PubMed HealthSearch

Biomedical subjects

A G Gordon

Publications and source records attributed to A G Gordon.

14 recordsLinked to original sources

Laparoscopic sterilization with the spring clip: instrumentation development and current clinical experience.

Since the original spring clip sterilization studies were reported, a number of clinically important modifications to the spring clip and applicator have been developed. The spring-loaded clip, manufactured by Richard Wolf Medical Instruments Corporation of Chicago, Illinois, and Rocket of London, Inc., London, England, and New York, New York can be applied with either a one- or two-incision applicator and the clips and applicators currently available incorporate improvements to the original prototypes in design, manufacture, and quality control. The two-incision applicator is associated with significantly fewer misapplications and the high pregnancy rates reported with the original clip and applicator have not occurred with the current designs. Comparative studies between the clip and band have revealed less operative bleeding and pain associated with the clip. The method is appropriate to all women requesting sterilization but especially to those in the younger age group who may subsequently request reversal because of divorce and remarriage.

Female

Mumps deafness.

Explore the source record for details and available documents.

Hearing Loss, Sudden

Menstrual patterns after laparoscopic sterilization using a spring-loaded clip.

Details of the menstrual cycles in 504 women were recorded before laparoscopic sterilization with a spring-loaded clip and at six months and one year after the procedure. The operation did not affect the length of the menstrual cycle or duration of menstrual flow, nor the patient's assessment of the amount of blood losss or the incidence of dysmenorrhoea. The previous method of contraception was significantly related to subsequent menstrual patterns.

Adult

Laparoscopic sterilization with spring-loaded clips: double-puncture technique.

The application of a spring-loaded clip to each fallopian tube using a second-incision clip applicator is a safe and effective method of laparoscopic sterilization. The operation is quick and easy to perform and is suitable for use with local anesthesia. The method avoids the dangers of hemorrhage, for the clip only alters 3 mm of the fallopian tube and does not transect the tube or mesosalpinx. No pregnancies have followed the sterilization procedure. An intrauterine pregnancy has occurred after a reversal procedure in one patient.

Abdomen

Perilymph fistula: a cause of auditory, vestibular, neurological and psychiatric disorder.

It is suggested that damage by mild trauma, viruses or bone disease to the otic capsule or to the membranes between the cochlea and the middle ear is common, and involved in many syndromes of obscure etiology. The clinical perilymph fistula (PF) syndrome can consist of any combination of the following: tinnitus, deafness, phonophobia, vertigo, ataxia, otalgia, facial palsy, headache, diplopia, blackouts, psychological distress. The following testable hypotheses are proposed: otitis media is due to perilymph in the middle ear, with secondary changes resulting from infection or inflammation: otosclerosis results from a slow leak in the presence of enzymes promoting bone growth: Meniere's syndrome follows reduced perilymph support for the endolymphatic system: Bell's palsy results from a perilymph provoked oedema in the bony facial nerve canal: PFs may be responsible for progressive rubella deafness, and for some cases of migraine, epilepsy, anxiety neurosis and hysteria: psychiatric sequelae of the PF syndrome predominate in the post-concussional syndrome and infantile autism: organisms can pass from the throat into the spinal fluid, causing meningitis or encephalitis. The tinnitus and vertigo are caused by random labyrinthine fluid movements, the headache and diplopia by reduced spinal fluid pressure.

Deafness