PubMed Health⌕ Search

Biomedical subjects

A G Gordon

Publications and source records attributed to A G Gordon.

At least 109 records · Page 6Linked to original sources

Laparoscopic sterilization with the spring clip: instrumentation development and current clinical experience.

Since the original spring clip sterilization studies were reported, a number of clinically important modifications to the spring clip and applicator have been developed. The spring-loaded clip, manufactured by Richard Wolf Medical Instruments Corporation of Chicago, Illinois, and Rocket of London, Inc., London, England, and New York, New York can be applied with either a one- or two-incision applicator and the clips and applicators currently available incorporate improvements to the original prototypes in design, manufacture, and quality control. The two-incision applicator is associated with significantly fewer misapplications and the high pregnancy rates reported with the original clip and applicator have not occurred with the current designs. Comparative studies between the clip and band have revealed less operative bleeding and pain associated with the clip. The method is appropriate to all women requesting sterilization but especially to those in the younger age group who may subsequently request reversal because of divorce and remarriage.

Female↗

Mumps deafness.

Explore the source record for details and available documents.

Hearing Loss, Sudden↗

Menstrual patterns after laparoscopic sterilization using a spring-loaded clip.

Details of the menstrual cycles in 504 women were recorded before laparoscopic sterilization with a spring-loaded clip and at six months and one year after the procedure. The operation did not affect the length of the menstrual cycle or duration of menstrual flow, nor the patient's assessment of the amount of blood losss or the incidence of dysmenorrhoea. The previous method of contraception was significantly related to subsequent menstrual patterns.

Adult↗

Laparoscopic sterilization with spring-loaded clips: double-puncture technique.

The application of a spring-loaded clip to each fallopian tube using a second-incision clip applicator is a safe and effective method of laparoscopic sterilization. The operation is quick and easy to perform and is suitable for use with local anesthesia. The method avoids the dangers of hemorrhage, for the clip only alters 3 mm of the fallopian tube and does not transect the tube or mesosalpinx. No pregnancies have followed the sterilization procedure. An intrauterine pregnancy has occurred after a reversal procedure in one patient.

Abdomen↗