PubMed Health⌕ Search

Biomedical subjects

A Fujishima

Publications and source records attributed to A Fujishima.

At least 19 recordsLinked to original sources

Application of a "black body" like reactor for measurements of quantum yields of photochemical reactions in heterogeneous systems.

We report for the first time an experimental application of the concept of a "black body" like reactor to measure quantum yields (Phi) of photochemical reactions in liquid-solid heterogeneous systems. A major advantage of this new method is its simplicity since the fractions of reflected and transmitted light are negligible due to reactor geometry and high optical density of the heterogeneous systems. The average quantum yield of a test reaction (phenol photodegradation) over TiO(2) (Degussa P25) as determined by this method was 0.14, identical to the quantum yield measured earlier for this same reaction under similar conditions by Salinaro and Serpone. We also report the quantum yield of phenol photodegradation over N-doped TiO(2) during photoexcitation at the fundamental absorption band (lambda = 365 nm; Phi = 0.12) and at the N-doping induced extrinsic absorption band (lambda = 436 nm; Phi = 0.08) of the photocatalyst.

Journal Article↗

Gradient liquid chromatography of leucine-enkephalin peptide and its metabolites with electrochemical detection using highly boron-doped diamond electrode.

Boron-doped diamond thin film (BDD) electrodes have been used to study the oxidation reactions and to detect leucine-enkephalinamide (LEA) and its metabolites, tyrosine (T), tyrosyl-alanine (TA), tyrosyl-alanine-glycine (TAG) and leucine-enkephalin (LE) using cyclic voltammetry (CV), flow-injection analysis (FIA), and gradient liquid chromatography (LC) with amperometric detection. At diamond electrodes, well-defined and highly reproducible cyclic voltammograms were obtained with signal-to-background (S/B) ratios 5-10 times higher than those observed for glassy carbon (GC) electrodes. The analytical peaks of LC for LEA and its metabolites were well resolved. No deactivation of BDD electrodes was found after several experiments with standard as well as plasma samples, indicating high stability of the electrode. Calibration curves were linear over a wide range from 0.06 to 30 microM with regression coefficients of 0.999 for all compounds. The limits of detection obtained based on a signal-to-noise ratio of 3:1 were 3, 2.2, 2.7, 20 and 11 nM for T, TA, TAG, LE and LEA, respectively. These values were at least one order lower than those obtained at GC electrodes, which has given limits of detection of 22.88, 20.64, 89.57, 116.04 and 75.67 for T, TA, TAG, LE and LEA, respectively. Application of this method to real samples was demonstrated and validated using rabbit serum samples. This work shows the promising use of conducting diamond as an amperometric detector in gradient LC, especially for the analysis of enkephalinamide and its metabolites.

Boron↗

Reversible valence tautomerism induced by a single-shot laser pulse in a cobalt-iron Prussian blue analog.

Reversible valence tautomeric conversion induced by a single-shot laser pulse (8 ns duration) with a photon excitation energy of 2.38 eV has been observed in Na0.36Co1.32Fe(CN)(6).5.6H(2)O. A photoswitching process with accompanying magnetization and color changes was successfully achieved within the pulse duration at high temperature (above 200 K) in a thermal hysteresis loop. This unusual photoeffect originates from an optical charge transfer between Fe and Co atoms and evolves due to a cooperative interaction among the local photoexcited sites.

Journal Article↗

Direct electrochemical oxidation of disulfides at anodically pretreated boron-doped diamond electrodes.

