designated the mgc3 gene, was cloned from an M. gallisepticum genomic DNA expression library and sequenced. The mgc3 gene is a homologue of the ORF6 gene encoding 130-kDa protein in the P1 operon of M. pneumoniae and is localized downstream of the mgc1 gene, a homologue of the P1 gene. To assess the characteristics of MGC3 protein, all 10 TGA codons in the mgc3 gene, which encode a tryptophan in the Mycoplasma species, were replaced with TGG codons, and recombinant fowlpox viruses (FPV) harboring the altered mgc3 gene were constructed. One of the recombinant FPVs was improved to express MGC3 protein on the cell surface in which the signal peptide of MGC3 protein was replaced with one from Marek's disease virus gB. These results should provide the impetus to develop a vaccine based on MGC3 protein which can induce antibodies with both growth inhibition and metabolic-inhibition activities using a recombinant FPV.

Amino Acid Sequence↗

[Twenty-three cases of primary cornea guttata].

PURPOSE: To evaluate the clinical aspects of patients with primary cornea guttata and the morphology of their corneal endothelial cells. METHODS: Twenty-three patients who visited Kanazawa Medical University Hospital or related hospitals in Ishikawa or Fukui prefectures and were diagnosed as having primary cornea guttata by slit lamp microscopy and contact specular microscopy underwent an analysis of corneal endothelial cells as well as their clinical status. RESULTS: In 23 cases, the number of men and young people under 30 years of age was low, with 4 and 2 cases respectively. There was no visual impairment due to cornea guttata. In the specular microscopic findings, the size and density of dark areas varied according to each case and there was asymmetry in some cases. The parameters of the endothelial cells, comprising mean cell area, hexagonality, and the coefficient of variation, were almost within normal limits except for 1 eye of a 79-year-old man who was speculated to be at an early stage of Fuchs' endothelial corneal dystrophy. Three cases had received cataract surgery, but showed no statistical changes in endothelial morphology before or after the surgery. CONCLUSION: Cornea guttata is thought to be a disease which is not uncommon in Japanese people and which does not bring about visual impairment or abnormalities in corneal endothelial cell parameters except for a small number of patients. Such cases with remarkably decreased cell densities should be considered to be at an early stage of Fuchs' dystrophy.

Adult↗

Control system for an implantable rotary blood pump.

Rotary blood pumps can be used for long-term left ventricular assist devices. These pumps have several advantages over the conventional pulsatile pumps including smaller size, higher efficiency, and simple design and construction. However, one of the difficulties associated with the rotary blood pump is the proper control method to maintain an optimum flow rate in different physiological conditions. The rotary blood pump can be controlled by two methods. The first is to utilize the measured pump flow rate from its servo signal. The second is to detect and avoid abnormal pumping conditions such as; back flow and sudden increase in the pressure head. This abnormal situation typically occurs from excessive suction of blood when there is a functional or mechanical occlusion in the inflow cannula. The ultrasound flow meter is durable and reliable but it is difficult to continually monitor the blood flow rate of an implantable pump. Therefore, another method is needed instead of the continuous flow monitoring. One chronic calf having an LVAD was subjected for the development of this control system. This calf survived more than 6 months. Voltage, current, motor speed, heart rate and the pump flow rate were recorded and stored at 30-min intervals in a computer. Utilizing these parameters, attempts were made (1) to achieve indirect flow assessments and (2) to reveal abnormal operating parameters of the centrifugal pump (1). Indirect flow measurement, the predicted pump flow rate was calculated from these pump derived parameters (required power, motor speed and heart rate). The value of the coefficient of determination (R) between the measured and estimated pump flow rate was 0.796. (2) Abnormal operating indicator, there was an association between the required current and pump flow waves. The current was differentiated, and then calculated to the power of the differentiated current. The normal range of this value was 0.02+/-0.54. In abnormal conditions, this abnormal operating indicator increased 500 times. The predicted flow estimation method and abnormal operating indicator were available from intrinsic operating parameters of the pump and need no sensors. These two methods were simple, yet they are possibly effective and reliable servo control methods for a rotary blood pump.

Animals↗

Oxidative stress in newborn infants with and without asphyxia as measured by plasma antioxidants and free fatty acids.

