Time and motion study: a comparison of two photostimulable phosphor imaging systems used in dentistry.

OBJECTIVES: To compare two photostimulable phosphor (PSP) dental radiographic systems in terms of time efficiency in making full mouth intraoral X-ray surveys (FMS). METHODS: PSP systems compared were (1) DenOptix) (Kavo/Gendex, Des Plaines, IL) and (2) ScanX) (Air Techniques, Hicksville, NY). Twenty one FMS of a DXTRR) Manikin (Dentsply, Des Plaines, IL) were made with each of the systems. Time for each procedural step was determined using a stopwatch. Steps studied were: (1) plate erasure; (2) packaging; (3) positioning/exposure; (4) unpacking, loading processor, scanning; and (5) image transfer to virtual FMS mount. The first six test runs for each system were excluded to eliminate the learning curve period influencing results. An independent groups t-test was employed for statistical analysis. The a priori was set at P< or =0.05. RESULTS: The total time involved in producing a FMS was not proven to be statistically significant comparing DenOptix) and ScanX). The mean procedure time for DenOptix) was 31.2 min; for ScanX) it was 27.1 min. While the processing time with ScanX) (mean time: 3.9 min) was shorter than for DenOptix) (mean time =7.8 min), the opposite was true for the image transfer to FMS format with the time much shorter with DenOptix) using VixWin) software (mean time =2.0 min) compared with ScanX) using Vipersoft) (mean time =3.9 min). The differences between the systems for these two steps did prove to be statistically significant (P< or =0.05). CONCLUSIONS: Although the mean time to make a FMS was slightly shorter on average with ScanX) than DenOptix), this difference was not proven to be statistically significant (P>0.05) in terms of time efficiency in producing a FMS.

Humans↗

Antibiotic use for irreversible pulpitis.

BACKGROUND: Irreversible pulpitis, which is characterised by acute and intense pain, is one of the most frequent reasons that patients attend for emergency dental care. Apart from removal of the tooth the customary way of relieving the pain of irreversible pulpitis is by drilling into the tooth, removing the inflamed pulp (nerve) and cleaning the root canal. However, a significant minority of dentists continue to prescribe antibiotics to stop the pain of irreversible pulpitis. OBJECTIVES: The objective of this review was to provide reliable evidence regarding the effectiveness of prescribing systemic antibiotics for irreversible pulpitis by comparing clinical outcomes expressed as pain relief. SEARCH STRATEGY: We searched the following databases: Cochrane Oral Health Group Trials Register and Pain, Palliative Care and Supportive (PaPaS) Care Group Trials Register to 6th September 2004; the Cochrane Central Register of Controlled Trials (CENTRAL) The Cochrane Library Issue 3 2004; MEDLINE (1966 to 6th September 2004); EMBASE (1980 to week 36 2004). SELECTION CRITERIA: This review includes one randomised controlled trial which compared pain relief with systemic antibiotics and analgesics, against placebo and analgesics in the acute preoperative phase of irreversible pulpitis. DATA COLLECTION AND ANALYSIS: Only one trial is included in this review, therefore pooling of data from studies was not possible and a descriptive summary is presented. MAIN RESULTS: One trial involving 40 participants was included in this review. There was a close parallel distribution of the pain ratings in both the intervention and placebo groups over the 7 day study period. The between-group differences in sum pain intensity differences (SPID) for the penicillin group were (6.0+/-10.5), and for placebo (6.0+/-9.5) P = 0.776. The sum pain percussion intensity differences (SPPID) for the penicillin group were (3.5+/-7.5) and placebo (2.0+/-7.0) P = 0.290, with differences as assessed by the Mann-Whitney-Wilcoxon test considered to be statistically significant at P < 0.05. There was no significant difference in the mean total number of ibuprofen tablets (P = 0.839) and Tylenol tablets (P = 0.325), in either group over the study period. The administration of penicillin over placebo did not appear to significantly reduce the quantity of analgesic medication taken (P > 0.05) for irreversible pulpitis. AUTHORS' CONCLUSIONS: This review which was based on one methodologically sound but low powered small sample trial provided some evidence that there is no significant difference in pain relief for patients with untreated irreversible pulpitis who did or did not receive antibiotics in addition to analgesics.