Anodically oxidized diamond electrodes have been used to oxidize disulfides, thiols, and methionine in aqueous acidic media and tested for amperometric detection of these compounds after chromatographic separation. Cyclic voltammetric signals for 1 mM glutathione disulfide (GSSG) were observed at 1.39 and 1.84 V vs SCE, the values being less positive than those of its as-deposited counterpart as well as glassy carbon electrode. The voltammetric and chronocoulometric results have indicated the high stability of the electrode with negligible adsorption. A positive shift in the peak potential with increasing pH indicated the attractive electrostatic interaction between the anodically oxidized diamond surface and the positively charged GSSG in acidic media that promoted its analytical performance. The results of the electrolysis experiments of disulfides and thiols showed that the oxidation reaction mechanism of glutathione (GSH) and GSSG involves oxygen transfer. Following separation by liquid chromatography (LC), the determination of both GSH and GSSG in rat whole blood was achieved at a constant potential (1.50 V vs Ag/AgCl), and the limits of detection for GSH and GSSG were found to be 1.4 nM (0.028 pmol) and 1.9 nM (0.037 pmol) with a linear calibration range up to 0.25 mM. These detection limits were much lower than those reported for the amperometry using Bi-PbO2 electrodes and LC-mass spectrometry, and the LC method using diamond electrodes were comparable with enzymatic assay in real sample analysis. The high response stability and reproducibility together with the possibility of regeneration of the electrode surface by on-line anodic treatment at 3 V for 30 min further support the applicability of anodically pretreated diamond for amperometric detection of disulfides.

Journal Article↗

Electrochemical oxidation of underivatized-nucleic acids at highly boron-doped diamond electrodes.

Boron-doped diamond (BDD) electrodes have been examined for the electrochemical oxidation of underivatized-nucleic acids in terms of single stranded and double stranded DNA. Cyclic voltammetry and square wave voltammetry have been used to study the oxidation reactions and to detect DNA without derivatization or hydrolysis steps. At the diamond electrode, at least two well-defined voltammetric peaks were observed for both single stranded and double stranded DNA. Diamond electrode is the first material to show a well-defined voltammetric peaks for adenine group oxidation directly in the helix structure of nucleic acid due to its wide potential window. For single stranded DNA, a third peak, related to the pyrimidine group oxidation was also observed. As-deposited diamond film with predominantly hydrogen-terminated surface exhibited superior performance over oxygen-terminated diamond in terms of sensitivity. However, by optimizing the ionic strength, sensitivity of O-terminated films could be improved. Linear calibration results have shown linearity of current with concentration in the range 0.1-8 microg mL(-1) for both guanine and adenine residues at as-deposited BDD. Detection limits (S/N = 3) of 3.7 and 10 ng mL(-1) for adenine and guanine residue in single stranded DNA, respectively, and 5.2 and 10 ng mL(-1) for adenine and guanine residue in double stranded DNA, respectively, were observed. This work shows the promising use of diamond as an electrochemical detector for direct detection of nucleic acids. The results also show the possibility of using the oxidation peak current of adenine group that is more sensitive for the direct detection of nucleicacids.

Animals↗

Electrochemical detection of carbamate pesticides at conductive diamond electrodes.

Conductive boron-doped diamond thin-film electrodes were used for the electrochemical detection of selected N-methylcarbamate pesticides (carbaryl, carbofuran, methyl 2-benzimidazolecarbamate, bendiocarb) after liquid chromatographic separation. Two kinds of detection methods were adopted in this study. In the first method, a direct detection of underivatized pesticides was carried out at an operating potential of 1.45 V versus Ag/AgCl, which resulted in the detection limits of 5-20 ng/mL (or 5-20 ppb) with S/N = 2 due to the low background current and wide potential window of the diamond electrode. In the second method, the detection limits were improved by subjecting the pesticide samples to alkaline hydrolysis in a separate step prior to injection. The phenolic derivatives obtained by alkaline hydrolysis oxidize at a relatively lower potential (0.9 V vs Ag/AgCl), which increases the sensitivity drastically. The advantage of the diamond electrode for the detection of phenolic derivatives is that it offers excellent stability in comparison to other electrodes. This method gives the detection limits of 0.6-1 ng/mL (or 0.6-1 ppb), which are well below the maximum residue levels allowed for carbaryl, carbofuran, and bendiocarb. While the lowest detection limits (LOD) obtained by the direct detection of pesticides are comparable to the those reported by the well-established HPLC-fluorescence, the LODs of the alkaline hydrolysis method are found to be even lower than the reported limits. On-line reactivation of the diamond electrode surface was shown to be possible by an anodic treatment of the electrode at approximately 3 V for 30 min in case of electrode fouling, which may occur after a prolonged use. Such a treatment damages the glassy carbon (GC) and metal electrodes, while the diamond electrode remains stable. These results suggest that the diamond electrode is superior to the other previously used electrodes such as GC and Kelgraf type for highly sensitive and stable detection of carbamate pesticides.

