PubMed Health⌕ Search

Biomedical subjects

A Furuse

Publications and source records attributed to A Furuse.

At least 19 recordsLinked to original sources

[Aortic valve replacement in a renal transplant recipient].

A 65-year-old male was admitted to our hospital for surgical treatment of congestive heart failure with aortic regurgitation. He had received renal transplantation 15 years before in the United States, and had been under immunosuppressive regimen with ciclosporin and mycophenolate mofetil. Although the renal allograft function had been gradually deteriorating, and preoperative serum creatinine level was 1.8 mg/dl, and it decreased to 1.5 mg/dl after aortic valve replacement. Cryopreserved aortic allograft was needed for the aortic valve replacement. The reasons are; the patient may need hemodialysis (HD) or retransplantation of the kidney in the future, and the immunosuppressive therapy for kidney will provide good immunologic environment for second allograft, i.e.--aortic valve. He tolerated the operation well and the immunosuppressive agents were continued in the perioperative period. He is now in New York Heart Association (NYHA) class I.

Aged↗

[Secondary left main trunk coronary artery shock syndrome].

A 71-year-old male patient was admitted to our hospital and diagnosed as inferior wall acute myocardial infarction (AMI). Coronary angiogram revealed 3 vessel disease and left main trunk coronary artery (LMT) lesion. Because right coronary artery (RCA) had been recanalised, he was scheduled to operation. On the 6th day after admission, another attack made him fell into secondary LMT shock syndrome and lung edema. Emergency operation was performed and he recovered from heart failure. Here we report the case and added some considerations.

Aged↗

'No-Touch' isolation procedure for ruptured mycotic abdominal aortic aneurysm.

The present study reports a case of the successful surgical repair of a ruptured infra-renal mycotic abdominal aorta with Enterobactor cloacae in a 66-year-old man. During the operative procedure, an extra-anatomic bypass was installed before the laparotomy in order to avoid bacterial contamination. A complete resection of the infected aorta, tapering of the arterial stumps, wrapping of the omentum, and ligation of the aorta and arteries with Teflon tapes was carried out. The patient is alive and well 1 year postsurgery.

Aged↗

[What we must learn from recent medical accidents--experiences at the investigation committee].

The current publicity of medical accidents in Japan started with two well-known accidents. On January 11, 1999, a cardiac patient underwent a pulmonary operation, while a pulmonary patient received cardiac surgery at Yokohama City University Hospital. On February 11, 1999, detergent was inadvertently injected into a venous line at Hiroo Hospital in Tokyo. The author was invited as an indifferent specialist to serve on the Investigation Committee for these two accidents. This article describes the lessons to be learned from these two accidents.

Drug Labeling↗

Experimental study of small arterial anastomosis with gelatin-resorcin-formaldehyde glue and collagen sheet.

In cardiovascular surgery, the manual continuous suture has often been used for microvascular anastomosis, but the luminal irregularity often causes thrombotic stenosis in the anastomosis sites. The purpose of this study was to examine the feasibility of the combined use of gelatin-resorcin-formaldehyde (GRF) glue and a collagen sheet for the anastomosis of small arteries 3 to 4 mm in diameter in experimental animals. End-to-end anastomoses of the carotid and femoral arteries of mongrel dogs were carried out with the combined use of GRF glue and collagen sheet. The physical strength of the anastomosis, the histopathologic condition of the vassels, and the absorptivity and the inflammatory response of the glue were evaluated. The physical strength of the anastomosis sites was good and their flexibility optimal, the smooth luminal surface appeared excellent for preventing thrombotic stenosis in all follow-up periods, and the glue was absorbed almost completely within 12 weeks postoperatively. The combined use of GRF glue and collagen sheet would be feasible for the anastomosis of small arteries 3 to 4 mm in diameter and could substitute for the conventional suture method.

Anastomosis, Surgical↗

Favorable results in patients with small size CarboMedics heart valves in the aortic position.

Hemodynamic performance of the CarboMedics heart valve in the aortic position and its clinical impacts were investigated in 126 consecutive patients. The actuarial survival rates of patients who had undergone isolated aortic valve replacement and concomitant aortic and mitral valve replacement were 82.6+/-5.7% and 71.0+/-9.2% at 8 years, respectively. Morbid events were rare, and almost all late survivors were free from evident cardiac symptoms regardless of the valve size. Echocardiography revealed suboptimal transvalvular pressure gradients and effective orifice areas of 19 mm and 21 mm valves. However, relief of the left ventricular overload and improvement of the clinical symptoms as well as cardiac function were comparable to those of patients with larger valves. Valve function measured by echocardiography did not show significant correlation to late outcome. Good results can be expected even in the presence of echocardiographic data such as peak pressure gradient over 40 mmHg, effective orifice area less than 1.0 cm(2), and effective orifice area index less than 0.7 cm(2)/m(2).