Analgesics↗

Array geometry for assessment of mandibular implant position using tuned aperture computed tomography (TACT).

OBJECTIVE: To evaluate observer faciolingual depth and vertical depth reading errors when using various X-ray beam array geometries to make basis images for tomosynthetic reconstruction using tuned aperture computed tomography (TACT). MATERIALS AND METHODS: Tissue-equivalent models were constructed to replicate the position of dental implants in relation to simulated mandibular canals. X-ray beam geometries used to acquire the basis images for TACT(TM) integration included horizontal linear, vertical linear, and symmetric and asymmetric conical arrays. Twenty-one dentists trained in the use of TACT acted independently as observers. Tasks included: (1) determination of the relative position of the implant in relation to the simulated canal; and (2) measurement of the vertical depth and faciolingual (lateral) depth dimensions between these two structures. As the study did not involve repeated measures (only one measure was obtained from each observer on each of the two dependent variables), data for faciolingual depth and vertical depth reading errors were analysed using a one-way analysis of variance (ANOVA) with Tukey's honestly significant different (HSD) procedure. RESULTS: Errors in determining the relative position of the implant to the simulated canal were most frequent when the linear horizontal projection geometry was employed for producing basis images (57% error for model #2 where the implant was lingually placed). The mean measurement errors for TACT images constructed using the various different projection arrays depended both on the structural relationship of anatomic features and the employed beam array geometry. CONCLUSION: Conical beam arrays are preferred over linear beam arrays for constructing basis images used with TACT for the purpose of correlating the position of a mandibular dental implant in relation to the mandibular canal. They more consistently allowed the observers to establish a measurement of the faciolingual relationship of the implant to the canal. For vertical depth measurement of the relationship of a mandibular dental implant to the mandibular canal, TACT does not appear to have any advantage over individual simple transmission radiographic images.

Analysis of Variance↗

Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector.

OBJECTIVE: To evaluate the signal-to-noise ratio (SNR) of the Dexis charge-coupled device (CCD) intraoral X-ray detector, with special reference to the influence of beam energy and filtration. MATERIAL AND METHODS: Digital radiographic images were made of a nine-step dental aluminium step wedge using a Dexis intraoral detector. The X-ray generator was a GE 1000 operating at 10 mA with 2.7 mm aluminium filtration. The peak tube voltage settings applied were 50 kVp, 60 kVp, 70 kVp, 80 kVp and 90 kVp. Various exposure times were used at each beam energy and the exposures (in micro C kg(-1)) were determined in each case using a 3 cl beryllium-windowed ionization chamber. SNR was defined using the surrogate measure of mean pixel value (surrogate for signal) divided by the standard deviation of the pixel value (surrogate for noise). SNRs were measured at separate regions of interest (ROIs) at the centre and at both sides of the detector for each aluminium step as well as without the step. RESULTS: For beam energies of 50 kVp and 60 kVp, the estimated SNR improved both with increased exposure and with increased filtration (thickness of the aluminium step), and image saturation did not occur within the exposure time range permitted by the Dexis software. At 70 kVp and above, the SNR was optimized in the middle of the exposure range: 4 micro C kg(-1) with 290:1 at the ninth step (13.5 mm Al) for 70 kVp; 3.5 micro C kg(-1) with 240:1 at the ninth step (13.5 mm Al) for 80 kVp; 3.5 micro C kg(-1) with 160:1 at the ninth step (13.5 mm Al) for 90 kVp. Saturation did occur at these beam energies within the exposure time range permitted by the Dexis software. CONCLUSION: For the Dexis intraoral radiographic imaging system, estimated SNR improved both with higher filtration and with lower kVp. The Dexis detector was capable of generating acceptable images of the step wedge at a wide range of kVp settings.

Aluminum↗

Impact of ambient lighting intensity and duration on the signal-to-noise ratio of images from photostimulable phosphor plates processed using DenOptix and ScanX systems.