Carbamates↗

Electrochemical oxidation of chlorophenols at a boron-doped diamond electrode and their determination by high-performance liquid chromatography with amperometric detection.

Anodically pretreated diamond electrodes have been used for the detection of chlorophenols (CPs) in environmental water samples after high-performance liquid chromatographic (HPLC) separation. The anodization of as-deposited boron-doped polycrystalline diamond thin-film electrodes has enabled the stable determination of phenols over a wide concentration range. Prior to the HPLC analysis, a comparative study with ordinary glassy carbon, as-deposited diamond, and anodized diamond was made to examine the oxidative behavior of phenols by cyclic voltammety and flow injection analysis with amperometric detection. At anodized diamond electrodes, reproducible, well-defined cyclic voltammograms were obtained even at high CP concentration (5 mM), due to a low proclivity for adsorption of the oxidation products on the surface. In addition, after prolonged use, the partially deactivated diamond could be reactivated on line by applying a highly anodic potential (2.64 Vvs SCE) for 4 min, which enabled the destruction of the electrodeposited polymer deposits. Hydroxyl radicals produced by the high applied potential, in which oxygen evolution occurs, are believed to be responsible for the oxidation of the passivating layer on the surface. When coupled with flow injection analysis (FIA), anodized diamond exhibited excellent stability, with a response variability of 2.3% (n = 100), for the oxidation of a high concentration (5 mM) of chlorophenol. In contrast, glassy carbon exhibited a response variability of 39.1%. After 100 injections, the relative peak intensity, for diamond decreased by 10%, while a drastic decrease of 70% was observed for glassy carbon. The detection limit obtained in the FIA mode for 2,4-dichlorophenol was found to be 20 nM (S/N = 3), with a linear dynamic range up to 100 microM. By coupling with the column-switching technique, which enabled on-line preconcentration (50 times), the detection limit was lowered to 0.4 nM (S/N = 3). By use of this technique, anodized diamond electrodes were demonstrated for the analysis of CPs in drainwater that was condensed from the flue gas of waste incinerators.

Boron↗

The electrochemical oxidation of homocysteine at boron-doped diamond electrodes with application to HPLC amperometric detection.

The electrochemical oxidation of homocysteine was studied at as-deposited and anodized (oxidized) boron-doped diamond (BDD) thin film electrodes with cyclic voltammetry, flow injection analysis and high-pressure liquid chromatography with amperometric detection. At anodized boron-doped diamond electrodes, highly reproducible, well-defined cyclic voltammograms for homocysteine oxidation were obtained in acidic media, while as-deposited diamond did not provide a detectable signal. In alkaline media, however, the oxidation response was obtained both at as-deposited and anodized diamond electrodes. The potential sweep rate dependence of homocysteine oxidation (peak currents for 1 mM homocysteine linearly proportional to v(1/2), within the range of 0.01 to 0.3 V s(-1)) indicates that the oxidation involves a diffusing species, with negligible adsorption on the BDD surface at this concentration. In the flow system, BDD exhibited a highly reproducible amperometric response, with a peak variation less than 2%. An extremely low detection limit (1 nM) was obtained at 1.6 V vs. Ag/AgCl. In addition, the determination of homocysteine in a standard mixture with aminothiols and disulfide compounds by means of isocratic reverse-phase HPLC with amperometric detection at diamond electrodes has been investigated. The results showed excellent separation, with a detection limit of 1 pmol and a linear range of three orders of magnitude.

Boron↗

Selective amperometric detection of dopamine using OPPy-modified diamond microsensor system.