A rapid perfusion of oxygen in infants at birth may cause an increase of oxidative stress. To assess this possibility, we measured levels of blood plasma antioxidants and free fatty acids in 20 normal infants at 0, 1, 3, and 5 days after birth. Plasma levels of the most reactive antioxidant, ascorbic acid, decreased daily to equilibrium values at days 3 and 5. Percentages of oxidized form of coenzyme Q-10 (%CoQ-10) in total coenzyme Q, another good marker of oxidative stress, in infants (25-31%) were significantly higher than those in healthy young adults (4.5%). Plasma levels of total free fatty acids (FFA) in normal infants were highest at day 1 and decreased rapidly thereafter. The content of polyunsaturated fatty acids (PUFA) in total FFA was lowest at day 1 and then increased. Since PUFA are susceptible to oxidation, these changes in FFA composition suggest that oxidative stress is most evident at the initial day of neonatal life. Furthermore, it appears that mono-unsaturated fatty acids such as oleic and palmitoleic acids increase in response to the oxidative loss of PUFA. Similar changes in plasma antioxidants, FFA levels, and FFA compositions were observed in 9 infants with asphyxia. Values of %CoQ-10 in infants with asphyxia were significantly greater than those in normal infants, suggesting that infants with asphyxia have elevated oxidative stress.

Adult↗

Development of a totally implantable biventricular bypass centrifugal blood pump system.

BACKGROUND: During the past 2 years, the development of a totally implantable biventricular bypass rotary blood pump system has been made. METHODS: An extracorporeal gyro centrifugal pump, the CIE3, was miniaturized and developed into the PI601, a totally implantable plastic pump. Two-day anatomic and hemodynamic feasibility studies demonstrated that these two pump systems were easily implantable inside a calf's abdominal wall, directly under the diaphragm. The priming volume of the pump was 20 mL, with sufficient cardiac outputs at approximately 2,000 rpm and requiring less than 10 W of power. Two-week antithrombogenic screening tests also revealed these pump systems to be quite antithrombogenic. In addition, 1-month system reliability studies demonstrated fail-safe reliable performances. RESULTS AND CONCLUSIONS: Encouraged by these preliminary studies, the PI601 model was converted to the permanently implantable titanium gyro pump PI702 model. The long-term implantations were initiated approximately 3 months ago, and two such long-term LVAD studies are currently underway with no sign of difficulty (October 10, 1997). They were followed 283 days and 72 days, respectively. Both terminated due to functional inflow obstruction. There were no blood clots or emboli at autopsy.

Animals↗

A new vitamin E (alpha-tocomonoenol) from eggs of the Pacific salmon Oncorhynchus keta.

A novel alpha-tocomonoenol 3,4-dihydro-2,5,7,8-tetramethyl-2-(4,8,12-trimethyl-12-tridecenyl )-2H-1- benzopyran-6-ol[ having an unusual methylene unsaturation at the isoprenoid-chain terminus of alpha-tocopherol was isolated from the lipophilic fraction of chum salmon eggs. The structure of this marine-derived tocopherol (MDT) was established by spectral analyses. The peroxyl radical-trapping activities of MDT and alpha-tocopherol were compared in aqueous phosphatidylcholine liposomal suspension and in methanolic solution at 37 degrees C. The antioxidant activity of MDT was found to be identical to that of alpha-tocopherol under the experimental conditions of measurement.

Animals↗

Long-term in vivo left ventricular assist device study for 284 days with Gyro PI pump.

A totally implantable centrifugal artificial heart has been developed. The plastic prototype, the Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart (TAH), 2 week screening tests for anti-thrombogenecity, and a 1 month system feasibility study. Based upon these results, a metallic prototype, the Gyro PI 700 series, was subjected to long-term in vivo left ventricular assist device (LVAD) studies of over 1 month. The Gyro PI 700 series has the same inner dimension and same characteristics of the Gyro PI 601 such as an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI metallic pump is also driven with the Vienna DC brushless motor actuator like the PI 601. The pump-actuator package was implanted in 3 calves in the preperitoneal space, bypassing from the left ventricular (LV) apex to the descending aorta. Case 1 achieved a 284 day survival. Case 2 was euthanized early at 72 postoperative days as a result of the functional obstruction of the inlet port due to the excessive growth of the calf. There was no blood clot inside the pumps of either case. Case 3 is on-going (22 days on July 24, 1998). During these periods, all cases showed no physiological abnormalities. In conclusion, the PI 700 series pump has excellent results as a long-term implantable LVAD.

Animals↗