OBJECTIVES: To evaluate the impact on photostimulable phosphor (PSP) image signal-to-noise ratio (SNR) of pre-scanning ambient lighting exposures. METHOD: PSP imaging plates (IPs) were exposed to different radiation exposures to achieve flat field images. The exposed IPs were subjected variously to visible light of different intensities (300, 150 or 20 lux) for durations ranging from < 10 s to 120 s. They were processed using laser scanners from two systems for further comparison (DenOptix versus ScanX). Histogram analysis was performed in each case and mean pixel value and its standard deviation were used as surrogates to assess SNR. Statistical methods applied included analysis of variance with Tukey honestly significant difference test for pair wise comparisons. The a priori alpha was set at P < or = 0.05. RESULTS: SNR decreased with increased duration and intensity of pre-scanning light exposure. Lower X-ray exposures resulted in decreased signal resulting in reduced SNR, and increased the need to reduce ambient lighting. No statistically significant differences were found comparing ScanX and DenOptix digital imaging systems in terms of SNR. CONCLUSION: Reduced ambient lighting is preferred for handling IPs prior to processing in the laser scanner.

Artifacts↗

Fundamentals of image acquisition and processing in the digital era.

OBJECTIVES: To review the historic context for digital imaging in dentistry and to outline the fundamental issues related to digital imaging modalities. CONTEXT: Digital dental X-ray images can be achieved by scanning analog film radiographs (secondary capture), with photostimulable phosphors, or using solid-state detectors (e.g. charge-coupled device and complementary metal oxide semiconductor). There are four characteristics that are basic to all digital image detectors; namely, size of active area, signal-to-noise ratio, contrast resolution and the spatial resolution. To perceive structure in a radiographic image, there needs to be sufficient difference between contrasting densities. This primarily depends on the differences in the attenuation of the X-ray beam by adjacent tissues. It is also depends on the signal received; therefore, contrast tends to increase with increased exposure. Given adequate signal and sufficient differences in radiodensity, contrast will be sufficient to differentiate between adjacent structures, irrespective of the recording modality and processing used. Where contrast is not sufficient, digital images can sometimes be post-processed to disclose details that would otherwise go undetected. For example, cephalogram isodensity mapping can improve soft tissue detail. CONCLUSIONS: It is concluded that it could be a further decade or two before three-dimensional digital imaging systems entirely replace two-dimensional analog films. Such systems need not only to produce prettier images, but also to provide a demonstrable evidence-based higher standard of care at a cost that is not economically prohibitive for the practitioner or society, and which allows efficient and effective workflow within the business of dental practice.

History, 20th Century↗

Image file interoperability for data protection, communication and trans-system connectivity.

DICOM (Digital Imaging and Communication in Medicine) is a set of international imaging standards developed for medicine and extended to incorporate other professions. These standards encompass primary digital and secondary capture images made for dental diagnostic procedures. The standards provide a basis of interoperability for digital system outputs, providing portability and reducing the danger of obsolescence that would render valuable diagnostic information impossible to display. The American Dental Association, through the activities of its Working Group 12.1, is promoting interoperability within DICOM as the industry standard for digital imaging in dentistry.

Computer Communication Networks↗

Comparison of complementary metal oxide semiconductor and charge-coupled device intraoral X-ray detectors using subjective image quality.

OBJECTIVE: To compare the subjective image quality of the newer generation Schick CDR detector employing complementary metal oxide semiconductor (CMOS) technology with images using the earlier generation charge-coupled device (CCD) Schick CDR detector. METHODS: All radiographic images were made using the same formalin-fixed adult cadaver maxilla with surrounding natural soft tissues in place. The X-ray generator used was a Villa Sistemi Medicali Diamatic srl AP/Explor X operated at 70 kVp and 8 mA. The source-to-detector distance was set at 38 cm and an optical bench was used to ensure reproducible beam geometry. A range of exposures was applied for both detectors. A panel of nine dentists independently observed and evaluated images made at each exposure. For both detectors, the three images ranked highest were randomized for re-evaluation in panels of six images. Each image was repeated randomly a total of 10 times. Features chosen as observation points were: (1) proximal dental caries; (2) gingival soft tissues; (3) cortical bone; (4) root canal space; (5) root apices; (6) periodontal ligament space; and (7) endodontic instrument tip clarity. Comparisons were made by use of odds ratio analysis applying a 95% confidence level. Interrater and intrarater reliabilities were computed to assess consistency in observer ratings. RESULTS: The CMOS sensor was rated as outperforming its CCD predecessor for depiction of cortical bone and root apices; the CCD detector was only rated superior for depiction of root canal space. No significant difference was found between the two detectors in perceived depiction of proximal dental caries, gingival soft tissues, periodontal ligament space or endodontic instruments. Combining rating scores from each of the tasks, CMOS and CCD detectors had a similar proportion of image ratings of excellent, acceptable and poor. CONCLUSIONS: Regarding subjective image quality, the Schick CMOS and CCD detectors were perceived to produce radiographic images of similar overall quality.