Adolescent↗

[Notification of unexpected patients' death to the police].

Controversies continue to exist in what situation the surgeons are obliged to report the perioperative patients' death to the police. With regard to this issue, Japan Surgical Society and twelve other Japanese Surgical Societies have declared that 1) patients' death due to evident malpractice must be reported to the police, 2) patients' death resulting from anticipated surgical complications need not be reported to the police, 3) an independent organization be founded for collection and investigation of medical accident/incident reports. Japan Surgical Society will take a responsibility of making a practical guideline as to the notification of accidents to the police and take a leadership in establishing the independent medical accident/incident center.

Aged↗

Effects of recombinant human erythropoietin therapy on blood coagulation and fibrinolysis system.

This study was designed to examine the effects of recombinant human erythropoietin (rHuEPO) therapy on blood coagulation and fibrinolysis in patients scheduled for elective heart surgery and undergoing preoperative autologous blood donation. Twenty-seven patients were studied, of whom 16 patients received rHuEPO (group E) and 11 patients no rHuEPO therapy (group N). The patients in group E were given 6000 units of rHuEPO intravenously every other day, three times a week, beginning from two weeks prior to the operation. In both groups, 400 ml of blood was collected preoperatively for predeposit once a week for two weeks, and the self-donated blood was returned to the patient intra- and postoperatively. Blood samples were drawn at the beginning of the study, immediately before the operation and two weeks after the operation. They were analyzed to assess blood coagulation, fibrinolysis, platelet function and vascular endothelial cell function, in order to examine the effects of the administration of rHuEPO. No significant difference was observed between the two groups in the degree of changes in these parameters following the operation. As enhancement of blood coagulability and fibrinolytic activity was evident postoperatively in both groups, changes in these parameters during the preoperative autologous blood donation period were also assessed excluding the postoperative data. Again, there was no significant intergroup difference in any of the markers evaluated. It was concluded that the administration of rHuEPO during preoperative autologous blood donation is unlikely to affect coagulation and fibrinolysis.

Adult↗

Cardiac function evaluated by transesophageal echocardiography during cardiopulmonary bypass.

OBJECTIVE: To evaluate cardiac function at cardiopulmonary bypass weaning, we applied a new technique clinically to determine the approximated Emax without using a conductance catheter. METHODS: Subjects were 5 patients. The left ventricular end-systolic pressure was obtained by overlaying the radial arterial pressure curve on the left ventricular pressure curve. Left ventricular end-systolic volume was assessed by a transesophageal echographic apparatus. At cardiopulmonary bypass weaning, volume loading was applied to increase left atrial pressure by a few mmHg while fixing the pump flow rate at half flow. Changes in left ventricular end-systolic volume and approximated left ventricular end-systolic pressure for total heart beat were plotted during this period, and the gradient of the regression line was taken as approximated Emax. RESULTS: Approximated Emax ranged from 1.29 to 3.28 (mean 2.13 +/- 0.72), and its correlation coefficient was 0.80 +/- 0.06. CONCLUSION: Our new technique is useful in evaluating cardiac function during cardiopulmonary bypass.

Adult↗

Systemic-to-pulmonary shunt in a patient with isolation of the subclavian artery.

A surgical procedure is described that was carried out to treat an 18-month-old boy with tetralogy of Fallot, right aortic arch, and isolation of the left subclavian artery. The patient underwent a descending aorta-right pulmonary artery shunt using a polytetrafluoroethylene graft, as a systemic-pulmonary shunt. The effectiveness of this procedure in patients with some special conditions is discussed.

Abnormalities, Multiple↗

Atrial ablation using an IRK-151 infrared coagulator in canine model.

BACKGROUND: A method of atrial ablation was developed with the aim of shortening the aortic cross-clamp time during MAZE surgery. The IRK-151 infrared coagulator (Infrarot-Kontaktkoagulator: MBB: Messerschmidt-Bolkow-Blohn, Germany) was employed. Our aim was to electrophysiologically confirm the efficacy of this device. METHODS: The MAZE-III procedure was performed in four mongrel dogs. Instead of a pulmonary vein-encircling incision, IRK-151 was applied several times to create a continuously overlapping circular lesion. After aortic declamping, the potentials of both atria were recorded using 18 bipolar electrodes implanted in the atrial wall. The recording conditions were: 1) sinus rhythm, 2) overdrive pacing from outside the encircling coagulation, and 3) overdrive pacing from inside the encircling coagulation. RESULTS: 1) There was no detectable potential within the pulmonary vein-encircling coagulation. 2) There was no conduction of paced atrial potential inside the encircling coagulation. 3) Only the area within the encircling coagulation was activated by the stimulus. Other parts of the atrium showed sinus rhythm simultaneously. CONCLUSIONS: The left atrium within the pulmonary vein-encircling coagulation was isolated electrophysiologically.