Highly boron-doped diamond microfiber electrodes (BDDMF) were fabricated and characterized by the use of Scanning Electron Microscopy (SEM), Raman spectroscopy, and cyclic voltammetry. Amperometric detection of dopamine (DA), a neurotransmitter was achieved at pH 7.0, using BDDMF electrodes. The interferences from ascorbic acid (AA) and DOPAC were efficiently eliminated by using overoxidized polypyrrole-modified BDDMF electrodes, which also increased the sensitivity for the detection of dopamine. The limit of detection (S/N = 3) for dopamine was 0.1 nM, which is one order lower than that observed for carbon microfiber electrodes (CMFE), and the linear dynamic range was obtained from 0.5 nM to 100 microM (r2 = 0.997). The amperometric response for 0.5 nM dopamine has shown high stability with an RSD of 5.4% (n = 5). Highly reproducible results were obtained with an RSD of 6.2% for 10 measurements of 1 nM DA taken during 10 h and also remained the same, during measurements for 7 days, with no variation in efficiency for rejection of AA and DOPAC.

Cardiotonic Agents↗

Iron(III) spin-crossover compounds with a wide apparent thermal hysteresis around room temperature.

The magnetic properties of the spin-crossover compounds, [Fe(qsal)2]NCSe-MeOH (1) and [Fe(qsal)2]NCSe-CH2Cl2 (2), have been measured. We have discovered that both compounds 1 and 2 exhibit a wide thermal hysteresis loop of 140 K (T(1/2) upward arrow = 352 K and T(1/2) downward arrow = 212 K) and 180 K (T(1/2) upward arrow = 392 K and T(1/2) downward arrow = 212 K), respectively, in the first cycle. Thermogravimetric analysis shows that solvent molecules escape from compounds 1 and 2 around 340 and 395 K, respectively. This means that the hysteresis loops observed for the first cycle are only apparent ones. Following the first loop, they show a two-step spin-crossover in warming mode. The so-called "step 1" and "step 2" are centered around T(1/2(S1)) upward arrow = 215 K and T(1/2(S2)) upward arrow = 282 K, respectively. On the other hand, a one-step spin-crossover occurs at T(1/2) downward arrow = 212 K in cooling mode. The hysteresis widths can be estimated to be 3 K (step 1) and 70 K (step 2), assuming that the widths in steps 1 and 2 are defined as the differences between T(1/2(S1)) upward arrow and T(1/2) downward arrow, and T(1/2(S2)) upward arrow and T(1/2) downward arrow, respectively. The hysteresis width of 70 K in step 2 is one of the widest values reported so far for spin-crossover complexes. It is thought that the cooperativity operating in the complexes arises mainly from the intermolecular pi interactions between quinoline and phenyl rings. Using a previously reported model, we are able to simulate the hysteresis loop with a two-step spin-crossover in warming mode and a one-step transition in cooling mode.

Journal Article↗

Degradation of bisphenol A in water by TiO2 photocatalyst.

The photocatalytic degradation of bisphenol A (BPA), a representative endocrine disruptor, was carried out in TiO2 aqueous suspension. The main purposes were to confirm the total mineralization of BPA and to evaluate the estrogenic activity in the treated water during the photocatalytic reaction. An initial BPA concentration of 175 microM in water was totally degraded to carbon dioxide by TiO2-photocatalyzed reactions under UV irradiation of 10 mW cm-2 for 20 h. Four HPLC peaks indicating intermediate products appeared in chromatograms monitored at 275 nm, but the heights relative to that of the initial BPA were very low, at most 0.04 in the time period 5-10 h after the start of UV irradiation. All of the peaks finally disappeared after 20 h. For the treated water, the transcriptional estrogenic activity in response to human estrogen receptor in a yeast hybrid assay decreased drastically to less than 1% of the initial BPA's activity within 4 h. On the basis of these results, we conclude that TiO2 photocatalysis could be a useful technology for the purification of water containing BPA without generating any serious secondary pollution.

Benzhydryl Compounds↗

Voltammetric determination of L-cysteine at conductive diamond electrodes.

