A new orthotic device in the non-operative treatment of idiopathic scoliosis.

A transverse force system, consisting of an anterior progression force counteracted by a posterior force and torque, acts on the vertebrae of a scoliotic spine. The aim of the newly introduced TriaC brace is to reverse this transverse force pattern by externally applied and constantly present orthotic forces. In the frontal plane the force system in the TriaC brace is in accordance with the force system of the conventional braces. However, in the sagittal plane the force system acts only in the thoracic region. As a result, there is no pelvic tilt, and it provides flexibility without affecting the correction forces during body motion. In the current preliminary study it is demonstrated that the brace prevents further progression of the Cobb angle and axial rotation in idiopathic scoliosis. The new brace has the added advantage of comfort for the wearer, and it offers a better cosmetic appearance, as well as, potentially, a better compliance.

Braces↗

On the determination of the angular orientation of a vertebra.

In this paper we consider the spatial orientation of vertebrae. We take the view that, in determining their rotation angles from X-rays, the procedure applied by Drerup yields the most reliable empirical results, viz. the three angles through which a vertebra rotates about its own symmetry axes in a specific sequence. With a view to the further use of this information to analyze deformations or the motion of a spine we recommend that the Drerup angles be converted into the well-known Eulerian angles. How this can be done is the subject of this report.

Algorithms↗

Improving the fixation of an artificial intervertebral disc.

The fixation of an artificial intervertebral disc has been studied especially with respect to the dimensions, the convexity of the endplates and the size of the fixation elements. From literature and cadaveric vertebrae, the dimensions and shape of the lumbar vertebral endplates were determined and the dimensions of fixation ribs for the artificial intervertebral disc were calculated. To withstand shear forces and prevent dislocation, two sagittal ribs, each 3.5 mm in height and at least 20 mm in length and four transversal ribs, each 1.5 mm in height and with a total length of 60 mm are sufficient. A range of five different sagittal diameters was selected as sufficient for all patients. At least 72.6 % of the endplate of the vertebrae is covered. A convexity with a radius of 140 mm limits the gap to 0.62 mm.

Biomechanical Phenomena↗

Scoliosis correction with shape-memory metal: results of an experimental study.

The biocompatibility and functionality of a new scoliosis correction device, based on the properties of the shape-memory metal nickel-titanium alloy, were studied. With this device, the shape recovery forces of a shape-memory metal rod are used to achieve a gradual three-dimensional scoliosis correction. In the experimental study the action of the new device was inverted: the device was used to induce a scoliotic curve instead of correcting one. Surgical procedures were performed in six pigs. An originally curved squared rod, in the cold condition, was straightened and fixed to the spine with pedicle screws. Peroperatively, the memory effect of the rod was activated by heating the rod to 50 degrees C by a low-voltage, high-frequency current. After 3 and after 6 months the animals were sacrificed. The first radiographs, obtained immediately after surgery, showed in all animals an induced curve of about 40 degrees Cobb angle - the original curve of the rod. This curve remained constant during the follow-up. The postoperative serum nickel measurements were around the detection limit, and were not significantly higher compared to the preoperative nickel concentration. Macroscopic inspection after 3 and 6 months showed that the device was almost overgrown with newly formed bone. Corrosion and fretting processes were not observed. Histologic examination of the sections of the surrounding tissues and sections of the lung, liver, spleen and kidney showed no evidence of a foreign body response. In view of the initiation of the scoliotic deformation, it is expected that the shape-memory metal based scoliosis correction device also has the capacity to correct a scoliotic curve. Moreover, it is expected that the new device will show good biocompatibility in clinical application. Extensive fatigue testing of the whole system should be performed before clinical trials are initiated.

Alloys↗

Requirements for an artificial intervertebral disc.

Intervertebral disc degeneration is an important social and economic problem. Presently available artificial intervertebral discs (AIDs) are insufficient and the main surgical intervention is still spinal fusion. The objective of the present study is to present a list of requirements for the development of an AID which could replace the human lumbar intervertebral disc and restore its function. The list addresses geometry, stiffness, range of motion, strength, facet joint function, center of rotation, fixation, failsafety and implantation technique. Date are obtained from the literature, quantified where possible and checked for consistency. Existing AIDs are evaluated according to the presented list of requirements. Endplate size is a weak point in existing AIDs. These should be large and fit vertebral bodies to prevent migration. Disc height and wedge angle should be restored, unless this would overstretch ligaments. Finally, stiffness and range of motion in all directions should equal those of the healthy disc, except for the axial rotation to relieve the facet joints.

Biomechanical Phenomena↗

The geometry of the human paraspinal muscles with the aid of three-dimensional computed tomography scans and 3-Space Isotrak.

STUDY DESIGN: Accurate determination of the three-dimensional coordinates of paraspinal muscles is presented. OBJECTIVES: To determine the precise position and the size of the paraspinal muscles. SUMMARY OF BACKGROUND DATA: The accurate measurements of the muscle moment arms are important in the evaluation of computer models for spinal movement. It has been reported that a change in the modelling of the erector spinae muscles can alter the compressive forces in the spinal column by 20% and can increase the offsetting shear forces. Classic studies used measurements from cross-sectional anatomic diagrams of human cadavers, scaled to the width and depth of the trunk of the subject, to calculate the moment that produces the joint torque. METHODS: Computed tomography scans of two male cadavers provided data on the bony elements. Three-dimensional coordinates of the origins and insertions of the muscle-fascicles of the paraspinal muscles were obtained with the use of 3-Space Isotrak equipment. The bony and muscle coordinates were combined in the ANSYS (version 5.4; Swanson Analysis Systems, Canonsberg, PA) program. RESULTS: Results of this combination and the three-dimensional coordinates of the paraspinal muscles as acquired by the 3-Space Isotrak are given. CONCLUSION: The position and the moment arms of paraspinal muscles were accurately determined. This is important for further evaluation of mathematical models.