Animals↗

Are Metallic Markers Necessary for Coronary Artery Bypass Grafts? A Study Using X-ray Computed Tomography and Selective Graft Angiography.

Using X-ray computed tomography (CT) and selective graft angiography, the authors studied the necessity of metallic markers in coronary artery bypass grafts on 45 patients (mean age 57.2 years) with 87 saphenous vein grafts. Eight patients had 17 markers. X-ray CT was performed after surgery using an apparatus with a 1-second scanning time. Noncontrast X-ray CT was performed on horizontal sections, at 5-mm intervals, from the lower margin of the aortic arch to the lower left ventricle. A contrast medium was then injected into the antecubital vein (3 ml/second, total 30 ml) in one cross-section at the level of bifurcation of the pulmonary artery. Aortography (60 degrees in the left anterior and oblique positions, 20 ml/second, total 40 ml) was performed concurrently. Selective graft angiography was taken in the same direction, using 4 cm right of the Judkins with reference to the aortographic image and position of five clips on the sternum. Aortography revealed 79 patent and 8 occluded grafts. Selective graft angiography was easily performed even in grafts without markers. A cross-section of the occluded graft could not be seen with X-ray CT. Grafts with markers were often masked by artifacts produced by markers on X-ray CT. The number of observed graft slices (marker-positive grafts) was only 1.2 +/- 1.1 slices, significantly (p < 0.01) lower than marker-negative grafts (4.1 +/- 3.1 slices). In particular, the number of marker-positive right coronary artery grafts was 0.4 +/- 0.9 slices. Four of five right coronary artery grafts were unobservable due to artifacts. In grafts without markers, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of X-ray CT to graft patency were 100%, 85.7%, 98.4%, 100%, and 98.6%, respectively. This study suggests that metallic markers may not be necessary for coronary artery bypass grafts.

Journal Article↗

Management of severe acute pancreatitis with a somatostatin analog in a patient undergoing surgery for dissecting thoracic aneurysm: report of a case.

A patient who was admitted to our hospital to undergo surgery for a dissecting thoracic aneurysm suffered preoperatively from severe acute pancreatitis with pancreatic pseudocysts. Computerized tomography (CT) demonstrated the presence of new fluid collection around the cyst with the absence of pancreatic necrosis. He was given a somatostatin analog (sandostatin), which was effective in decreasing the abdominal symptoms, leukocyte counts, and the serum C-reactive/protein level. A CT scan revealed that the pancreatic pseudocyst and peripancreatic fluid collection had disappeared. Although somatostatin has been reported to be ineffective for acute pancreatitis with necrosis, pancreatitis without necrosis may regress after treatment with sandostatin. This is probably due to its suppressive effect on the exocrine function, thus resulting in a decrease of pancreatic juice infiltration.

Acute Disease↗

Transthoracoscopic needle biopsy for indeterminate lung nodules.

BACKGROUND: The usefulness of transthoracoscopic needle biopsy for preoperatively indeterminate intrapulmonary nodules was evaluated. METHODS: Thoracoscopy was performed on 38 patients with pulmonary solitary nodules suspected to be primary lung carcinomas. When the nodule was localized by simple observation or tactile sensor, a biopsy specimen of the tumor was obtained by a biopsy needle introduced through a trocar. RESULTS: The nodules were 7 to 55 mm in diameter. All were located in the peripheral region of the lung. Biopsy specimens were obtained even from 17 nodules with no associated pleural changes. By cytology, all the malignant tumors were precisely diagnosed, 29 as primary lung cancers and 3 as metastatic lung neoplasms. Five of the remaining six benign nodules were not precisely diagnosed. However, they were cytologically classified as class I. CONCLUSIONS: Transthoracoscopic needle biopsy is feasible for diagnosing small intrapulmonary nodules, particularly those of malignant neoplasms. As compared with thoracoscopic excisional biopsy, transthoracoscopic needle biopsy saves time and may reduce the possibility of tumor dissemination during the procedure.

Adult↗

Intravalvular implantation technique for aortic valve replacement in aortitis syndrome.

BACKGROUND: Paravalvular leakage is one of the most serious complications of aortic valve replacement in patients with aortitis syndrome. The purpose of this study was to compare the effectiveness of the intravalvular implantation technique in preventing paravalvular leakage with that of the conventional technique. METHODS: Since 1982, 14 patients with aortic regurgitation caused by aortitis syndrome have undergone aortic valve replacement at our institute. An intravalvular implantation technique was applied in 7 of the 14 patients. The technique consists of suturing a prosthetic valve to the aortic annulus and sandwiching the leaflets between exogenous felt pledgets and the inflamed aortic annulus. RESULTS: Paravalvular leakage occurred in 3 of 7 patients in the conventionally treated group and in none of 7 in the intravalvular implantation group. CONCLUSIONS: The intravalvular implantation technique is effective in preventing paravalvular leakage in patients with aortitis syndrome.

Adult↗