PubMed HealthSearch

Biomedical subjects

A G Moore

Publications and source records attributed to A G Moore.

At least 19 recordsLinked to original sources

Age-related characteristics of ambulatory blood pressure load and mean blood pressure in normotensive subjects.

Ambulatory blood pressure monitoring has become increasingly popular for diagnosing and treating hypertension. However, data from normotensive subjects are needed for interpretation of hypertensive readings. Ambulatory blood pressure was monitored in 126 normotensive subjects (age range, 20 to 84 years). Mean systolic and diastolic blood pressure and blood pressure loads (percentage of systolic readings greater than 140 mm Hg and diastolic readings greater than 90 mm Hg) were obtained and interpreted. Mean awake systolic and diastolic pressures ranged from 125 +/- 10 to 137 +/- 17 mm Hg and 70 +/- 8 to 71 +/- 9 mm Hg, respectively. The systolic and diastolic trends of subjects' blood pressures taken during office visits and the 24-hour measurements were similar. Ranges for systolic and diastolic blood pressure loads from youngest to oldest ages were 9% +/- 14% to 25% +/- 20% and 3% +/- 7% to 4% +/- 7%, respectively. A comparison of blood pressure means from our sample that were taken during office visits and blood pressure means from a 2122-patient community survey demonstrated that our sample was reflective of an unselected population.

Adult

Antihypertensive effects of a new sustained-release formulation of nifedipine.

The blood pressure response to a new sustained-release formulation of nifedipine was evaluated in an 8-week, double-blind, placebo-controlled study. Twenty-nine patients with mild essential hypertension were randomized to receive placebo (N = 9), 30 mg nifedipine (N = 10), or 60 mg nifedipine (N = 10). During treatment, 30-mg and 60-mg doses of nifedipine administered once daily decreased office blood pressures from 137/98 +/- 8/2 mm Hg and 141/98 +/- 15/2 mm Hg at baseline, respectively, to 126/89 +/- 9/7 mm Hg and 126/86 +/- 6/7 mm Hg (P less than .005). Noninvasive automatic ambulatory blood pressure monitoring demonstrated a marginally significant (P less than .10) reduction in the mean 24-hour blood pressure of 2/6 +/- 8/8 mm Hg and 5/6 +/- 9/9 mm Hg for patients taking 30 mg and 60 mg nifedipine once daily, respectively. Diastolic blood pressure load (the percentage of ambulatory diastolic blood pressure readings greater than 90 mm Hg) during 24 hours was decreased by 41% and 35%, with 30 mg and 60 mg nifedipine administered once daily, respectively. No significant dose response to nifedipine at these dose levels was observed. Although the once-daily formulation of nifedipine achieved effective control of office blood pressure, similar control was not observed in awake and 24-hour periods in all patients.

Adult

Office blood pressures in supine, sitting, and standing positions: correlation with ambulatory blood pressures.

The variability of casual (office) blood pressure according to position at the time of measurement was investigated in 168 untreated patients with a history of mild to moderate essential hypertension. Two measurements were made in the supine, sitting, and standing positions on each of 2 consecutive days, and 24-hour ambulatory blood pressure monitoring was performed. The mean supine, sitting, and standing blood pressures were 146 +/- 15/91 +/- 7, 144 +/- 15/96 +/- 8, and 149 +/- 17/103 +/- 7 mm Hg, respectively. Diastolic blood pressures were significantly different from each other (P less than 0.0001). Supine and sitting systolic blood pressures were not different, but they were different from standing blood pressure (P less than 0.0001). The mean of all three positions (overall blood pressure) was 146 +/- 15/96 +/- 7 mm Hg. Supine, sitting, standing, and overall diastolic blood pressure means were 90 mm Hg or more in 88, 133, 164, and 133 patients, respectively. The mean awake ambulatory and 24-hour ambulatory blood pressures were 143 +/- 16/95 +/- 7 and 138 +/- 16/92 +/- 8 mm Hg, respectively, and diastolic blood pressures were 90 mm Hg or more in 121 and 88 patients, respectively. The correlation of office blood pressure with ambulatory blood pressure varied according to office position and was 0.76 to 0.82 (P less than 0.0001) for systolic blood pressure and 0.60 to 0.69 (P less than 0.0001) for diastolic blood pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Reproducibility of ambulatory blood pressure load.