Adult↗

Outcomes of digital X-ray mini-panel examinations for patients having mental retardation and developmental disability.

OBJECTIVES: Severely and profoundly mentally retarded and developmentally disabled (MR/DD) patients are unable to communicate disease symptoms, and radiographic examinations are often difficult to perform on non-sedated patients. This clinical trial evaluated the impact on dental treatment planning of radiographic mini-panels for MR/DD patients. METHODS: With Institutional Review Board approval and informed consent of the legal guardian of each patient, a digital series of six periapical radiographs was achieved without sedation on 72 MR/DD inpatients (the survey was attempted on 74 patients). RESULTS: The average number of teeth included in each mini-panel was 20.4 compared with 22.2 teeth found clinically and 22.7 teeth determined combining both clinical and radiographic findings. Individual mini-panel images were judged technically excellent in 65% of cases, diagnostically satisfactory in 26% of cases and suboptimal in 9%. The radiographic panels were judged to affect treatment planning for more than 60% of the patients included in the trial. In 32% the detected condition was one or more periapical radiolucency. Several radiographic findings indicated potentially painful conditions that perhaps explained patient actions previously attributed to behavioural problems. Potential sources of dental pain and sepsis were treated by endodontic therapy or dental extractions on a case-by-case basis with or without general anesthesia. The trial also demonstrated a need that has translated into increased state allocations for dental treatment of MR/DD patients resident in the Commonwealth of Kentucky. CONCLUSIONS: Dental inspections of MR/DD patients are incomplete if radiographs are excluded. Whilst the mini-panel approach could be considered incomplete, it is better than no radiographs at all. 91% of images were excellent to satisfactory in diagnostic quality and a majority of patients' treatments were modified because of the radiographic information.

Child↗

A sequential approach to radiological interpretation.

A case of large glandular odontogenic cyst of the mandible is presented in which the panoramic radiograph also demonstrated a soft tissue lesion consistent with carotid aneurysm. CT confirmed the bucco-lingual extent of the mandibular lesion and the presence of a soft tissue lesion consistent with an aneurysm of the internal carotid artery. CT angiography, MR angiography and US were used to rule out a carotid artery aneurysm prior to surgery of the mandibular lesion.

Aged↗

A comparison of image characteristics and convenience in panoramic radiography using charge-coupled device, storage phosphor, and film receptors.

This study compared the image layer characteristics, dose requirements, and convenience in use of panoramic radiography using each of four different image receptors including traditional indirect exposure x-ray film, a storage phosphor system, and two solid-state sensors. The OP 100 D (Instrumentarium Imaging, Tuusula, Finland) charge-coupled device (CCD) sensor provided an instant image with a wide focal trough, making patient positioning error unlikely, but at the same time required a patient dose higher than that used with film. While the DigiPan (Trex/Trophy, Marne-la-Vallée, France) CCD significantly reduced the patient dose to radiation and also provided an instant image, the focal trough was narrower making patient positioning error more likely. The storage phosphor system provided high resolution and a reasonable focal trough width, but the procedure took longer than traditional film radiography and did not provide a dose saving.

Humans↗

Sensitometric properties of Agfa Dentus OrthoLux, Agfa Dentus ST8G, and Kodak Ektavision panoramic radiographic film.