Boron-doped diamond (BDD) electrodes were used to examine L-cysteine (CySH) oxidation in alkaline media. The results of the voltammetric and polarization measurements showed that at BDD electrodes the overall CySH oxidation reaction is controlled by the initial electrochemical step, i.e., the oxidation of the CyS- electroactive species. The same conclusion was supported by the results of a study of pH effects. Conversely, at glassy carbon (GC) electrodes, the same reaction is controlled by the desorption of the reaction products. These results account for the poor response for CySH determination at GC compared to BDD. It was found that BDD exhibits excellent behavior for CySH determination, clearly outperforming GC. The results demonstrate that measurement of the peak current for CySH oxidation can be used as a basis for simple method for determining CySH in the micromolar concentration range by the use of BDD electrodes.

Cysteine↗

Characterization of the Chromophore Orientation of Rhodamine B Amphiphiles in Langmuir-Blodgett Monolayers.

SHG (second harmonic generation) interferometry and linear dichroism measurements were applied to the characterization of Langmuir-Blodgett monolayers composed of rhodamine B derivatives on hydrophilic fused silica substrates. When excited with a Nd-YAG laser, the contribution of dimeric species composed of rhodamine B chromophores to the nonlinear optical behavior was large, even though the relative concentration of the dimers was small. This implies the formation of noncentrosymmetrically oriented dimers with a relatively higher nonlinear molecular susceptibility, beta. Therefore, a unique phenomenon was observed; that is, the relative phase of the SH light shifted depending on the incident light polarization (p and s). In addition, it was found that the relatively standing up orientation was favored for the dimer, while a strongly tilted orientation was favored for the monomer. Copyright 2001 Academic Press.

Journal Article↗

Self-sterilizing and self-cleaning of silicone catheters coated with TiO(2) photocatalyst thin films: a preclinical work.

TiO(2) photocatalysts were successfully coated on silicone catheters or medical tubes by pretreatment of the silicone surface with a sulfuric acid solution (5 M) for 3 h. The TiO(2) film adhered to the silicone substrate strongly against tensile and bending stresses. On the TiO(2)-coated silicone-catheters under UV illumination, both the bleaching of methylene blue dye and the photocatalytic bactericidal effect on Escherichia coli (E. coli) cells were confirmed. Thus, this type of catheter can be sterilized and cleaned simply by irradiation with low-intensity UV light and can, therefore, be useful in the protection from catheter-related bacterial infections.

Coated Materials, Biocompatible↗

Preventive effect of tooth fracture by pulsed Nd:YAG laser irradiation with diamine silver fluoride solution.

OBJECTIVE: The purpose of the present study was to evaluate the preventive effect of pulsed Nd:YAG laser irradiation with 38% diamine silver fluoride [Ag(NH3)2F] solution for the fracture of endodontically treated teeth in vitro. BACKGROUND DATA: There have been no reports on the preventive effect of tooth fracture using Nd:YAG laser with Ag(NH3)2F solution. MATERIALS AND METHODS: Twenty-eight human extracted teeth were used in this study. The teeth were randomly classified into four groups: control group, where tooth surfaces were not submitted to any treatment; group 1, where tooth surfaces were coated with 38% Ag(NH3)2F solution; group 2, where tooth surfaces were coated with Ag(NH3)2F solution and irradiated by pulsed Nd:YAG laser for 2 sec; and group 3, where tooth surfaces were coated with Ag(NH3)2F solution and irradiated by pulsed Nd:YAG laser for 10 sec. After preparation, shear tests were performed and the maximum load for the fracture was measured. Results were analyzed using the Scheffe test, and difference at p < 0.05 was considered significant. RESULTS: The failure load for group 2 (mean, 182.5 kg) had the highest mean value and differed significantly from those for the control group (mean, 146.3 kg) and group 1 (mean, 147.1 kg; p < 0.05). The failure loads for groups 1 and 3 (mean, 150.0 kg) did not differ significantly from that for the control group (p > 0.05). CONCLUSION: The results show that the application of 38% Ag(NH3)2F solution followed by pulsed Nd:YAG laser irradiation for 2 sec is useful for prevention of tooth fracture at endodontically treated teeth.

Fluorides, Topical↗