Twenty-two hypertensive patients were monitored during two separate drug-free occasions with a Del Mar Avionics ambulatory device. Blood pressure loads (percentage of systolic and diastolic readings more than 140 and 90 mmHg, respectively) and mean BP were measured both to determine their reproducibility and to examine how they correlate with each other. The systolic and diastolic mean awake BPs for day 1 and day 2 were 140/93 mmHg and 140/91 mmHg, respectively, and BP loads were 45%/55% and 43%/54%. Moreover, mean BP loads correlated highly (r = 0.93) with mean BP values taken on the same day. Both ambulatory mean SBP and BP load were highly reproducible (r = 0.87 and 0.80, respectively, during the awake hours), and mean DBP and load were fairly reproducible (r = 0.59 and 0.39, respectively, during the awake hours). Clinically, however, both were consistent from day 1 to day 2. Mean and individual standard deviations also were reproducible for both systolic and diastolic pressures and loads.

Adult

Passive immunisation of children with bovine colostrum containing antibodies to human rotavirus.

The efficacy of a 10-day course of bovine colostrum with high antibody titre against the four known human rotavirus serotypes in protecting children against rotavirus infection was examined in patients admitted to hospital. Children aged 3 to 15 months were blocked in pairs according to ward accommodation (ie, isolation or open area). Each block contained 1 treated and 1 control child. The allocation to treatment or control (an artificial infant formula) was randomised. 9 of 65 control children but none of 55 treated children acquired rotavirus infection during the treatment period (p less than 0.001). The importance of protecting against rotavirus infection was highlighted by the fact that parents of symptomatic rotavirus-positive children sought medical attention seven times more often than did parents of symptomatic rotavirus-negative children (p less than 0.05).

Administration, Oral

Current practice in health promotion.

Progress in health promotion and preventive programme planning is limited by a lack of data on the development of current activities. A cross sectional survey of hospitals, community health centres, and other health agencies in New South Wales was therefore undertaken to determine the nature and extent of health promotion programmes being conducted in the period July to December 1983. A subsample of 1198 preventive programmes in child and family health was identified, making up 26% of all programmes operating in this period. Results indicate that three major types of programme are being conducted in child health. These are in the areas of (1) parent education and support, (2) school health education, including drug and alcohol education and personal development, and (3) child safety and first aid. Although the nature of these programmes generally corresponds with current thinking on what priorities in health promotion should be, results also indicate that evaluation of these programmes is limited. Most programmes assess only what participants think of the programme rather than assessing changes in knowledge, attitude, behaviour, or health status. Improvements in evaluation practice are required if preventive intervention programmes are to undertake seriously the task of altering the pattern of diseases and problems in childhood and adolescence.

Adolescent

An easily applied and removed dry annular suction electrode.

A new type of self-retaining dry metal electrode for the electrocardiogram (ECG) is described which adheres to the skin by the application of negative pressure to an annulus surrounding the electrode, which is a bare silver. Data are presented for the factors which govern the adherence to the skin and the range of initial impedance and the values obtained at 2, 5, 10 and 20 minutes and with tap water under the electrodes. The initial impedance is usually high (0.18 to 10 megohms) and decreases progressively with time. Tap water placed under the electrodes dramatically reduces the initial range of impedance. Such electrodes, when used with an amplifier with an adequately high input impedance, can be used for recording electrocardiograms in a variety of situations.

Electrocardiography

Electrical dose for ventricular defibrillation of large and small animals using precordial electrodes.

Electrical ventricular defibrillation of heavy subjects (over 100 kg body weight) is uncommon for the human or any animal species. This paper reports trans-chest ventricular defibrillation of subjects ranging in weight from 2.3 to 340 kg using conventional defibrillation current (heavily damped sine wave) of 0.3-30 ms duration. It was found that a body weight-to-electrical-shock strength relationship exists and can be expressed in terms of either electrical energy or peak current. For the duration of current pulse used clinically (3-10 ms), the relationship between energy requirement and body weight is expressed by the equation U = 0.73 W(1.52), where U is the energy in W.s and W is the body weight in kilograms. The current relationship is I = 1.87 W(0.88) where I is the peak current in amperes and W is the body weight in kilograms. The energy dose is somewhat more species and weight dependent and ranges from 0.5 to 10 W.s/kg (0.23-4.5 W.s/lb). The data obtained indicate that the peak current dose is virtually species and weight independent and is therefore a better indicator than energy for electrical defibrillation with precordial electrodes. In the duration range of 3-10 ms, the electrical dose is very nearly 1 A/kg of body weight (0.45 A/lb).

Animals