OBJECTIVES: The purpose of this study was to compare the sensitometric properties of and visualization of anatomical structures with Agfa OrthoLux green-sensitive panoramic radiographic film, Agfa ST8G green sensitive panoramic radiographic film, and Kodak Ektavision green-sensitive panoramic radiographic film used in combination with an Agfa Ortho Regular 400 imaging screen, Kodak Ektavision imaging screen, and Kodak Lanex Regular imaging screen. METHODS: The density response and resolution of panoramic radiographic film/intensifying screen combinations was evaluated by means of Hunter and Driffield curves, modulation transfer functions, and noise-equivalent number of quanta. Image clarity of selected anatomical structures was rated independently by 6 oral and maxillofacial radiologists. RESULTS: The ISO speed for the Agfa OrthoLux panoramic radiographic film combinations was the fastest, and the ISO speed for the Kodak Ektavision green-sensitive panoramic radiographic film combinations was the slowest. The average gradient for the Agfa ST8G systems was relatively steep in comparison with those for the other film/screen combinations. The modulation transfer functions for the Kodak Ektavision film were higher than those for the other films, irrespective of the screen combination used, and those for Agfa OrthoLux film were slightly higher than those for Agfa ST8G film. The noise-equivalent number of quanta for the Agfa ST8G film/screen combinations was lower than those for the other film/screen combinations. The noise-equivalent number of quanta for the Kodak Ektavision film/screen combinations was well within the high-frequency range, whereas Agfa OrthoLux combined with either the Kodak Ektavision imaging screen or the Kodak Lanex Regular imaging screen produced a noise-equivalent number of quanta similar to those of the Kodak Ektavision film/screen combinations in the low-frequency range. Agfa OrthoLux was perceived to provide clearer images of the selected anatomical details than Agfa ST8G, and the Agfa OrthoLux/Agfa Ortho Regular 400 combination was not significantly different from the Kodak Ektavision/Kodak Lanex Regular combination in terms of perceived image quality. CONCLUSION: Agfa OrthoLux is an improvement over Agfa ST8G in film speed, spatial resolution, granularity, and perceived diagnostic image quality. The Agfa OrthoLux/Agfa Ortho Regular 400 combination did not exceed the Kodak Ektavision film/Kodak Ektavision imaging screen combination in resolution, granularity, or perceived image quality.

Algorithms↗

Array-projection geometry and depth discrimination with Tuned-Aperture Computed Tomography for assessing the relationship between tooth roots and the inferior alveolar canal.

OBJECTIVES: The purpose of this study is to compare Tuned-Aperture Computed Tomography (TACT) image sets made with linear vertical, linear horizontal, conical, and x-shaped x-ray projection arrays with regard to observer accuracy in (1) measuring the distance from the apex of a tooth root to the middle of the inferior alveolar canal (IAC), (2) measuring the shortest distance from the surface of a tooth root to the surface of the IAC, and (3) determining whether the root is buccal or lingual to the IAC. The same relationships were also examined by means of pairs of images and the buccal object rule. STUDY DESIGN: Two artificial mandible sections with simulated IACs were fabricated. The same human mandibular premolar root was used in both models to prevent development of learning cues to differentiate between models. The models were imaged from both sides, resulting in 4 orientations. An optical bench was designed to precisely orient different beam projection arrays for production of TACT image sets and pairs of images for use with the buccal object rule. Twelve dentists participated as observers to independently assess the relationships between the tooth root and the IAC with regard to the 4 orientations. RESULTS: For measuring the distance from the tooth apex to the middle of the IAC, TACT image sets made from conical and x-shaped arrays proved significantly more accurate than TACT image sets made from linear vertical or linear horizontal projections or pairs of digital images used with the buccal object rule (P <.05). For measuring the shortest distance between the tooth surface and the IAC surface, TACT image sets made from linear vertical, conical, and x-shaped projection arrays were significantly more accurate than measurements made through use of the buccal object rule or TACT image sets made through use of a linear horizontal projection array (P <.05). The following percentages of mistakes were made in determining whether the tooth root was buccal or lingual to the IAC: buccal object rule (58%), linear horizontal array (31%), linear vertical array (2%), conical array (0%), and x-shaped array (0%). CONCLUSIONS: For TACT, images acquired with conical and x-shaped beam projection arrays are preferred to those acquired with linear arrays for assessing the relationship between tooth roots and the IAC. TACT was found to be significantly more accurate than standard application of the buccal object rule for the relationships investigated.

Alveolar Process↗

Image resolution.

Explore the source record for details and available documents.

Data Display↗

The role of the dentist in detection of carotid atherosclerosis.

