Quantification of pyuria by two methods correlation and interobserver agreement.

The aim of this study was to correlate the results of two methods of quantifying pyuria and to compare the diagnostic reliability of the two methods in terms of interobserver agreement. Three independent observers counted leucocytes in 56 urine samples by using high-power-field (HPF) microscopy on centrifuged urine sediment and by using a Bürker haemocytometer on uncentrifuged urine. The commonly accepted diagnostic level of ten leucocytes/mm3 in the haemocytometer was found to be equivalent to two leucocytes/HPF. This agrees with other reports but contrasts with the usual notion of a diagnostic level of five to ten leucocytes/HPF, and implies that urinary tract infection in the presence of symptoms should not be ruled out when less than five leucocytes/HPF are found. Kappa statistics were used to evaluate the interobserver agreement. The observers agreed on the diagnosis in 96% (K = 0.92) of the urines when the haemocytometer was used, and in 93-96% (K = 0.81-K = 0.91) when leucocytes were counted per HPF. The differences in Kappa values were not statistically significant. Our material indicates that the method of quantifying pyuria in centrifuged urine sediment by HPF microscopy may be used as the routine method in general practice.

Humans↗

Stability of haematological constituents during simulated mail transport as measured by Coulter Counter S plus II or Technicon H 6000.

Stability of blood constituents after mail transport was examined using two different automated haematology instruments, that is, Coulter Counter S plus II and Technicon H 6000. The results were analysed by two different statistical methods. In all but four cases these methods yielded similar results. The B-LPC, B-EPC B-Hb, B-EVF, E-MCH, E-MCHC and B-TPC were stable after mail transport for 48 h when measured with Coulter Counter S plus II. In contrast, none of these parameters were stable when measured with Technicon H 6000. The differential count measured by cytochemical staining technique with Technicon H 6000 was stable for 72 h whereas the percentage of L-Lymphocytes measured with Coulter Counter S plus II was unstable after 24 h of mail transport. The criteria of stability are discussed in relation to changes of constituents that are of importance in medical decision making.

Autoanalysis↗