Aged↗

Curve progression and spinal growth in brace treated idiopathic scoliosis.

The risk of progression of idiopathic scoliosis is correlated primarily to factors that predict potential remaining skeletal growth. The aim of the current study was to evaluate spinal growth, measured as the length of the scoliotic spine on serial longitudinal radiographs, and its relationship to progression of the scoliotic curve. The retrospective study was based on measurements made on standing anteroposterior radiographs of 60 patients with adolescent idiopathic scoliosis. In all patients, a Boston brace was prescribed during the followup period. Despite brace treatment, a significantly greater average progression rate of the scoliotic curve was seen in periods of rapid to moderate growth (> or = 10 mm per year) compared with periods of small or no growth (< 10 mm per year). The difference in progression rates concerned the increase of the Cobb angle and the increase of lateral deviation and axial rotation. These findings indicate the length of the spine measured on subsequent radiographs is an excellent parameter to determine spinal growth and thus an excellent predictor of scoliosis progression. With the presented growth charts, which were derived from the measured individual growth velocity values of the patients in the study, it is possible to predict future spinal growth at different chronologic ages.

Adolescent↗

A biomechanical analysis of the vertebral and rib deformities in structural scoliosis.

Although the structural changes occurring in the scoliotic spine have been reported as early as the 19th century, the descriptions and biomechanical explanations have not always been complete and consistent. In this study, three-dimensionally rendered CT images of two human skeletons with a scoliotic deformity and two patients with serious scoliosis were used to describe the intrinsic vertebral and rib deformities. The pattern of structural deformities was found to be consistent. Apart from the wedge deformation of the apical vertebrae, a rotation deformity was found in the transversal plane between the vertebral body and the posterior complex: the vertebral body was maximally rotated towards the convexity of the scoliotic curve, whereas the tip of the spinous process was pointed to posterior. The rib deformities at the convex side of the scoliotic curve showed an increased angulation of the rib at the posterior angle, whereas the rib curve on the concave side was flattened. The observed vertebral deformities suggest that these are caused by bone remodelling processes due to forces in the anterior spinal column, which drive the apical vertebral body out of the midline, whereas forces of the musculo-ligamentous structures at the posterior side of the spinal column attempt to minimize the deviations and rotations of the vertebrae. The demonstrated rib deformities suggest an adaptation to forces imposed by the scoliotic spine.

Biomechanical Phenomena↗

Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy.

The nearly equiatomic nickel-titanium (NiTi) alloy is known for its shape memory properties. These properties can be put to excellent use in various biomedical applications, such as wires for orthodontic tooth alignment and osteosynthesis staples. The aim of this study was to evaluate the short-term biological safety of the NiTi alloy. We carried out an end-point dilution minimal essential medium (MEM) extract cytotoxicity test, a guinea-pig sensitization test and two genotoxicity tests: the Salmonella reverse mutation test and the chromosomal aberration test. The NiTi alloy showed no cytotoxic, allergic or genotoxic activity, similar to the clinical reference control material AISI 316 LVM stainless steel. This promising biological behaviour was most likely due to a minimal release of ions and in that way a reflection of the good corrosion resistance of the NiTi alloy. Given these very good results, together with the good tissue compatibility as shown in several implantation studies in the literature, the NiTi alloy can be regarded as a biologically safe implant material with many promising clinical applications.

Alloys↗

[Vertebral osteomyelitis in an infant].

Neonatal osteomyelitis is uncommon. The disease starts often without signs of infection and may lead to severe complications. A case is reported of a neonate with vertebral osteomyelitis of the cervical vertebrae. Difficulties of diagnosing the disease and several therapeutic regimes proposed in the literature are discussed.

Anti-Bacterial Agents↗

Bilateral total hip and knee replacement in rheumatoid arthritis patients.

Between 1978 and 1983, 14 patients suffering from rheumatoid arthritis were treated by bilateral total hip and knee replacement. At the time of this follow-up study (32-92 months postoperatively) one patient had died of concomitant disease and was excluded. The postoperative results regarding pain relief, improvement in performing daily activities, and function were studied in the remaining 13 patients. A 200-point rating scale was used, which compared the pre- and postoperative findings at follow-up. All patients showed marked relief from pain, good function and a good functional score. Although walking ability did not always improve, all patients were enthusiastic.

Activities of Daily Living↗

Kinematics of the scoliotic spine as related to the normal spine.

A coupling between the lateral flexion and axial rotation as a result of the geometric arrangement of the motion segments is well known in a normal spine. The kinematic behavior of idiopathic scoliotic spines has been analyzed by means of a biomechanical model study and a radiologic study. The anteroposterior and lateral flexion radiographs of 40 patients with progressive adolescent idiopathic scoliosis were studied. In five of these patients, anteroposterior radiographs were also made with the spine in a ventrally flexed position. The kinematic behavior of a nonpathologic spine was examined by means of a three-dimensional, nonlinear geometric mathematical model of the spine. The frontal plane inclination of the facet joints in conjunction with the vertebral orientation in the sagittal plane influence the kinematic behavior in the normal spine. In a scoliotic spine, there is an axially rotated position and, in most cases, a dorsal inclination (lordotic) of the motion segments. Nevertheless, the direction of the axial rotation during lateral flexion does not differ from the direction of the axial rotation during lateral flexion in a normal spine. The existing axial rotation in idiopathic scoliosis cannot be explained on the basis of spinal kinematics. In contrast to normal spines, in scoliotic spines exists a coupling between ventral flexion or extension and axial rotation. This may be essential in the management of idiopathic scoliosis.

Adolescent↗