Cerebrovascular accidents (CVA), or stroke, afflict 731,000 Americans each year, with 165,000 of these individuals dying. Stroke is a major cause of death and disability throughout the world, including southern Africa. Atherosclerosis-related formation of thrombi and emboli at the bifurcation of the common carotid artery and proximal internal carotid artery represents a common cause of stroke. The detection of carotid atherosclerosis by dentists using panoramic radiographs recently has been presented to the public through television news stories and the press, but many dentists still do not know how to interpret panoramic radiographs for detection of this condition. This communication illustrates examples in which carotid atherosclerosis was detected using panoramic radiography. Differential diagnoses are presented. Since not every carotid plaque calcifies, panoramic radiography should never be used alone to exclude the possibility of carotid atherosclerosis. It should also be remembered that the mere presence of calcified carotid plaque is not necessarily a reflection on the degree of carotid stenosis. Definitive diagnosis and treatment requires referral of patients deemed to be at risk to an appropriate physician. A variety of advanced diagnostic methods, including gadolinium-enhanced MRI, Duplex Doppler sonography and angiography are used to confirm carotid stenosis.

Angiography↗

Evaluation of a new F speed dental X-ray film. The effect of processing solutions and a comparison with D and E speed films.

OBJECTIVE: To compare the properties of a new speed group F intra-oral X-ray film with those of three well established types both from groups D and E, and evaluate the impact of six commercially available processing solutions. METHODS: Four types of dental X-ray film, Flow (Flow X-ray, West Hempstead, NY, USA), speed group F, Ektaspeed Plus (Eastman Kodak, Rochester NY, USA) and M2 Comfort (AgfaGevaert, Morstel, Belgium), both speed group E, and Ultra-speed (Eastman Kodak), speed group D, were exposed under standardised conditions and processed in six different processing solutions. Base plus fog density, characteristic curves, film density, speed, average gradient, contrast and latitude and spatial resolution were calculated. RESULTS: The choice of processing chemistry affected radiographic characteristics including speed grouping. The new F film was consistently the fastest. M2 Comfort could achieve F speed and Ultra-speed achieved E speed using Automat XR chemicals. The speed of Ektaspeed Plus was independent of the automatic processing solution used. Ultra-Speed film had the lowest base plus fog density and the widest latitude. Film contrast was similar irrespective of the film and solution combination. CONCLUSIONS: The choice of processing chemistry can affect radiographic characteristics. The new F film reduces patient exposure by one-half compared with E speed film with no detriment to image quality.

Absorptiometry, Photon↗

Comparison of three intra-oral storage phosphor systems using subjective image quality.

OBJECTIVE: To compare the subjective image quality of three intra-oral storage phosphor systems. METHODS: DenOptix (Dentsply/Gendex, Chicago, IL, USA), Digora (Soredex, Helsinki, Finland), and CD-Dent (DigiDent Digital Imaging Technologies, Nesher, Israel) were compared. Two different imaging plates (IPs), BAS300 and HR300 (Fuji Photo Film Co., Tokyo, Japan) were used with the DenOptix system. The specimen was the maxilla and surrounding soft tissues of an adult cadaver. Imaging was at 70 kVp and 8 mA with a focus-detector distance of 38 cm using an optical bench. The exposure times were varied and a panel of five dentists independently evaluated the images produced with each system/IP receptor for seven features; proximal caries, gingival soft tissues, cortical bone, root canal space, root apices, periodontal ligament space and endodontic instrument clarity on a three-interval confidence scale. The best three exposures were chosen according to the highest scores for each system. These images were re-read in random order a total of 10 times. Pair-wise comparisons were made by use of odd's ratio analysis. A 95% confidence interval was applied. RESULTS: Images made with the DenOptix system/BAS IP combination were perceived to have the best overall image quality. The DenOptix/HR IP combination and Digora were rated almost equally in second place. The DigiDent system was ranked inferior. The Digora was considered to be the best for demonstrating gingival soft tissues (P < 0.05) and the DenOptix/HR300 combination the best for clarity of endodontic instruments (P < 0.05). CONCLUSIONS: While the DenOptix/BAS 300 combination was rated highest overall, the ranking of image quality by modality was found to be task-dependent. Digora was rated best for demonstrating gingival soft tissues.

Adult↗